Last updated: January 16, 2009
This section is only applicable to the lab application.
| 
 Sets/queries the Number filtered ACK/NACK responses to test .  | 
|
| 2000 | |
OUTPUT 714;"SETup:HRCQuality:SENSe:ANResponses:FILTered 2000" !Sets the Number of filtered ACK/NACK responses to test to 2000.  | 
|
| 
 Sets/queries the Filtered BLER for initial CQI sense decision .  | 
|
| 10.00 (%) | |
OUTPUT 714;"SETup:HRCQuality:SENSe:BLERatio:FILTered:BASE:DECision 10" !Sets the Filtered BLER for initial CQI sense decision to 10 %.  | 
|
| 
 Sets/queries the Filtered BLER for PASS/FAIL: Median_CQI-1 .  | 
|
| 10.00 | |
OUTPUT 714;"SETup:HRCQuality:SENSe:BLERatio:FILTered:CQIMinus1 10" !Sets the Filtered BLER for PASS/FAIL: Median_CQI-1 to 10%.  | 
|
| 
 Sets/queries the Filtered BLER for PASS/FAIL: Median_CQI+2 .  | 
|
| 10.00 | |
OUTPUT 714;"SETup:HRCQuality:SENSe:BLERatio:FILTered:CQIPlus2 10" !Sets the Filtered BLER for PASS/FAIL: Median_CQI+2 to 10%.  | 
|
| 
 The setting form of this command performs two functions: (1) sets the measurement's timeout value (see Measurement Timeouts ), and (2) sets the measurement's timeout state to 1 (on). The query form returns the measurement's timeout value. See HSDPA Reporting of Channel Quality Indicator Measurement Description .  | 
|
| Same as setting. | |
OUTPUT 714;"SETup:HRCQuality:TIMeout 20" ! Sets measurement's timeout state to ON and sets the timeout time to 20 seconds.  | 
|
| 
 Sets/queries the measurement's timeout state (see Measurement Timeouts ). See HSDPA Reporting of Channel Quality Indicator Measurement Description .  | 
|
| Range: 1|0 | |
| 0 (off) | |
OUTPUT 714;"SETup:HRCQuality:TIMeout:STATe 0" ! Sets measurement's timeout state to OFF.  | 
|
| 
 Sets/queries the measurement's timeout setting to be used when the timeout state is set to ON (see Measurement Timeouts ). See HSDPA Reporting of Channel Quality Indicator Measurement Description  | 
|
| Same as setting | |
| 20 seconds | |
OUTPUT 714;"SETup:HRCQuality:TIMeout:TIME 20" !Sets the measurement's timeout to 20 seconds.  | 
|
| 
 Sets/queries the Number of CQI Reports to test .  | 
|
| 2000 | |
OUTPUT 714;"SETup:HRCQuality:VARiance:CQIReports 2000" !Sets the Number of CQI Reports to test to 2000.  | 
|
| 
 Sets/queries the Starting Downlink TF CQI .  | 
|
| Same as setting | |
| 16 | |
OUTPUT 714;"SETup:HRCQuality:VARiance:CQIValue:INITial 16" !Sets the Starting Downlink TF CQI to 16.  | 
|
| 
 Sets/queries the Percentage of CQI values within range .  | 
|
| 90.00 % | |
OUTPUT 714;"SETup:HRCQuality:VARiance:CQIValues:WRANge 90" !Sets the Percentage of CQI values within range to 90%.  | 
|