Walsh Code Number - Despread Channel (1xEV-DO)

Default: 0 (See 1xEV-DO Standard Setups/Presets Table.) 

Range: 0 to (Walsh Code Length -1)

The Despread Channel Walsh Code Number is used to specify the code channel for the channel trace data measurement results (Chan Error Vector, Chan IQ Meas Time, Chan IQ Ref Time, Chan Mag Error, Chan Phase Error and Chan Syms/Errs trace data).

Long Code Mask Q is only available when the Reverse link direction is selected (MeasSetup > 1xEV-DO Demod Properties > Format tab > Direction > ReverseLink) .

See Also

Channel/Layer Tab (1xEV-DO Demod Properties)

1xEV-DO Demod Properties