Installation Steps: 1 2 3 4 5 6 7
To generate signals using the N7617C Signal Studio for WLAN 2024 Update 1.0 software, you must have a properly configured PC and a properly configured instrument, as described in the following tables.
Instruments |
Requirements |
---|---|
N5186A MXG vector signal generator |
Firmware:
|
N5172B EXG X-Series RF vector signal generator |
Firmware:
Required options:
Recommended options:
Additional options to consider:
|
N5182B MXG X-Series RF vector signal generator |
Firmware:
Required options:
Recommended options:
Additional options to consider:
|
N5166B CXG RF vector signal generator |
Firmware:
|
E8267D PSG vector signal generator |
Firmware:
Required options:
Recommended options:
|
M9381A PXIe vector signal generator |
Driver:
Recommended options:
Additional options to consider:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9383A PXIe microwave signal generator (single-channel configurations) |
Driver:
Recommended options:
Additional options to consider:
|
M9383B VXG-m microwave signal generator |
Firmware:
Recommended options:
|
M9384B VXG microwave signal generator |
Firmware:
Recommended options:
|
M9484C VXG signal generator |
Firmware:
|
E6640A EXM wireless test set |
Software:
Recommended options:
Additional options to consider:
|
M9410A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9410a |
M9411A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9411a |
M9415A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9415a |
M9420A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
M9421A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
Solutions |
Instruments |
Requirements |
---|---|---|
One Signal Generator Solution for MxN MIMO (output switched between multiple waveforms in ARB memory) |
One N5172B EXG or One N5182B MXG |
N5172B EXG Firmware version B.01.70 or later Required options: N5172B-503 (9 kHz to 3 GHz frequency range) or N5172B-506 (9 kHz to 6 GHz frequency range) N5172B-653 (Internal baseband generator, 32 MSa/sec, up to 60 MHz RF bandwidth) Recommended options: N5172B-506 (9 kHz to 6 GHz frequency range) N5172B-655 (upgrade baseband generator from 60 to 120 MHz RF bandwidth) Other options to consider: N5172B-009 (internal Flash drive) N5172B-012 (LO in/out for phase coherency) N5172B-021 (upgrade baseband generator memory from 32 MSa to 256 MSa) N5172B-1EA (high power output for PA testing) N5172B-403 (calibrated AWGN for testing with noise) N5172B-UNV (enhanced dynamic range)
N5182B MXG Firmware version B.01.70 or later Required options: N5182B-503 (9 kHz to 3 GHz frequency range or N5182B-506 (9 kHz to 6 GHz frequency range) N5182B-656 (Internal baseband generator, 32 MSa/sec, up to 80 MHz RF bandwidth) Recommended options: N5182B-506 (9 kHz to 6 GHz frequency range) N5182B-657 (upgrade baseband generator from 80 to 160 MHz RF bandwidth) Other options to consider: N5182B-009 (internal Flash drive) N5182B-012 (LO in/out for phase coherency) N5182B-022 (upgrade baseband generator memory from 32 MSa to 512 MSa) N5182B-1EA (high power output for PA testing) N5182B-403 (calibrated AWGN for testing with noise) N5182B-UNV (enhanced dynamic range) |
(Two signal generators with baseband generator clock coherence, but without RF common LO) |
M numbers of N5172Bs or N5182Bs for transmitter test or N numbers of N5172Bs or N5182Bs for receiver test |
N5172B EXG Firmware version B.01.70 or later Required options: N5172B-503 (9 kHz to 3 GHz frequency range) N5172B-506 (9 kHz to 6 GHz frequency range) N5172B-653 (Internal baseband generator, 32 MSa/sec, up to 60 MHz RF bandwidth) Recommended options: N5172B-655 (upgrade baseband generator from 60 to 120 MHz RF bandwidth) Other options to consider: N5172B-009 (internal Flash drive) N5172B-012 (LO in/out for phase coherency) N5172B-021 (upgrade baseband generator memory from 32 MSa to 256 MSa) N5172B-1EA (high power output for PA testing) N5172B-403 (calibrated AWGN for testing with noise) N5172B-UNV (enhanced dynamic range)
