Last updated: January 16, 2009
This section is only applicable to the lab application.
Turns Soft Handover On or Off. (See Enabling Soft Handover ) |
|
OFF | |
OUTPUT 714;"CALL:SHANdoff:ENABle ON" !Turns Soft Handover ON. |
Turns Event State On or Off (enables/disables event reporting). (See Event Reporting ) |
|
OFF | |
OUTPUT 714;"CALL:SHANdoff:EVENt:ENABle ON" !Turns Event State ON. |
Sends a Measurement Control message. You must send this command after configuring an event parameter (CALL:SHANdoff:EVent1A - 1F commands) for the new event parameter value to be implemented by the UE. (See Event Reporting ). |
|
OUTPUT 714;"CALL:SHANdoff:EVENt:SEND:CONFig" !Sends a Measurement Control message. |
Controls the UTRA FDD Event 1a ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting. |
|
ON | |
OUTPUT 714;"CALL:SHANdoff:EV1A:STATe ON" !Turns the Event 1a State ON. |
Controls the UTRA FDD Event 1a Reporting Range Constant. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
0.0 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 14.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1A:REPorting:RANGe 3" !Sets the UTRA FDD Event 1a Reporting Range Constant to 3 dB. |
Controls the UTRA FDD Event 1a Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
1.5 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0 to 7.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1A:HYSTeresis 4" !Sets the UTRA FDD Event 1a Hysteresis to 4 dB. |
Controls the UTRA FDD Event 1a "W" Value. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
0.0 | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 2.0 |
OUTPUT 714;"CALL:SHANdoff:EV1A:WVALue 0.5" !Sets the UTRA FDD Event 1a "W" Value to 0.5. |
Controls the UTRA FDD Event 1b ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting. |
|
ON | |
OUTPUT 714;"CALL:SHANdoff:EV1B:STATe ON" !Turns the Event 1b State ON. |
Controls the UTRA FDD Event 1b Reporting Range Constant. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
0.0 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 14.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1B:REPorting:RANGe 3" !Sets the UTRA FDD Event 1b Reporting Range Constant to 3 dB. |
Controls the UTRA FDD Event 1b Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
1.5 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1B:HYSTeresis 4" !Sets the UTRA FDD Event 1b Hysteresis to 4.0 dB. |
Controls the UTRA FDD Event 1b "W" Value. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 2.0 |
OUTPUT 714;"CALL:SHANdoff:EV1B:WVALue 5" !Sets the UTRA FDD Event 1b "W" Value to 0.5 dB. |
Controls the UTRA FDD Event 1c ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting. |
|
ON | |
OUTPUT 714;"CALL:SHANdoff:EV1C:STATe ON" !Turns the Event 1c State ON. |
Controls the UTRA FDD Event 1c Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
1.5 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1C:HYSTeresis 4" !Sets the UTRA FDD Event 1c Hysteresis to 4.0 dB. |
Controls the UTRA FDD Event 1d ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting. |
|
ON | |
OUTPUT 714;"CALL:SHANdoff:EV1D:STATe ON" !Turns the Event 1d State ON. |
Controls the UTRA FDD Event 1c Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
1.5 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1D:HYSTeresis 4" !Sets the UTRA FDD Event 1d Hysteresis to 4.0 dB. |
Controls the UTRA FDD Event 1e ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting. |
|
ON | |
OUTPUT 714;"CALL:SHANdoff:EV1E:STATe ON" !Turns the Event 1e State ON. |
Controls the UTRA FDD Event 1e Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
1.5 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1E:HYSTeresis 4" !Sets the UTRA FDD Event 1e Hysteresis to 4.0 dB. |
Controls the UTRA FDD Event 1e Threshold. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
-60 dBm | |
Requirements | Lab Application Revision: C.01 and above, new range -115 to -25 dBm |
OUTPUT 714;"CALL:SHANdoff:EV1E:THREshold -70" !Sets the UTRA FDD Event 1e Threshold to -70 dBm. |
Controls the UTRA FDD Event 1f ON/OFF State. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). It is recommended that you set CALL:SHANdoff:EVENt:ENABle to OFF before changing this setting. You must then turn CALL:SHANdoff:EVENt:ENABle back ON to enable event reporting. |
|
ON | |
OUTPUT 714;"CALL:SHANdoff:EV1F:STATe ON" !Turns the Event 1f State ON. |
Controls the UTRA FDD Event 1f Hysteresis. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
1.5 dB | |
Requirements | Lab Application Revision: C.01 and above, new range 0.0 to 7.5 dB |
OUTPUT 714;"CALL:SHANdoff:EV1F:HYSTeresis 4" !Sets the UTRA FDD Event 1f Hysteresis to 4.0 dB. |
Controls the UTRA FDD Event 1f Threshold. In order for changes to this event parameter to be seen by the UE, you must send the CALL:SHANdoff:EVENt:SEND:CONFig command. (See Event Reporting ). |
|
Same as setting | |
-80 dBm | |
Requirements | Lab Application Revision: C.01 and above, new range -115 to -25 dBm |
OUTPUT 714;"CALL:SHANdoff:EV1F:THREshold -70" !Sets the UTRA FDD Event 1f Threshold to -70 dBm. |