Sets/queries the page indicator channel's initial power offset, and turns its state to ON.
This setting cannot be changed while in active cell operating mode (when available). Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
Setting
Range: - 20 to 0 dB
Resolution: 0.01
Query
Range: -20 to 0 dB
Resolution: 0.01
*RST Setting
-8.3 dB
Requirements
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
Test Application Revision A.06 changed *RST Setting to -8.3 dB.
Lab Application Revision C.01 changed *RST Setting to -8.3 dB.
Sets/queries the page indicator channel's channelization code.
Setting
Range: CODE14|CODE15|CODE16|CODE17
Query
Range: CODE14|CODE15|CODE16|CODE17
*RST Setting
CODE16
Requirements
Test Application Revision: A.01 and above
Lab Application Revision: A.01 and above
Programming Example
OUTPUT 714;"CALL:PICHannel:CCODe CODE17"
CALL[:CELL]:PICHannel:CCODe:CODE
Function
Sets/queries the page indicator channel's channelization code.
This setting cannot be changed while in active cell operating mode (when available). Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
Setting
Range: 2 to 255
Query
Range: 2 to 255
*RST Setting
16
Requirements
Lab Application Revision: F.00 and above
Test Application Revision: A.14 and above
Programming Example
OUTPUT 714;"CALL:PICHannel:CCODe:CODE 16"
CALL[:CELL]:PICHannel:LEVel
Function
Sets/queries the page indicator channel's initial power offset.
This setting cannot be changed while in active cell operating mode (when available). Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.
Setting
Range: - 20 to 0 dB
Resolution: 0.01
Query
Range: -20 to 0 dB
Resolution: 0.01
*RST Setting
-8.3 dB
Requirements
Test Application Revision: A.02 and above.
Lab Application Revision: A.01 and above.
Test Application Revision A.06 changed *RST Setting to -8.3 dB.
Lab Application Revision C.01 changed *RST Setting to -8.3 dB.
Programming Example
OUTPUT 714;"CALL:PICHANNEL:LEVEL -10DB"
CALL[:CELL]:PICHannel:STATe
Function
Sets/queries the state of the page indicator channel's initial power offset.
This setting cannot be changed while in active cell operating mode. Attempting to change this setting while in this mode results in the following error message: "Command Rejected. Change Not Allowed in Active Cell Mode." Use the cell off operating mode when changing this value.