Property (Read-Write)
SCPI.TRIGger.TR(Ch).WIDE.VIDeo.FREQuency.WIDTh = Value
Value = SCPI.TRIGger.TR(Ch).WIDE.VIDeo.FREQuency.WIDTh
This command sets/gets wide video trigger frequency span, for the selected channel Ch.
Parameter |
Value |
Description |
Wide video trigger frequency span |
Data Type |
Double precision floating point type (Double) |
Range |
0 ~ 5.28G |
Preset Value |
880M |
Unit |
Hz |
Resolution |
- |
Preset Effect |
Yes |
Save-Recall Effect |
Yes |
Error |
- |
Dim Var as Double
Var= 0
SCPI.TRIGger.TR1.WIDE.VIDeo.FREQuency.WIDTh = Var
Var = SCPI.TRIGger.TR1.WIDE.VIDeo.FREQuency.WIDTh
SCPI.TRIGger.TR(Ch).WIDE.VIDeo.FREQuency.CENTer
No equivalent key is available on the front panel.
:TRIGger:TR[1-1]:WIDE:VIDeo:FREQuency:WIDTh {0 ~ 5.28G}
:TRIGger:TR[1-1]:WIDE:VIDeo:FREQuency:WIDTh?
{0 ~ 5.28G} <newline><^END>
10 OUTPUT 717;":TRIGger:TR1:WIDE:VIDeo:FREQuency:WIDTh 0"
20 OUTPUT 717;":TRIGger:TR1:WIDE:VIDeo:FREQuency:WIDTh ?"
30 ENTER 717;A