Click here to view links to Meas commands for all Measurement Classes.
Compression Tab Commands | |||
Softkey | Sub-item | SCPI | COM |
CompIn21 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
CompOut21 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
DeltaGain21 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
CompGain21 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
CompS11 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
Ref21 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
Other... | SC21 Linear Gain | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
S11 Linear Input Match | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
SC12 Linear Reverse Isolation | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
S22 Linear Output Match | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
AI1 Linear AI1 | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
AI2 Linear AI2 | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
CompIn21 Incident Power at Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
CompOut21 Output Power at Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
DeltaGain21 Gain Deviation at Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
CompGain21 Gain at Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
CompS11 Input Match at Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
RefS21 Reference Gain for Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
CompAI1 AI1 at Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
CompAI2 AI2 at Compression | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
IPwr Input pwr at DUT-IN @ IN freq | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
OPwr Out pwr at DUT-OUT @ OUT freq | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
RevIPwr Input pwr at DUT-OUT @ OUT freq | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
RevOPwr Out pwr at DUT-IN @ IN freq | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
|
S-Param Tab Commands | |||
Softkey | Sub-item | SCPI | COM |
S11 | On/Off | CALCulate:MEASure:PARameter | CreateS-Parameter |
SC21 | On/Off | CALCulate:MEASure:PARameter | CreateS-Parameter |
SC12 | On/Off | CALCulate:MEASure:PARameter | CreateS-Parameter |
S22 | On/Off | CALCulate:MEASure:PARameter | CreateS-Parameter |
Other... |
|
||
Meas Class... | CALCulate:MEASure:DEFine | CreateCustomMeasurementEx |
|
Power Tab Commands | |||
IPwr | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
OPwr | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
RevIPwr | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
RevOPwr | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
Other... |
|
||
Auxiliary Tab Commands | |||
Softkey | Sub-item | SCPI | COM |
AuxIn1 Source Port 1 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
AuxIn2 Source Port 1 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
CompAI1 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
CompAI2 | On/Off | CALCulate:MEASure:PARameter | CreateCustomMeasurementEx |
Other... |
|
||
Meas Setup Tab Commands | |||
Softkey | Sub-item | SCPI | COM |
|
|||
Correction | Channel Correction On | SENSe:CORRection[:STATe] | ErrorCorrection |
Channel Correction Off | ErrorCorrection |
||
Cal Set... |
|
|
|