These commands allow you to start and stop measurements.
For more information on the GPIB Command conventions, see GPIB Command conventions
Function |
These commands initiate (start) the specified measurements:
|
Setting |
No setting |
Query |
No query: |
*RST Setting |
None |
Requirements |
Test Application Revision: A.01.00 and above Test Application Revision: A.03.00 and above, added TOLP, TBLerror and THBLerror. Test Application Revision: A.04.00 and above, added TOOSynch, TFDT, THCQuality. Test Application Revision: A.08.00 and above, added DEHich and DEAGch. |
Programming Example |
"INITiate:TCPower" |
Function |
Deactivates the selected measurement. See INITiate:<measurement mnemonic>[:ON] for a list of measurements. |
Setting |
No setting |
Query |
No query: |
*RST Setting |
None |
Requirements |
Test Application Revision: A.01.00 and above Test Application Revision: A.03.00 and above, added TOLP, TBLerror and THBLerror. Test Application Revision: A.04.00 and above, added TOOSynch, TFDT, THCQuality. Test Application Revision: A.07.00 and above, added DEHich and DEAGch. |
Programming Example |
"INITiate:TCPower:OFF" |
Function |
Queries (one at a time) which measurements, if any, are finished or have timed-out. |
Setting |
No setting |
Query |
|
*RST Setting |
None |
Requirements |
Test Application Revision: A.01.00 and above Test Application Revision: A.03.00 and above, added TOLP, TBLerror and THBLerror. Test Application Revision: A.04.00 and above, added TOOSynch, TFDT, THCQuality. Test Application Revision: A.08.00 and above, added DEHich and DEAGch. |
Programming Example |
"INITIATE:DONE?" |
Function |
Specifies if a measurement done flag is considered (using the INCLude or EXCLude settings) when the INITiate:DONE? query is sent. See INITiate<:measurement mnemonic>[:ON] for a list of measurement mnemonics. |
Setting |
INCLude | EXCLude |
Query |
INCL|EXCL |
*RST Setting |
None |
Requirements |
Test Application Revision: A.01.00 and above Test Application Revision: A.02.00 and above, added TOB, TDP, TOOP and TBERror. Test Application Revision: A.03.00 and above, added TOLP, TBLerror and THBLerror. Test Application Revision: A.04.00 and above, added TOOSynch, TFDT, THCQuality. Test Application Revision: A.08.00 and above, added DEHich and DEAGch. |
Programming Example |
"INITIATE:DONE:FLAG:TCP EXCLUDE" |
Function |
Queries the measurements that are on. Returns a comma separated list of measurement mnemonics. |
Setting |
No setting |
Query |
|
*RST Setting |
None |
Requirements |
Test Application Revision: A.01.00 and above Test Application Revision: A.03.00 and above, added TOLP, TBLerror and THBLerror. Test Application Revision: A.04.00 and above, added TOOSynch, TFDT, THCQuality. Test Application Revision: A.08.00 and above, added DEHich and DEAGch. |
Programming Example |
"INITiate:ON?" |
Function |
Queries the arm state of the fast device tune measurement.
|
Query |
Range: 0 | 1 |
Requirements |
Test Application Revision: A.04.00 and above |
Programming Example |
"INITiate:TFDTune:ARMed?" |