CALCulate:MEASure:Phase Commands

Defines the settings for phase reference.

CALCulate:MEASure:Phase

| PREFerence

| AUTO

| FREQuency

| XPOSition

| XSPan

| XREFerence

| XPOSition

| XSPan

  

 


CALCulate:MEASure<mnum>:PHASe:PREFerence:AUTO  <Boolean>

Applicable Models: E505xA with opt S96301xB

(Read-Write)  Enable and disable the auto phase reference frequency.

Parameters

 

mnum

Measurement number for each measurement.

<Boolean>

Choose from:

OFF / 0: set the Phase Reference Frequency manually (Set frequency to)

ON / 1:  set the Phase Reference Frequency automatically (Measure Frequency at)

Examples

CALC:MEAS2:PHAS:PREF:AUTO OFF

calculate:measure2:phase:preference:auto off

Query Syntax

CALCulate:MEASure<mnum>:PHASe:PREFerence:AUTO?

Return Type

Boolean

Default

OFF


CALCulate:MEASure<mnum>:PHASe:PREFerence:FREQuency  <value>

Applicable Models: E505xA with opt S96301xB

(Read-Write)  Set and read the "Set Frequency to" setting in the phase reference frequency.

Parameters

 

mnum

Measurement number for each measurement.

<value>

Phase reference frequency

Examples

CALC:MEAS2:PHAS:PREF:FREQ 1E6

calculate:measure2:phase:preference:frequency

Query Syntax

CALCulate:MEASure<mnum>:PHASe:PREFerence:FREQuency?

Return Type

Numeric

Default

1E9


CALCulate:MEASure<mnum>:PHASe:PREFerence:XPOSition  <value>

Applicable Models: E505xA with opt S96301xB

(Read-Write)  Set and read the "Measure frequency at" setting in the phase reference frequency.

Parameters

 

mnum

Measurement number for each measurement.

<value>

Phase reference in sec

Examples

CALC:MEAS2:PHAS:PREF:XPOS 0.0001

calculate:measure2:phase:preference:xposition 0.0001

Query Syntax

CALCulate:MEASure<mnum>:PHASe:PREFerence:XPOSition?

Return Type

Numeric

Default

0


CALCulate:MEASure<mnum>:PHASe:PREFerence:XSPan  <value>

Applicable Models: E505xA with opt S96301xB

(Read-Write)  Set and read the "Using Span of" setting in the phase reference frequency.

Parameters

 

mnum

Measurement number for each measurement.

<value>

Phase span in sec

Examples

CALC:MEAS2:PHAS:PREF:XSP 0.001

calculate:measure2:phase:preference:xspan 0.001

Query Syntax

CALCulate:MEASure<mnum>:PHASe:PREFerence:XSPan?

Return Type

Numeric

Default

0


CALCulate:MEASure<mnum>:PHASe:XREFerence:XPOSition  <value>

Applicable Models: E505xA with opt S96301xB

(Read-Write)  Set and read the "Phase to Zero at" setting in the phase zero position.

Parameters

 

mnum

Measurement number for each measurement.

<value>

Phase zero position in sec

Examples

CALC:MEAS2:PHAS:XREF:XPOS 0.001

calculate:measure2:phase:xreference:xposition 0.0001

Query Syntax

CALCulate:MEASure<mnum>:PHASe:XREFerence:XPOSition?

Return Type

Numeric

Default

0


CALCulate:MEASure<mnum>:PHASe:XREFerence:XSPan  <value>

Applicable Models: E5055x with opt S96301xB

(Read-Write)  Set and read the "Using Span of" setting in the phase zero position.

Parameters

 

mnum

Measurement number for each measurement.

<value>

Span in sec

Examples

CALC:MEAS2:PHAS:XREF:XSP 1e-4

calculate:measure2:phase:xreference:xspan 1e-4

Query Syntax

CALCulate:MEASure<mnum>:PHASe:XREFerence:XSPan?

Return Type

Numeric

Default

0