SETup:HRCQuality

SETup:HRCQuality

Last updated: January 16, 2009

GPIB Command Conventions

This section is only applicable to the lab application.

SETup:HRCQuality:SENSe:ANResponses:FILTered[:COUNt]

Function

Sets/queries the Number filtered ACK/NACK responses to test .

Setting

Range: 1 to 99000

Query

Range: 1 to 99000

*RST Setting

2000

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:SENSe:ANResponses:FILTered 2000" 
!Sets the Number of filtered ACK/NACK responses to test to 2000.

SETup:HRCQuality:SENSe:BLERatio:FILTered:BASE:DECision

Function

Sets/queries the Filtered BLER for initial CQI sense decision .

Setting

Range: 0.00 to 100.00

Query

Range: 0.00 to 100.00

*RST Setting

10.00 (%)

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:SENSe:BLERatio:FILTered:BASE:DECision 10" 
!Sets the Filtered BLER for initial CQI sense decision to 10 %.

SETup:HRCQuality:SENSe:BLERatio:FILTered:CQIMinus1[:LIMit]

Function

Sets/queries the Filtered BLER for PASS/FAIL: Median_CQI-1 .

Setting

Range: 0.00 to 100.00

Query

Range: 0.00 to 100.00

*RST Setting

10.00

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:SENSe:BLERatio:FILTered:CQIMinus1 10" 
!Sets the Filtered BLER for PASS/FAIL: Median_CQI-1 to 10%.

SETup:HRCQuality:SENSe:BLERatio:FILTered:CQIPlus2[:LIMit]

Function

Sets/queries the Filtered BLER for PASS/FAIL: Median_CQI+2 .

Setting

Range: 0.00 to 100.00

Query

Range: 0.00 to 100.00

*RST Setting

10.00

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:SENSe:BLERatio:FILTered:CQIPlus2 10" 
!Sets the Filtered BLER for PASS/FAIL: Median_CQI+2 to 10%.

SETup:HRCQuality:TIMeout[:STIMe]

Function

The setting form of this command performs two functions: (1) sets the measurement's timeout value (see Measurement Timeouts ), and (2) sets the measurement's timeout state to 1 (on).

The query form returns the measurement's timeout value.

See HSDPA Reporting of Channel Quality Indicator Measurement Description .

Setting

Range: 0.1 to 999.9 seconds

Resolution: 0.1 second

Query

Same as setting.

*RST Setting

Timeout value: 20 seconds

Timeout state: off

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:TIMeout 20" 
! Sets measurement's timeout state to ON and sets the timeout time to 20 seconds.

SETup:HRCQuality:TIMeout:STATe

Function

Sets/queries the measurement's timeout state (see Measurement Timeouts ).

See HSDPA Reporting of Channel Quality Indicator Measurement Description .

Setting

Range: 1|ON|0|OFF

Query

Range: 1|0

*RST Setting

0 (off)

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:TIMeout:STATe 0" 
! Sets measurement's timeout state to OFF.

SETup:HRCQuality:TIMeout:TIME

Function

Sets/queries the measurement's timeout setting to be used when the timeout state is set to ON (see Measurement Timeouts ).

See HSDPA Reporting of Channel Quality Indicator Measurement Description

Setting

Range: 0.1 to 999.9 seconds

Resolution: 0.1 second

Query

Same as setting

*RST Setting

20 seconds

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:TIMeout:TIME 20" 
!Sets the measurement's timeout to 20 seconds.

SETup:HRCQuality:VARiance:CQIReports[:COUNt]

Function

Sets/queries the Number of CQI Reports to test .

Setting

Range: 1 to 99000

Query

Range: 1 to 99000

*RST Setting

2000

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:VARiance:CQIReports 2000" 
!Sets the Number of CQI Reports to test to 2000.

SETup:HRCQuality:VARiance:CQIValue:INITial

Function

Sets/queries the Starting Downlink TF CQI .

Setting

Range: 1 to 30

Query

Same as setting

*RST Setting

16

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:VARiance:CQIValue:INITial 16" 
!Sets the Starting Downlink TF CQI to 16.

SETup:HRCQuality:VARiance:CQIValues:WRANge

Function

Sets/queries the Percentage of CQI values within range .

Setting

Range: 0.00 to 100.00

Query

Range: 0.00 to 100.00

*RST Setting

90.00 %

Requirements

Lab Application Revision: E.00.16 and above

Programming Example

 
OUTPUT 714;"SETup:HRCQuality:VARiance:CQIValues:WRANge 90" 
!Sets the Percentage of CQI values within range to 90%.