| (Read-Write) Set and query search count auto state. Note: Search count indicates the number of displayed channel on FieldFox screen. | |
| Relevant Modes | |
| Couplings | Only available when in Custom List or EMF Custom List scan mode. | 
| Parameters | 
 | 
| <bool> | Search count AUTO ON | OFF state. Choose from: 0 or OFF - Search count AUTO OFF for user to input search count values. The Search Count Auto will automatically switch to OFF when the Search Count value is set. See :CHSCanner:SEARch:COUNt. 1 or ON - Search count AUTO ON to enable auto search count. | 
| Examples | :CHSC:SEAR:COUN:AUTO 1 */Sets the search count auto to ON :CHSC:SEAR:COUN:AUTO OFF */Sets the search count auto to OFF and in USER mode. Search count default value is 2 if more than 1 channel setting in the List | 
| Query Syntax | :CHSC:SEAR:COUN:AUTO? */queries the search count auto state | 
| Return Type | boolean | 
| Default | ON or 1 | 