Click here to view links to Setup commands for all Measurement Classes.
| Main Tab Commands | |||
| Softkey | Sub-item | SCPI |
COM |
| Sweep Setup... | Sweep Type | ||
| Linear Frequency | SENSe:SWEep:TYPE | ||
| Log Frequency | SENSe:SWEep:TYPE | ||
| Power Sweep | SENSe:SWEep:TYPE | ||
| CW Time | SENSe:SWEep:TYPE | ||
| Segment Sweep | SENSe:SWEep:TYPE | ||
| Phase Sweep | SENSe:SWEep:TYPE | ||
| Sweep Properties | |||
| Start | SENSe:FREQuency:STARt | ||
| Stop | SENSe:FREQuency:STOP | ||
| Power | SOURce:POWer[:LEVel][:IMMediate][:AMPLitude] | ||
| Points | SENSe:SWEep:POINts | ||
| IF Bandwidth | SENSe:BWIDth[:RESolution] | ||
| Start Power | SOURce:POWer:STARt | ||
| Stop Power | SOURce:POWer:STOP | ||
| CW Freq | SENSe:FREQuency[:CW] | ||
| Segment Table | |||
| X-axis Point Spacing | SENSe:SEGMent:X:SPACing | ||
| Allow arbitrary Segments | SENSe:SEGMent:ARBitrary | ||
| Display Center/Span Freq | SENSe:SEGMent:FREQuency:CENTer SENSe:SEGMent:FREQuency:SPAN | ||
| Timing | |||
| Sweep Time | SENSe:SWEep:TIME | ||
| Dwell Time | SENSe:SWEep:DWELl | ||
| Sweep Delay | SENSe:SWEep:DWELl:SDELay | ||
| Auto Sweep Time | SENSe:SWEep:TIME:AUTO | ||
| Fast Sweep - Reduce settling time | SENSe:SWEep:SPEed | ||
| Sweep Mode | SENSe:SWEep:GENeration | ||
| Sweep Sequence | SENSe:SWEep:GENeration:POINtsweep | ||
|
Meas Class... |
CALCulate:MEASure:DEFine | ||
| Quick Start... | S-Param | CALCulate:MEASure:PARameter | |
| Balanced | CALCulate:MEASure:PARameter | ||
| Other | CALCulate:MEASure:PARameter | ||
| Layout Tab Commands | |||
| Softkey | Sub-item | SCPI |
COM |
| New Trace | DISPlay:WINDow:TRACe[:STATe] | ||
| New Channel | None | ||
| New Window | DISPlay:WINDow[:STATe] | ||
| New Sheet | DISPlay:SHEet:STATe | ||
| Delete | TrN | DISPlay:WINDow:TRACe:DELete | |
| ChN | SYSTem:CHANnels:DELete | ||
| WinN | DISPlay:WINDow[:STATe] | ||
| Select | TrN | DISPlay:WINDow:TRACe:SELect | |
| ChN | None | ||
| WinN | DISPlay:WINDow:TRACe:SELect | ||
| Measure... | S-Parameter | CALCulate:MEASure:PARameter | |
| Balanced | CALCulate:MEASure:PARameter | ||
| Receivers | CALCulate:MEASure:PARameter | ||
| Meas Class... | CALCulate:MEASure:DEFine | ||
| Internal Hardware Tab Commands | |||
| Softkey | Sub-item | SCPI |
COM |
|
Receiver Gain |
|||
|
Enable Interface Control |
|||
|
Channel |
None |
||
|
Channel Control Label |
None |
||
|
Before Sweep Start |
|||
|
Enable Control |
None |
||
|
Handler I/O Control |
|||
|
Test Set I/O Control (addr. data) |
|||
|
Dwell After Command |
None |
||
|
Aux I/O Output Voltage |
|||
|
After Sweep End |
|||
|
Enable Control |
None |
||
|
Handler I/O Control |
|||
|
Test Set I/O Control (addr. data) |
|||
|
Dwell After Command |
None |
||
|
Aux I/O Output Voltage |
|||
|
Reset All |
|||
|
Save |
None |
||
|
Recall |
|||
|
Reference In |
|
||
|
Internal/External |
|
||
|
Softkey |
Sub-item |
SCPI |
COM |
|
External Device... |
New |
||
|
Remove |
|||
|
Name |
|||
|
Device Type |
|||
|
Driver |
|||
|
Active - Show in UI |
|||
|
DC Meter |
|||
|
Timeout |
None |
||
|
Dwell Before Sweep |
|||
|
Dwell After Point Set |
|||
|
Type |
|||
|
Receiver Correction On |
|||
|
Offset |
|||
|
