Controls the marker settings used in the SA application.
These commands are Superseded by the CALCulate:MEASure:SA commands.
CALCulate:SA:MARKer: BDENsity | ACPR | [:STATe] | BW | DATA? | EQSPan | NOISe | [:STATe] | NPR | [:STATe] | POWer | BW | [:STATe] | TONE | BW | [:STATe] | TSPacing BPOWer | DATA? | SPAN | [:STATe] OCCBand | CENTer? | PERCent | POWer? | SPAN? | [:STATe]
|
Click on a keyword to view the command details.
See Also
Critical
Note: CALCulate commands act on the selected measurement. You can
select one measurement for each channel using Calc:Par:MNUM
or Calc:Par:Select. Learn
more.
If
you use Calc:Par:Cat? to return the list
of current measurements, the returned string will be similar to ‘CH1_B_1,B’.
To
select this measurement as a parameter for SA, you need to send Calc:Par:Sel
‘CH1_B_1’.
Moreover,
most of the following commands will return ‘+202, “Parameter not valid”
if they are called with marker number n, and marker number n is not currently
turned ON.
Important: Learn about programming the reference marker.
Note: For all band
power marker family (this includes BNOise, BPOWer, OCCBand markers) and
when measuring wideband repetitive modulated signals, there is basically
2 approaches to get good measurements:
- Either run
the coherent mode of SA if the modulated test signal repetition period
or tone spacing is known and a frequency reference connection is made
between the signal source and the PNA (usually the 10 MHz ref signal BNC).
See SA Setup Coherence.
- Or
make use of a RBW that is equal or smaller than 1/20 of the modulated
test signal tone spacing (rule of thumb). The test signal tone spacing
is 1/ the test signal duration. For example, if the ARB file that generates
the test signal replays each 100 microseconds, it means the tone spacing
is 10 kHz. So, we recommend to set the RBW to 500 Hz or below.
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) or N524xB models with Option S93070xB (Read-Write) Sets and reads the ACPR density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<bool> |
Choose from: 0 - OFF - Turn band density marker OFF. 1 - ON - Turn band density marker ON. |
Examples |
'Select the measurement CALC2:PAR:SEL "M2SA_CH2_A" 'Create marker3 on that measurement CALC2:MARK3 ON 'Make it a band density noise marker CALC2:SA:MARK3:BDEN:ACPR:STAT 1 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:ACPR[:STATe]? |
Return Type |
Boolean |
0 |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the bandwidth of the band density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<num> |
Choose a bandwidth. |
Examples |
CALC:SA:MARK:BDEN:BW 1e6 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:BW? |
Return Type |
Numeric |
1 MHz |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-only) Returns the band density level in dBm/Hz from the band density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that SA channel. If unspecified, <ch> is set to 1. |
<n> |
Band density marker number. If unspecified, <n> is set to 1. |
Examples |
CALC:SA:MARK:BDEN:DATA? calculate2:sa:marker2:bdensity:data? |
Return Type |
Numeric |
Not applicable |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the frequency span used by Power Density to normalize the power. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<num> |
Choose a span. |
Examples |
CALC:SA:MARK:BDEN:EQSPan 1e6 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:EQSPan? |
Return Type |
Numeric |
1 MHz |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the state of the band density noise marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<bool> |
Choose from: 0 - OFF - Turn band density noise marker OFF. 1 - ON - Turn band density noise marker ON. |
Examples |
'Select the measurement CALC2:PAR:SEL "M2SA_CH2_A" 'Create marker3 on that measurement CALC2:MARK3 ON 'Make it a band density noise marker CALC:SA:MARK:BDEN:NOIS:STAT 1 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:NOISe? |
Return Type |
Boolean |
0 |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) or N524xB models with Option S93070xB (Read-Write) Sets and reads the NPR density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<bool> |
Choose from: 0 - OFF - Turn band density marker OFF. 1 - ON - Turn band density marker ON. |
Examples |
'Select the measurement CALC2:PAR:SEL "M2SA_CH2_A" 'Create marker3 on that measurement CALC2:MARK3 ON 'Make it a band density noise marker CALC2:SA:MARK3:BDEN:NPR:STAT 1 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:NPR[:STATe]? |
Return Type |
Boolean |
0 |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the bandwidth of the band power density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<num> |
Choose a bandwidth. |
Examples |
CALC:SA:MARK:BDEN:POW:BW 1e6 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:POWer:BW? |
Return Type |
Numeric |
1 MHz |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the state of the band power density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<bool> |
