Last updated: January 16, 2009
This section is only applicable to the lab application.
Cell 2 Primary Scrambling Code
=
Intra Freq 2nd Cell Scrambling Code
When ordered to perform a soft handover with a cell, some UEs require that they have previously measured the cell before handing off to it. When the UE is directed to perform measurements on the neighbor cells specified in SIB 11 (see SIB11 Cell Info List ), it should also report measurement results for any other detected cells not on the neighbor list. However some UEs may require that the cell be in the neighbor list in order to perform measurements on it. Thus, some UES require that cell 2 be in the neighbor list for soft handover to be successful.
Cell 2 Power
is on, but no
Mobile Station Reported Pilot Level Information
is being displayed for
Cell 2
To aid in the UE's detection of cell 2, ensure that cell 2's primary scrambling code is included in the intra frequency neighbor cell list (see Cell 2 Overview and SIB11 Cell Info List ), and that cell 2's power is high enough to be detected (you may need to set it to a value higher than cell 1).