Measurement Interval (1xEV-DO)
1xEV-DO Standard Setups/Presets Table.)
1 slot (Seespecifies the time length of Result Length data that is used for computing and displaying the trace data results. Measurement Interval can be specified in increments of half (0.5) slots. One slot is equal to 2048 chips or 1.667 ms long at the default chip rate.
Measurement Interval does not affect composite trace data results or CDE trace data results
Measurement Interval and Measurement Offset parameters are used to specify what segment of the Result Length data is used for data analysis, see About Measurement Interval and Offset.
See Also
About Measurement Interval and Offset