Choose from: 0 - OFF - Turn band power density marker OFF. 1 - ON - Turn band power density marker ON. |
Examples |
'Select the measurement CALC2:PAR:SEL "M2SA_CH2_A" 'Create marker3 on that measurement CALC2:MARK3 ON 'Make it a band density noise marker CALC:SA:MARK:BDEN:POW:STAT 1 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:POWer? |
Return Type |
Boolean |
0 |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the bandwidth of the band tone density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<num> |
Choose a bandwidth. |
Examples |
CALC:SA:MARK:BDEN:TONE:BW 1e6 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:TONE:BW? |
Return Type |
Numeric |
1 MHz |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the state of the band tone density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<bool> |
Choose from: 0 - OFF - Turn band tone density marker OFF. 1 - ON - Turn band tone density marker ON. |
Examples |
'Select the measurement CALC2:PAR:SEL "M2SA_CH2_A" 'Create marker3 on that measurement CALC2:MARK3 ON 'Make it a band density noise marker CALC:SA:MARK:BDEN:TONE:STAT 1 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:TONE? |
Return Type |
Boolean |
0 |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the spacing of the band tone density marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<num> |
Choose a spacing value. |
Examples |
CALC:SA:MARK:BDEN:TONE:TSP 100e6 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BDENsity:TONE:TSPacing? |
Return Type |
Numeric |
100 MHz |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-only) Returns the band power level from the band power marker. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that SA channel. If unspecified, <ch> is set to 1. |
<n> |
Band power marker number. If unspecified, <n> is set to 1. |
Examples |
CALC:SA:MARK:BPOW:DATA? calculate2:sa:marker2:bpower:data? |
Not applicable |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the frequency span of the band power marker. This area is marked by two vertical dotted lines on the screen and the marker's y-axis value is set to the measured power value. Noise and power on the same marker share the same span. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<num> |
Choose a frequency span within the frequency range of the analyzer. |
Examples |
CALC:SA:MARK:BPOW:SPAN 1e6 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BPOWer:SPAN? |
Return Type |
Numeric |
1 MHz |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and reads the state of the band power marker. This command makes a band power marker from a generic marker. The generic marker must first be created using: CALC:MARK:STATe |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<bool> |
Choose from: 0 - OFF - Turn band power marker OFF. 1 - ON - Turn band power marker ON. |
Examples |
'Select the measurement CALC2:PAR:SEL "M2SA_CH2_A" 'Create marker3 on that measurement CALC2:MARK3 ON 'Make it a band power marker CALC:SA:MARK:BPOW:STAT 1 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:BPOWer? |
Return Type |
Boolean |
0 |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-only) Returns the occupied bandwidth center frequency. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that SA channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
Examples |
CALC:SA:MARK:OCCB:CENT? calculate2:sa:marker2:occband:center? |
Not applicable |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and returns the percentage of the band power to search for. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<num> |
Percentage value. |
Examples |
CALC:SA:MARK:OCCB:PERC 99 calculate2:sa:marker2:occband:percent 99 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:OCCBand:PERCent? |
Return Type |
Numeric |
99.0 |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-only) Returns the occupied bandwidth power. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that SA channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
Examples |
CALC:SA:MARK:OCCB:POW? calculate2:sa:marker2:occband:power? |
Not applicable |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-only) Returns the occupied bandwidth span. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that SA channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
Examples |
CALC:SA:MARK:OCCB:SPAN? calculate2:sa:marker2:occband:span? |
Not applicable |
Applicable Models: All with Spectrum Analysis Options (S9x09xxA/B, S9x090A/B) (Read-Write) Sets and returns the occupied bandwidth on/off state. |
|
Parameters |
|
<ch> |
Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <ch> is set to 1. |
<n> |
Marker number. If unspecified, <n> is set to 1. |
<bool> |
Choose from: 0 - OFF - Turns occupied bandwidth OFF. 1 - ON - Turns occupied bandwidth ON. |
Examples |
CALC:SA:MARK:OCCB:STAT 1 calculate2:sa:marker2:occband:state 1 |
Query Syntax |
CALCulate<ch>:SA:MARKer<n>:OCCBand[:STATe]? |
Return Type |
Boolean |
0 Note: If occupied band state is turned ON, then Band Power or Band Noise is turned OFF. |