Scaling |
|||
|
|
|||
|
ID Query |
|||
|
Error Query |
|||
|
Enable I/O |
|||
|
Disable I/O |
|||
|
Before Sweep |
|||
|
After Sweep |
|||
|
Abort Sweep |
|||
|
Point Set Commands |
|||
|
DC Source |
|||
|
Timeout |
None |
||
|
Dwell Before Sweep |
|||
|
Dwell After Point Set |
|||
|
Type |
|||
|
|
|||
|
|
|||
|
|
|||
|
ID Query |
|||
|
Error Query |
|||
|
Enable I/O |
|||
|
Disable I/O |
|||
|
Read Max Using |
|||
|
Define Max As |
|||
|
Read Min Using |
|||
|
Define Min As |
|||
|
Before Sweep |
|||
|
After Sweep |
|||
|
Abort Sweep |
|||
|
Point Set Commands |
|||
|
Hybrid Source |
|||
|
Input Source Carrier Frequency |
SYSTem:CONFigure:EDEVice:SOURce:HYBRid:INPut:FREQuency:CARRier |
||
|
Input Multiplier |
SYSTem:CONFigure:EDEVice:SOURce:HYBRid:INPut:FREQuency:MULTiplier |
||
|
Input Source Name |
|||
|
Input Source Power Limit |
|||
|
Enable Pulse (Input) |
|||
|
LO Multiplier |
SYSTem:CONFigure:EDEVice:SOURce:HYBRid:LO:FREQuency:MULTiplier |
||
|
LO Source Name |
|||
|
LO Power |
|||
|
Enable Pulse (LO) |
|||
|
Lock Dependent Sources |
|||
|
Freq Max (SSB Mixer) |
|||
|
Freq Min (SSB Mixer) |
|||
|
Gain (SSB Mixer) |
|||
|
Equation (SSB Mixer) |
SYSTem:CONFigure:EDEVice:SOURce:HYBRid:OUTPut:MIXer:SIDeband |
||
|
Hybrid Type |
|||
|
Power Meter |
|||
|
Sensor A/B |
None |
||
|
Tolerance |
|||
|
Max Number of Readings |
|||
|
Use Loss Table |
|||
|
Edit Table |
SOURce:POWer:CORRection:COLLect:TABLe:POINts? |
||
|
Uncertainty... |
SYSTem:CONFigure:EDEVice:PMAR:UNCertainty:CATalog? SYSTem:CONFigure:EDEVice:PMAR:UNCertainty:FILE SYSTem:CONFigure:EDEVice:PMAR:UNCertainty:MODel |
||
|
Pulse Generator |
|||
|
Time out |
|||
|
Primary Mode |
|||
|
Output |
|||
|
High |
|||
|
Low |
|||
|
Source Imp |
|||
|
Load Imp |
|||
|
SMU |
|||
|
Setup |
|
||
|
Chan N |
|||
|
Trigger Mode |
|||
|
SMU Trigger In |
|
||
|
SMU Trigger Out |
|
||
|
Source/Voltage Meter/Current Meter |
|
||
|
SMU Chan |
|||
|
Source type |
|||
|
Timeout |
|||
|
Dwell Before Sweep |
|||
|
Dwell After Point Set |
|||
|
Current Limit |
|||
|
Voltage Limit |
|||
|
Source Correction On |
|||
|
Offset |
|||
|
Scaling |
|||
|
Receiver Correction On |
|||
|
|
|||
|
|
|||
|
Source |
|||
|
Enable Output |
SYSTem:CONFigure:EDEVice:CHANnel<cnum>:BASE SYSTem:CONFigure:EDEVice:CHANnel<cnum>:COUNt SYSTem:CONFigure:EDEVice:CHANnel<cnum>:NAME SYSTem:CONFigure:EDEVice:CHANnel<cnum>:NUMBer |
||
|
Timeout |
|||
|
Dwell Per Point |
|||
|
Enable Modulation Control |
|||
| Trigger Mode | |||
| Trigger Port | |||
|
Edit Commands... |
|
||
|
Operation complete (*OPC) |
None |
||
|
Preset |
None |
||
|
Set CW Frequency |
None |
||
|
Set CW Sweep Mode |
None |
||
|
Set Power |
None |
||
|
Set Power State |
None |
||
|
Power Meter Setup... |
Interface |
||
|
Sensors |
|||
|
Tolerance |
|||
| Max Number of Readings | |||
|
Use Loss Table |
|||
|
Edit Table |
|||
|
External Testset... |
Select ID |
ControlLines |
|
|
Test Set |
ts.Add |
||
|
Enable Test Set Control |
None |
None |
|
|
Show Test Set Properties |
None |
None |
|
|
Port Control |
ts.SelectPort |
||
|
Control Lines |
ControlLines |
||
|
Line X |
None |
None |
|
|
DC Source |
COM Commands |
||
|
(E5092A only) |
None |
||