N5182B MXG Firmware version B.01.70 or later Required options: N5182B-503 (9 kHz to 3 GHz frequency range) N5182B-506 (9 kHz to 6 GHz frequency range) N5182B-656 (Internal baseband generator, 32 MSa/sec, up to 80 MHz RF bandwidth) Recommended options: N5182B-657 (upgrade baseband generator from 80 to 160 MHz RF bandwidth) Other options to consider: N5182B-009 (internal Flash drive) N5182B-012 (LO in/out for phase coherency) N5182B-022 (upgrade baseband generator memory from 32 MSa to 512 MSa) N5182B-1EA (high power output for PA testing) N5182B-403 (calibrated AWGN for testing with noise) N5182B-UNV (enhanced dynamic range) |
(Signal generators with RF common LO and baseband generator clock coherence) |
M numbers of N5172Bs or for transmitter test or N numbers of N5172Bs or N5182Bs for receiver test |
N5172B EXG Firmware version B.01.70 or later Required options: N5172B-503 (9 kHz to 3 GHz frequency range) N5172B-506 (9 kHz to 6 GHz frequency range) N5172B-653 (Internal baseband generator, 32 MSa/sec, up to 60 MHz RF bandwidth) Recommended options: N5172B-655 (upgrade baseband generator from 60 to 120 MHz RF bandwidth) Other options to consider: N5172B-009 (internal Flash drive) N5172B-012 (LO in/out for phase coherency) N5172B-021 (upgrade baseband generator memory from 32 MSa to 256 MSa) N5172B-1EA (high power output for PA testing) N5172B-403 (calibrated AWGN for testing with noise) N5172B-UNV (enhanced dynamic range)
N5182B MXG Firmware version B.01.70 or later Required options: N5182B-503 (9 kHz to 3 GHz frequency range) N5182B-506 (9 kHz to 6 GHz frequency range) N5182B-656 (Internal baseband generator, 32 MSa/sec, up to 80 MHz RF bandwidth) Recommended options: N5182B-657 (upgrade baseband generator from 80 to 160 MHz RF bandwidth) Other options to consider: N5182B-009 (internal Flash drive) N5182B-012 (LO in/out for phase coherency) N5182B-022 (upgrade baseband generator memory from 32 MSa to 512 MSa) N5182B-1EA (high power output for PA testing) N5182B-403 (calibrated AWGN for testing with noise) N5182B-UNV (enhanced dynamic range) |
Instruments |
Requirements |
---|---|
N5186A MXG vector signal generator |
Firmware:
|
N5166B CXG RF vector signal generator |
Firmware:
|
M9381A PXIe vector signal generator |
Driver:
Recommended options:
Additional options to consider:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9381A PXIe vector signal generator (multichannel synchronization) |
Driver:
Required options: Y1299A-001 PXI multichannel/MIMO, reference solution kit
Recommended options:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9383A PXIe microwave signal generator (single-channel configurations) |
Driver:
Recommended options:
Additional options to consider:
|
M9383B VXG-m microwave signal generator |
Firmware:
Recommended options:
|
M9384B VXG microwave signal generator |
Firmware:
Recommended options:
|
M9484C VXG signal generator |
Firmware:
|
E6640A EXM wireless test set |
Software:
Recommended options:
Additional options to consider:
|
M9410A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9410a |
M9411A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9411a |
M9415A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9415a |
M9420A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
M9421A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
Solutions |
Hardware Requirements |
---|---|
80+80 MHz SISO Mx2 MIMO Mx3 MIMO Mx4 MIMO Mx5 MIMO Mx6 MIMO Mx7 MIMO Mx8 MIMO MxN MIMO (with one signal generator switching between different waveforms) |
N5172B EXG Firmware version B.01.70 or later Required options: N5172B-503 (9 kHz to 3 GHz frequency range) or N5172B-506 (9 kHz to 6 GHz frequency range) N5172B-653 (Internal baseband generator, 32 MSa/sec, up to 60 MHz RF bandwidth) Recommended options: N5172B-506 (9 kHz to 6 GHz frequency range) N5172B-655 (upgrade baseband generator from 60 to 120 MHz RF bandwidth) Other options to consider: N5172B-009 (internal Flash drive) N5172B-012 (LO in/out for phase coherency) N5172B-021 (upgrade baseband generator memory from 32 MSa to 256 MSa) N5172B-1EA (high power output for PA testing) N5172B-403 (calibrated AWGN for testing with noise) N5172B-UNV (enhanced dynamic range)
