Search Length (TEDS)

Default: Normal Uplink: 55mSec
Normal Downlink: 30mSec
Random Access and Control Uplink: 35mSec
(See Using Standard Setups/Presets)

Range: from default value to recording/sample maximum

Search Length specifies the length of the captured signal you want to use for searching for particular signal characteristics.

The Search Length minimums depend on the selections for the PvT Off Analysis Time (Pre and Post). The table below shows the Search Length minimums for the Pre/Post times set to the defaults and for Pre/Post times set to zero:

Search Length minimums

Slot Formats

Pre/Post = defaults

Pre/Post = 0

Normal Uplink

24.167mSec

14.167mSec

Normal Downlink

14.167mSec

14.167mSec

Random Access

17.083mSec

7.083mSec

Control Uplink

17.083mSec

7.083mSec

Increasing Search Length decreases measurement update rate.

See Also

Analysis Tab

Format Tab