Function |
Queries the open loop power control measurement result in the following order: Integrity Indicator, Pass/Fail, Open Loop Power Result, Detected UpPCH signature. |
Query |
Integrity Indicator: see Integrity Indicator. Pass/Fail
Initial UpPCH Tx Power Measurement Results
Detected UpPCH signature
|
Requirements |
Test Application Revision: A.03.00 and above |
Programming Example |
"FETCh:TOLPower?" |
Function |
Queries the pass/fail indication for the Initial UpPCH Tx Power Measurement Results. If the following condition is met, it fails: Initial UpPCH Tx Power (in dBm) – Expected Initial UpPCH Tx Power (in dBm) > Initial UpPCH Tx Power Limit(in dB), |
Query |
Range: 0 | 1, 9.91 E+37 |
Requirements |
Test Application Revision: A.03.00 and above |
Programming Example |
"FETCh:TOLPower:FAIL?" |
Function |
Queries the measurement integrity indicator for the last open loop power control measurement completed. Zero indicates a normal measurement. |
Query |
Range: 0 to 32 |
Requirements |
Test Application Revision: A.03.00 and above |
Programming Example |
"FETCh:TOLPower:INTegrity?" |
Function |
Queries the initial UpPCH Tx power result. |
Query |
Range: Measured Value in dBm, 9.91 E+37 Resolution: 0.01 |
Requirements |
Test Application Revision: A.03.00 and above |
Programming Example |
"FETCh:TOLPower:POWer?" |
Function |
Queries the Detected UpPCH signature in the open loop power control measurement. |
Query |
Range: 0 to 255, 9.91 E+37 Resolution: 1 |
Requirements |
Test Application Revision: A.03.00 and above |
Programming Example |
"FETCh:TOLPower:POWer?" |