N5182B MXG Firmware version B.01.70 or later Required options: N5182B-503 (9 kHz to 3 GHz frequency range or N5182B-506 (9 kHz to 6 GHz frequency range) N5182B-656 (Internal baseband generator, 32 MSa/sec, up to 80 MHz RF bandwidth) Recommended options: N5182B-506 (9 kHz to 6 GHz frequency range) N5182B-657 (upgrade baseband generator from 80 to 160 MHz RF bandwidth) Other options to consider: N5182B-009 (internal Flash drive) N5182B-012 (LO in/out for phase coherency) N5182B-022 (upgrade baseband generator memory from 32 MSa to 512 MSa) N5182B-1EA (high power output for PA testing) N5182B-403 (calibrated AWGN for testing with noise) N5182B-UNV (enhanced dynamic range) |
Instruments |
Requirements |
---|---|
N5186A MXG vector signal generator |
Firmware:
|
N5166B CXG RF vector signal generator |
Firmware:
|
M9381A PXIe vector signal generator |
Driver:
Recommended options:
Additional options to consider:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9381A PXIe vector signal generator (multichannel synchronization) |
Driver:
Required options: Y1299A-001 PXI multichannel/MIMO, reference solution kit
Recommended options:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9383A PXIe microwave signal generator (single-channel configurations) |
Driver:
Recommended options:
Additional options to consider:
|
M9383B VXG-m microwave signal generator |
Firmware:
Recommended options:
|
M9384B VXG microwave signal generator |
Firmware:
Recommended options:
|
M9484C VXG signal generator |
Firmware:
|
E6640A EXM wireless test set |
Software:
Recommended options:
Additional options to consider:
|
M9410A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9410a |
M9411A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9411a |
M9415A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9415a |
M9420A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
M9421A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
Solutions |
Hardware Requirements |
---|---|
Mx2 MIMO Mx3 MIMO Mx4 MIMO MxN MIMO (with one signal generator switching between different waveforms) |
N5172B EXG Firmware version B.01.10 or later Required options: N5172B-503 (9 kHz to 3 GHz frequency range) or N5172B-506 (9 kHz to 6 GHz frequency range) N5172B-653 (Internal baseband generator, 32 MSa/sec, up to 60 MHz RF bandwidth) Recommended options: N5172B-506 (9 kHz to 6 GHz frequency range)
Other options to consider: N5172B-009 (internal Flash drive) N5172B-012 (LO in/out for phase coherency) N5172B-021 (upgrade baseband generator memory from 32 MSa to 256 MSa) N5172B-1EA (high power output for PA testing) N5172B-403 (calibrated AWGN for testing with noise) N5172B-UNV (enhanced dynamic range)
N5182B MXG Firmware version B.01.10 or later Required options: N5182B-503 (9 kHz to 3 GHz frequency range or N5182B-506 (9 kHz to 6 GHz frequency range) N5182B-656 (Internal baseband generator, 32 MSa/sec, up to 80 MHz RF bandwidth) Recommended options: N5182B-506 (9 kHz to 6 GHz frequency range)
Other options to consider: N5182B-009 (internal Flash drive) N5182B-012 (LO in/out for phase coherency) N5182B-022 (upgrade baseband generator memory from 32 MSa to 512 MSa) N5182B-1EA (high power output for PA testing) N5182B-403 (calibrated AWGN for testing with noise) N5182B-UNV (enhanced dynamic range) |
Instruments |
Requirements |
---|---|
N5186A MXG vector signal generator |
Firmware:
|
N5166B CXG RF vector signal generator |
Firmware:
|
M9381A PXIe vector signal generator |
Driver:
Recommended options:
Additional options to consider:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9383A PXIe microwave signal generator (single-channel configurations) |
Driver:
Recommended options:
Additional options to consider:
|
M9383B VXG-m microwave signal generator |
Firmware:
Recommended options:
|
M9384B VXG microwave signal generator |
Firmware:
Recommended options:
|
M9484C VXG signal generator |
Firmware:
|
E6640A EXM wireless test set |
Software:
Recommended options:
Additional options to consider:
|
M9410A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9410a |
M9411A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9411a |
M9415A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9415a |
M9420A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
M9421A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
Instruments |
Requirements |
---|---|
