Search Length (TEDS)
Normal
Uplink: 55mSec
Normal
Downlink: 30mSec
Random
Access and Control Uplink: 35mSec
(See
Using Standard Setups/Presets)
from default value to recording/sample maximum
specifies the length of the captured signal you want to use for searching for particular signal characteristics.
The minimums depend on the selections for the PvT Off Analysis Time (Pre and Post). The table below shows the Search Length minimums for the Pre/Post times set to the defaults and for Pre/Post times set to zero:
|
Slot Formats |
Pre/Post = defaults |
Pre/Post = 0 |
|---|---|---|
|
Normal Uplink |
24.167mSec |
14.167mSec |
|
Normal Downlink |
14.167mSec |
14.167mSec |
|
Random Access |
17.083mSec |
7.083mSec |
|
Control Uplink |
17.083mSec |
7.083mSec |
Increasing decreases measurement update rate.