CALL:CCPChannel:PRIMary[:SLEVel]

Function

Sets/queries the initial power offset of the primary common control physical channel. This command sets the power offset level and turns on the power offset.

This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.

Setting

Range: -20.00 dB to 0 dB

Resolution: 0.01

Query

Range: -20.00 dB to 0 dB

Resolution: 0.01

*RST Setting

-5.3 dB
Requirements

Test Application Revision: A.02 and above.

Lab Application Revision: A.01 and above

Test Application Revision A.06 changed *RST Setting to -5.3 dB.

Lab Application Revision C.01 changed *RST Setting to -5.3 dB.

Programming Example

 
OUTPUT 714;"CALL:CCPCHANNEL:PRIMARY:SLEVEL -15DB" !Enables and sets the initial P-CCPCH power offset to -15 dB.

CALL:CCPChannel:PRIMary:LEVel

Function

Sets/queries the primary common control physical channel's initial power offset.

This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.

Setting

Range: -20.00 dB to 0 dB

Resolution: 0.01

Query

Range: -20.00 dB to 0 dB

Resolution: 0.01

*RST Setting

-5.3 dB
Requirements

Test Application Revision: A.02 and above.

Lab Application Revision: A.01 and above.

Test Application Revision A.06 changed *RST Setting to -5.3 dB.

Lab Application Revision C.01 changed *RST Setting to -5.3 dB.

Programming Example

 
OUTPUT 714;"CALL:CCPCHANNEL:PRIMARY:LEVEL -15DB" !Sets the initial P-CCPCH power offset to -15 dB.

CALL:CCPChannel:PRIMary:STATe

Function

Sets/queries the primary common control physical channel's state.

This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

1 (on)
Requirements

Test Application Revision: A.02 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:CCPCHANNEL:PRIMARY:STATE ON" 

CALL:CCPChannel:SECondary[:SLEVel]

Function

Sets/queries the initial power offset of the secondary common control physical channel. This command sets the power offset level and turns on the power offset.

This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.

Setting

Range: -20.00 dB to 0 dB

Resolution: 0.01

Query

Same as setting.

*RST Setting

-10.3 dB
Requirements

Test Application Revision: A.02 and above.

Lab Application Revision: A.01 and above.

Test Application Revision A.06 changed *RST Setting to -10.3 dB.

Lab Application Revision C.01 changed *RST Setting to -10.3 dB.

Programming Example

 
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:SLEVEL -10DB" !Sets P-CCPCH initial power offset to -10 dB.

CALL:CCPChannel:SECondary:CCODe

Function

THIS COMMAND IS OBSOLETE. Please use CALL:CCPChannel:SECondary:CCODe:CODE .

Sets/queries the secondary common control physical channel's channelization code.

Setting

Range: CODE6|CODE7|CODE9|CODE16|CODE17|CODE26|CODE57

Query

Range: CODE6|CODE7|CODE9|CODE16|CODE17|CODE26|CODE57

*RST Setting

CODE7
Requirements

Test Application Revision: A.02 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:CCODE CODE6"
! Sets the S-CCPCH channelization code to 6.

CALL:CCPChannel:SECondary:CCODe:CODE

Function

Sets/queries the secondary common control physical channel's channelization code. Code 0 is reserved for the CPICH.

This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected While in Active Cell Mode." Use the cell off operating mode when changing this value.

Setting

Range: 1 to 63

Resolution: 1

Query

Range: 1 to 63

Resolution: 1

*RST Setting

7

Requirements

Lab Application Revision: F.00 and above

Test Application Revision: A.14 and above

Programming Example

 
OUTPUT 714;"CALL:CCPChannel:SECondary:CCODe:CODE 7"

CALL:CCPChannel:SECondary:CONFigure

Function

Sets/queries SCCPCH/PRACH Configuration .

Setting

Range: SIGNaling|STRaffic

Query

Range: SIGN|STR

*RST Setting

SIGNaling
Requirements

Lab Application Revision: F.00 and above

Programming Example

 
OUTPUT 714;"CALL:CCPChannel:SECondary:CONFigure SIGNaling"
! Sets the SCCPCH/PRACH Configuration to Signaling only.

CALL:CCPChannel:SECondary:CONNected:CONFig:STATe

Function

Sets/queries the Connected S-CCPH Channel Configuration State.

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

1 (on)
Requirements

Lab Application Revision: F.00 and above

Test Application Revision: A.14 and above

Programming Example

 
OUTPUT 714;"CALL:CCPChannel:SECondary:CONNected:CONFig:STATe" !Enables the Connected S-CCPH Channel Configuration. 

CALL:CCPChannel:SECondary:LEVel

Function

Sets/queries the secondary common control physical channel's initial power offset.

This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.

Setting

Range: -20.00 dB to 0 dB

Resolution: 0.01

Query

Range: -20.00 dB to 0 dB

Resolution: 0.01

*RST Setting

-10.3 dB
Requirements

Test Application Revision: A.02 and above.

Lab Application Revision: A.01 and above.

Test Application Revision A.06 changed *RST Setting to -10.3 dB.

Lab Application Revision C.01 changed *RST Setting to -10.3 dB.

Programming Example

 
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:LEVEL -5" !Sets the intial common control physical channel level to -5 dB.

CALL:CCPChannel:SECondary:STATe

Function

Sets/queries the secondary common control physical channel's state.

This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this setting.

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

1 (on)
Requirements

Test Application Revision: A.02 and above.

Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:CCPCHANNEL:SECONDARY:STATE ON" !Enables the secondary common control physical channel.