Real Time

1. System Requirements

Installation Steps: 1 2 3 4 5 6 7

To generate signals using the N7610B Signal Studio for Short Range Communications software, you must have a properly configured PC and a properly configured instrument, as described in the following tables.

Hardware Requirements

Instruments

Requirements

N5172B EXG X-Series RF vector signal generator

Firmware revision B.01.10 or later (how to upgrade

Required options:

N5172B-503 (9 kHz to 3 GHz frequency range)

N5172B-653 (Internal baseband generator, 32 MSa/sec, up to 60 MHz RF bandwidth)

Recommended options:

N5172B-009 (internal Flash drive)

N5182B MXG X-Series RF vector signal generator

Firmware revision B.01.10 or later (how to upgrade)

Required options:

N5182B-503 (9 kHz to 3 GHz frequency range)

N5182B-656 (Internal baseband generator, 32 MSa/sec, up to 80 MHz RF bandwidth)

Recommended options:

N5182B-009 (internal Flash drive)

N5182A MXG RF vector signal generator

Firmware revision A.01.20 or later (how to upgrade)

Required options:

N5182A-503 (9 kHz to 3 GHz frequency range)

N5182A-651 (Internal baseband generator, 30 MSa/sec, up to 24 MHz RF bandwidth )

Recommended options:

N5182A-019 (Increase Baseband Generator Memory to 64MSa)

E4438C ESG vector signal generator

Firmware revision C.04.95 or later (how to upgrade)

Required options:

E4438C-503 (250 kHz to 3 GHz frequency range)

E4438C-601 (internal baseband generator with 8 Msample memory and digital bus capability)

Recommended options:

E4438C-602 (internal baseband generator with 64 Msample memory and digital bus capability)

E8267D PSG vector signal generator

Firmware revision C.04.92 or later (how to upgrade)

Required options:

E8267D-520 (250 kHz to 20 GHz frequency range)

E8267D-602 (internal baseband generator with 64 Msample memory and digital bus capability)

Recommended options:

E8267D-005 (6 GB internal hard drive)

M9381A PXIe vector signal generator

Driver version: 1.4.400.0 or later

Required options:

M9381A-F03 (1 MHz to 3 GHz frequency range)

M9381A-B04 (40 MHz modulation bandwidth)

M9381A-M01 (32 MSa memory)

M9381A-300 (add M9300A PXIe frequency reference)

Limitations:

The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:

  • Set ALC to On whenever possible. This avoids the automatic Power Search.
  • When ALC must be set to Off (or is set to Off by Signal Studio), you can re-trigger the signal by turning ARB Off, then On, and then send the trigger signal to M9381A VSG.

For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization.

PC Requirements

200 GB HDD with 2 GB free disk space at runtime (5 GB or higher recommended)

1024 x 768 screen resolution (1280 x 1024 recommended)

Windows 7 (Professional/Ultimate/Enterprise)1,2:

Windows XP Service Pack 3 or later (Professional)

Installed GPIB IO interface card, LAN interface card, or USB/GPIB interface connector

Keysight VISA

Microsoft Windows Installer version 2.0 or later


1 No support for Itanium64.

2 Signal Studio is compatible with the 64-bit operating system, but performs at the 32-bit speed.