1. System Requirements

Installation Steps: 1 2 3 4 5 6 7

To generate signals using the N7610C Signal Studio for IoT 2025 software, you must have a properly configured PC and a properly configured instrument, as described in the following tables.

Hardware Requirements

Instruments

Requirements

N5186A MXG vector signal generator

Firmware:

  • Version A.13.00 or later

N5172B EXG X-Series RF vector signal generator

Firmware:

  • Version B.01.70 or later

Required options:

  • N5172B-503 (9 kHz to 3 GHz frequency range)

  • N5172B-653 (internal baseband generator, 32 Msa/s, up to 60 MHz RF bandwidth)

Recommended options:

  • N5172B-009 (internal Flash drive)

N5182B MXG X-Series RF vector signal generator

Firmware:

  • Version B.01.70 or later

Required options:

  • N5182B-503 (9 kHz to 3 GHz frequency range)

  • N5182B-656 (internal baseband generator, 32 Msa/s, up to 80 MHz RF bandwidth)

Recommended options:

  • N5182B-009 (internal Flash drive)

N5166B CXG RF vector signal generator

Firmware:

  • Version B.01.80 or later

E8267D PSG vector signal generator

Firmware:

  • Version C.06.26 or later

Required options:

  • E8267D-513 (250 kHz to 13 GHz frequency range)

  • E8267D-602 (internal baseband generator with 64 Msa memory and digital bus capability)

Recommended options:

  • E8267D-005 (6 GB internal hard drive)

M9381A PXIe vector signal generator

Driver:

  • Version 1.4.400.0 or later

Recommended options:

  • M9381A-F03 (1 MHz to 3 GHz frequency range)

  • M9381A-B04 (RF modulation bandwidth 40 MHz)

  • M9381A-M01 (memory 32 Msa)

  • M9381A-300 (adds M9300A PXIe frequency reference, if one is not already in the system)

Limitations:

The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:

  • Set ALC to On whenever possible. This avoids the automatic Power Search.

  • When ALC must be set to Off (or is set to Off by Signal Studio), you can re-trigger the signal by turning ARB Off, then On, and then send the trigger signal to M9381A VSG.

For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization.

M9383B VXG-m microwave signal generator

Firmware:

  • Version A.02.00 or later

Recommended options:

  • M9383B-001 (add channel 1)

  • M9383B-F44 (frequency range, 1 MHz to 44 GHz)

  • M9383B-D21 (RF bandwidth, 2 GHz with 256 MSa memory for frequency options F32 and F44)

  • M9383B-M05 (baseband generator memory upgrade to 512 MSa)

M9384B VXG microwave signal generator

Firmware:

  • Version A.02.00 or later

Recommended options:

  • M9384B-001 (add channel 1)

  • M9384B-F44 (frequency range, 1 MHz to 44 GHz)

  • M9384B-D21 (RF bandwidth, 2 GHz with 256 MSa memory for frequency options F32 and F44)

  • M9384B-M05 (baseband generator memory upgrade to 512 MSa)

M9484C VXG signal generator

Firmware:

  • Version A.10.00 or later

M9410A VXT PXI vector transceiver

For information on software and available options, go to www.keysight.com/find/m9410a

M9411A VXT PXI vector transceiver

For information on software and available options, go to www.keysight.com/find/m9411a

M9415A VXT PXI vector transceiver

For information on software and available options, go to www.keysight.com/find/m9415a

PC Requirements

200 GB HDD with 2 GB free disk space at runtime (5 GB or higher recommended)

1024 x 768 screen resolution (1280 x 1024 recommended)

If you use a high-resolution display, the GUI's font size may appear too small to read. To resolve this, lower your PC's display resolution, but make sure the display scaling remains set at 100 percent, otherwise portions of the GUI will become truncated and hidden from view.

Windows 11 (64 bit)

Windows 10 (64 bit):

Microsoft .NET Framework 4.5.2 or later

Keysight IO Libraries, version 18.0 or later

Keysight License Manager 5 (4. Downloading and Installing Keysight License Manager 5)

Keysight License Service (included with installer)

Keysight Host Processor Platform (included with installer)

Installed GPIB IO interface card, LAN interface card, or USB/GPIB interface connector

Keysight VISA

Microsoft Windows Installer version 2.0 or later