FETCh:WOOPower

FETCh:WOOPower

Last updated: January 16, 2009

GPIB Command Conventions

FETCh:WOOPower[:ALL]?

Function

Queries the PRACH transmit on/off power measurement results. See PRACH Transmit On/Off Power Measurement Results .

[:ALL] returns measurement results in the following order: Integrity, Pre Burst Off Power level, Pre Burst Off Power pass/fail, Burst On Power, Open Loop Power Error value, Open Loop Power Error pass/fail, Post Burst Off Power level, Post Burst Off Power pass/fail.

Instead of returning [:ALL] results, you may query the result for any particular measurement result individually using the appropriate keywords (for example, FETCh:WOOPower:OFF:PRE[:BURSt]?).

Requirements

Test Application Revision: A.03 and above.

Lab Application Revision: A.01 and above.

Query

Integrity: see Integrity Indicator

Pre Burst Off Power level

  • Range: -99.99 to 00.00 dBm, 9.91 E+37

  • Resolution: 0.01 dBm

Pre Burst Off Power pass/fail

  • Range: 0 (pass), 1 (fail), 9.91 E+37

Burst On Power

  • Range: -99.99 to 99.99 dBm, 9.91 E+37

  • Resolution: 0.01 dBm

Open Loop Power Error value

  • Range: -99.99 to +99.99 dB, 9.91E+37
  • Resolution: 0.01 dB

Open Loop Power Error pass/fail

  • Range: 0 (pass), 1 (fail), 9.91 E+37

Post Burst Off Power level

  • Range: -99.99 to 00.00 dBm, 9.91 E+37

  • Resolution: 0.01 dBm

Post Burst Off Power pass/fail

  • Range: 0 (pass), 1 (fail), 9.91 E+37

Programming Example

 
OUTPUT 714;"FETCh:WOOPower?" 
! returns Integrity, Pre Burst Off Power level, Pre Burst Off Power pass/fail,
! Burst On Power, Open Loop Power Error value, Open Loop Power Error pass/fail,
! Post Burst Off Power level, Post Burst Off Power pass/fail
 
OUTPUT 714;"FETCh:WOOPower:INTegrity?" 
! returns Integrity
 
OUTPUT 714;"FETCh:WOOPower:OFF:PRE?" 
! returns Pre Burst Off Power level