Third Order Intermodulation Distortion Troubleshooting

Related Adjustments

  • None

If TOI fails to meet specifications, suspect the A13 Front End Assembly. Next suspect the A2 Analog IF Assembly.

TOI is tested using low pass filters in Lowband. The low pass filters are used to reduce the second harmonic of the signal source. If a failure occurs in Lowband, the filters may be suspect.