N5186A MXG vector signal generator |
Firmware:
|
N5172B EXG X-Series RF vector signal generator |
Firmware:
Required options:
Recommended options:
Additional options to consider:
|
N5182B MXG X-Series RF vector signal generator |
Firmware:
Required options:
Recommended options:
Additional options to consider:
|
N5166B CXG RF vector signal generator |
Firmware:
|
M9381A PXIe vector signal generator |
Driver:
Recommended options:
Additional options to consider:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9383A PXIe microwave signal generator (single-channel configurations) |
Driver:
Recommended options:
Additional options to consider:
|
M9383B VXG-m microwave signal generator |
Firmware:
Recommended options:
|
M9384B VXG microwave signal generator |
Firmware:
Recommended options:
|
M9484C VXG signal generator |
Firmware:
|
M9410A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9410a |
M9411A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9411a |
M9415A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9415a |
M9420A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
M9421A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
Instruments |
Requirements |
---|---|
N5186A MXG vector signal generator |
Firmware:
|
N5172B EXG X-Series RF vector signal generator |
Firmware:
Required options:
Recommended options:
Additional options to consider:
|
N5182B MXG X-Series RF vector signal generator |
Firmware:
Required options:
Recommended options:
Additional options to consider:
|
N5166B CXG RF vector signal generator |
Firmware:
|
M9381A PXIe vector signal generator |
Driver:
Recommended options:
Additional options to consider:
Limitations: The M9381A VSG has a limitation related to the Power Search and DC Cal functions, creating a time-synchronization loss. That is, the signal timing changes after a Power Search or DC Cal. When ALC is set to Off, Signal Studio automatically runs Power Search, which affects the user's trigger signal for starting waveform playback. Even though the timing alignment of the trigger signal and waveform are properly set, the Power Search function disrupts this synchronization. In these cases, use the following workarounds:
For DC Cal, run it before you download and play the waveform. Do not run DC Cal while the signal is playing, which disrupts the synchronization. |
M9383A PXIe microwave signal generator (single-channel configurations) |
Driver:
Recommended options:
Additional options to consider:
|
M9383B VXG-m microwave signal generator |
Firmware:
Recommended options:
|
M9384B VXG microwave signal generator |
Firmware:
Recommended options:
|
M9484C VXG signal generator |
Firmware:
|
M9410A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9410a |
M9411A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9411a |
M9415A VXT PXI vector transceiver |
For information on software and available options, go to www.keysight.com/find/m9415a |
M9420A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
M9421A VXT PXIe vector transceiver |
Software:
Recommended options:
Additional options to consider:
|
200 GB HDD with 2 GB free disk space at runtime (5 GB or higher recommended)
1024 x 768 screen resolution (1280 x 1024 recommended)
If you use a high-resolution display, the GUI's font size may appear too small to read. To resolve this, lower your PC's display resolution, but make sure the display scaling remains set at 100 percent, otherwise portions of the GUI will become truncated and hidden from view.
Windows 10 (64 bit):
1 GHz or faster
8 GB of memory minimum
1.5 GB hard disk space (includes 1 GB for Microsoft .NET Framework and 65 MB for the Keysight IO Libraries)
Microsoft Internet Explorer 11.0 or later
128 MB graphics memory with DirectX 9 graphics support (recommended)
Microsoft .NET Framework 4.5.2 or later
Keysight IO Libraries, version 18.0 or later
Keysight License Manager 5 (4. Downloading and Installing Keysight License Manager 5)
Keysight License Service (included with installer)
Keysight Host Processor Platform (included with installer)
Installed GPIB IO interface card, LAN interface card, or USB/GPIB interface connector
Keysight VISA
Microsoft Windows Installer version 2.0 or later