Installation Steps: 1 2 3 4 5 6 7
To generate signals using the N7601B Signal Studio for cdma2000/1xEV-DO software, you must have a properly configured PC and a properly configured instrument, as described in the following table.
N5172B EXG X-Series RF vector signal generator |
Firmware: Version B.01.10 or later (how to upgrade) Required options: N5172B-503 (9 kHz to 3 GHz frequency range) N5172B-653 (Internal baseband generator, 32 MSa/sec, up to 60 MHz RF bandwidth) N5172B-660 (upgrade baseband generator with real-time capability) Recommended options: N5172B-009 (internal Flash drive) N5172B-021 (upgrade baseband generator memory from 32 MSa to 256 MSa) N5172B-1EA (high power output for PA testing) N5172B-1ER (flexible reference input, 1-50 MHz) N5172B-403 (calibrated AWGN for testing with noise) N5172B-655 (upgrade baseband generator from 60 to 120 MHz RF bandwidth) N5172B-UNV (enhanced dynamic range) N5172B-UNZ (fast switching for manufacturing environments) |
N5182B MXG X-Series RF vector signal generator |
Firmware: Version B.01.10 or later (how to upgrade) Required options: N5182B-503 (9 kHz to 3 GHz frequency range) N5182B-656 (Internal baseband generator, 32 MSa/sec, up to 80 MHz RF bandwidth) N5182B-660 (upgrade baseband generator with real-time capability) Recommended options: N5182B-009 (internal Flash drive) N5182B-022 (upgrade baseband generator memory from 32 MSa to 512 MSa) N5182B-1EA (high power output for PA testing) N5182B-1ER (flexible reference input, 1-50 MHz) N5182B-1EQ (low power output for Rx testing) N5182B-403 (calibrated AWGN for testing with noise) N5182B-657 (upgrade baseband generator from 80 to 160 MHz RF bandwidth) N5182B-UNV (enhanced dynamic range) N5182B-UNZ (fast switching for manufacturing environments) |
M9381A PXIe vector signal generator |
Driver: Version 1.4.400.0 or later Recommended options: M9381A-M05 (memory 512 MSa) M9381A-M10 (memory 1024 MSa) M9381A-1EA (high output power) M9381A-B10 (RF modulation bandwidth 100 MHz) M9381A-B16 (RF modulation bandwidth 160 MHz) Additional options to consider: M9381A-F06 (frequency range 1 MHz to 6 GHz) Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
E6640A EXM wireless test set |
Software: Version E.16.06 or later Recommended options: E6640A-B85 (increases signal bandwidth to 80 MHz) E6640A-B1X (increases signal bandwidth to 160 MHz) Y-Options (these option models, beginning with "Y," combine signal creation and measurement applications) Additional options to consider: E6640A-506 (380 MHz to 6 GHz frequency range) E6640A-5WC (frequency range for wireless connectivity) |
- requires firmware version A.01.10 or later ( | |||
N5182A-503 |
250 kHz to 3 GHz frequency range |
||
Or the other frequency option: |
|||
N5182A-506 |
250 kHz to 6 GHz frequency range |
||
N5182A-651 |
Internal Baseband Generator (30 MSa/s and 8 MSa) |
||
Or
one of the |
|||
N5182A-652 |
Internal Baseband Generator (60 MSa/s and 8 MSa) |
||
N5182A-654 |
Internal Baseband Generator (125 MSa/s and 8 MSa) |
||
N5182A-UNV |
Enhanced Dynamic Range |
||
N5182A-019 |
Increased baseband generator memory to 64 MSa is also available, in addition to one of the Internal Baseband Generator options listed above. (Used to save several types of waveform files) |
||
N5182A-1EL |
Differential I/Q Outputs (Depends on the test requirements) |
||
N5182A-403 |
Calibrated AWGN Personality (used only for receiver test) |
- requires firmware version C.04.84 or later ( | |||
E4438C-503 |
250 kHz to 3 GHz frequency range |
||
Or the other frequency option: |
|||
E4438C-506 |
250 kHz to 6 GHz frequency range |
||
E4438C-6021 |
Internal Baseband Generator (64 MSa memory) |
||
E4438C-005 |
6 GB internal hard drive |
||
E4438C-UNJ |
Enhanced phase noise (required with E4438C-506) |
||
E4438C-403 |
Calibrated AWGN Personality (used only for receiver test) |
- requires firmware version C.04.85 or later ( | ||
E8267D-520 |
250 kHz to 20 GHz frequency range |
|
E8267D-6021 |
Internal Baseband Generator (64 MSa memory) |
|
E8267D-005 |
6 GB internal hard drive |
|
E8267D-UNX |
Ultra phase noise |
|
E8267D-005 |
6 GB internal hard drive |
|
E8267D-1EH |
Improved harmonics below 2 GHz |
|
E8267D-403 |
Calibrated AWGN Personality (used only for receiver test) |
|
|
N5106A-612 |
2 DSP blocks on 1 baseband card |
N5106A-632 |
2 I/O channels - 2 analog I/Q out and 2 digital I/O |
N5106A-EFP |
Baseband Generation |
N5106A-JFP |
Calibrated AWGN |
1. Recommended option: the baseband generator option can be any of the following: E4438C-001, -002, -601, -602 or E8267D-602
200 GB HDD with 2 GB free disk space at runtime (5 GB or higher recommended)
1024 x 768 screen resolution (1280 x 1024 recommended)
Windows 8.1 (Pro/Enterprise) (32/64 bit)1,2:
1 GHz or faster 32-bit or 64-bit processor
1 GB of memory minimum for the 32-bit version
2 GB of memory minimum for a 64-bit version
1.5 GB hard disk space (includes 1 GB for Microsoft .NET Framework and 65 MB for the Keysight IO Libraries)
Microsoft Internet Explorer (8.0 or later)
Microsoft .NET Framework 3.5 or .NET Framework 3.5 Service Pack 1 (included with Windows 7) (See "2. Downloading and Installing the .NET Framework")
Keysight IO Libraries, version 17.1 or later (See "3. Downloading and Installing the Keysight IO Libraries Suite")
Keysight License Manager (See "4. Downloading and Installing the Keysight License Manager ")
128 MB graphics memory with DirectX 9 graphics support (recommended)
Windows 7 (Professional/Ultimate/Enterprise)1,2:
1 GHz or faster 32-bit or 64-bit processor
1 GB of memory minimum for the 32-bit version
2 GB of memory minimum for a 64-bit version
1.5 GB hard disk space (includes 1 GB for Microsoft .NET Framework and 65 MB for the Keysight IO Libraries)
Microsoft Internet Explorer (8.0 or later)
Microsoft .NET Framework 3.5 or .NET Framework 3.5 Service Pack 1 (included with Windows 7) (See "2. Downloading and Installing the .NET Framework")
Keysight IO Libraries, version 17.1 or later (See "3. Downloading and Installing the Keysight IO Libraries Suite")
Keysight License Manager (See "4. Downloading and Installing the Keysight License Manager ")
128 MB graphics memory with DirectX 9 graphics support (recommended)
Installed GPIB IO interface card, LAN interface card, or USB/GPIB interface connector
Keysight VISA
Microsoft Windows Installer version 2.0 or later
Adobe Flash Player 7 or later (required for using the Signal Studio Configuration Assistant)
1 No support for Itanium64.
2 Signal Studio is compatible with the 64-bit operating system, but performs at the 32-bit speed.