CALL:SHANdoff

CALL:SHANdoff

Last updated: January 16, 2009

This section is only applicable to the lab application.

GPIB Command Conventions

CALL:SHANdoff:ENABle

Function

Turns Soft Handover On or Off. (See Enabling Soft Handover )

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

OFF

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:ENABle ON" 
!Turns Soft Handover ON.

CALL:SHANdoff:EVENt:ENABle

Function

Turns Event State On or Off (enables/disables event reporting). (See Event Reporting )

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

OFF

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EVENt:ENABle ON" 
!Turns Event State ON.

CALL:SHANdoff:EVENt:SEND:CONFig

Function

Sends a Measurement Control message. You must send this command after configuring an event parameter (CALL:SHANdoff:EVent1A - 1F commands) for the new event parameter value to be implemented by the UE. (See Event Reporting ).

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EVENt:SEND:CONFig" 
!Sends a Measurement Control message.

CALL:SHANdoff:EVent1A:STATe

Function

Controls the UTRA FDD Event 1a ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting.

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

ON

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1A:STATe ON" 
!Turns the Event 1a State ON.

CALL:SHANdoff:EVent1A:REPorting:RANGe

Function

Controls the UTRA FDD Event 1a Reporting Range Constant. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 to 14.5 dB

Resolution: 0.5 dB

Query

Same as setting

*RST Setting

0.0 dB
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 14.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1A:REPorting:RANGe 3" 
!Sets the UTRA FDD Event 1a Reporting Range Constant to 3 dB.

CALL:SHANdoff:EVent1A:HYSTeresis

Function

Controls the UTRA FDD Event 1a Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 dB to 7.5 dB

Resolution: 0.5 dB

Query

Same as setting

*RST Setting

1.5 dB
Requirements Lab Application Revision: C.01 and above, new range 0 to 7.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1A:HYSTeresis 4" 
!Sets the UTRA FDD Event 1a Hysteresis to 4 dB.

CALL:SHANdoff:EVent1A:WVALue

Function

Controls the UTRA FDD Event 1a "W" Value. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 to 2.0

Resolution: 0.1

Query

Same as setting

*RST Setting

0.0
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 2.0

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1A:WVALue 0.5" 
!Sets the UTRA FDD Event 1a "W" Value to 0.5.

CALL:SHANdoff:EVent1B:STATe

Function

Controls the UTRA FDD Event 1b ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting.

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

ON

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1B:STATe ON" 
!Turns the Event 1b State ON.

CALL:SHANdoff:EVent1B:REPorting:RANGe

Function

Controls the UTRA FDD Event 1b Reporting Range Constant. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 to 14.5 dB

Resolution: 0.5 dB

Query

Same as setting

*RST Setting

0.0 dB
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 14.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1B:REPorting:RANGe 3" 
!Sets the UTRA FDD Event 1b Reporting Range Constant to 3 dB.

CALL:SHANdoff:EVent1B:HYSTeresis

Function

Controls the UTRA FDD Event 1b Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 dB to 7.5 dB

Resolution: 0.5 dB

Query

Same as setting

*RST Setting

1.5 dB
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1B:HYSTeresis 4" 
!Sets the UTRA FDD Event 1b Hysteresis to 4.0 dB.

CALL:SHANdoff:EVent1B:WVALue

Function

Controls the UTRA FDD Event 1b "W" Value. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 to 2.0

Resolution: 0.1

Query

Same as setting
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 2.0

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1B:WVALue 5" 
!Sets the UTRA FDD Event 1b "W" Value to 0.5 dB.

CALL:SHANdoff:EVent1C:STATe

Function

Controls the UTRA FDD Event 1c ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting.

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

ON

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1C:STATe ON" 
!Turns the Event 1c State ON.

CALL:SHANdoff:EVent1C:HYSTeresis

Function

Controls the UTRA FDD Event 1c Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 dB to 7.5 dB

Resolution: 0.5 dB

Query

Same as setting

*RST Setting

1.5 dB
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1C:HYSTeresis 4" 
!Sets the UTRA FDD Event 1c Hysteresis to 4.0 dB.

CALL:SHANdoff:EVent1D:STATe

Function

Controls the UTRA FDD Event 1d ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting.

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

ON

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1D:STATe ON" 
!Turns the Event 1d State ON.

CALL:SHANdoff:EVent1D:HYSTeresis

Function

Controls the UTRA FDD Event 1c Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 dB to 7.5 dB

Resolution: 0.5 dB

Query

Same as setting

*RST Setting

1.5 dB
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1D:HYSTeresis 4" 
!Sets the UTRA FDD Event 1d Hysteresis to 4.0 dB.

CALL:SHANdoff:EVent1E:STATe

Function

Controls the UTRA FDD Event 1e ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting.

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

ON

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1E:STATe ON" 
!Turns the Event 1e State ON.

CALL:SHANdoff:EVent1E:HYSTeresis

Function

Controls the UTRA FDD Event 1e Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 dB to 7.5 dB

Resolution: 0.5 dB

Query

Same as setting

*RST Setting

1.5 dB
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1E:HYSTeresis 4" 
!Sets the UTRA FDD Event 1e Hysteresis to 4.0 dB.

CALL:SHANdoff:EVent1E:THREshold

Function

Controls the UTRA FDD Event 1e Threshold. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: -115 to -25 dBm

Resolution: 1

Query

Same as setting

*RST Setting

-60 dBm
Requirements Lab Application Revision: C.01 and above, new range -115 to -25 dBm

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1E:THREshold -70" 
!Sets the UTRA FDD Event 1e Threshold to -70 dBm.

CALL:SHANdoff:EVent1F:STATe

Function

Controls the UTRA FDD Event 1f ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting.

Setting

Range: 0|OFF|1|ON

Query

Range: 0|1

*RST Setting

ON

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1F:STATe ON" 
!Turns the Event 1f State ON.

CALL:SHANdoff:EVent1F:HYSTeresis

Function

Controls the UTRA FDD Event 1f Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: 0.0 dB to 7.5 dB

Resolution: 0.5

Query

Same as setting

*RST Setting

1.5 dB
Requirements Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1F:HYSTeresis 4" 
!Sets the UTRA FDD Event 1f Hysteresis to 4.0 dB.

CALL:SHANdoff:EVent1F:THREshold

Function

Controls the UTRA FDD Event 1f Threshold. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ).

Setting

Range: -115 to -25 dBm

Resolution: 1

Query

Same as setting

*RST Setting

-80 dBm
Requirements Lab Application Revision: C.01 and above, new range -115 to -25 dBm

Programming Example

 
OUTPUT 714;"CALL:SHANdoff:EV1F:THREshold -70" 