Sets/queries the Downlink Power Control State setting. This parameter specifies whether to enable the Downlink Power Control for a RB test mode call. |
|
Off (0) | |
OUTPUT 714;"CALL:CLPControl:DOWNlink Off" !Sets the Downlink Power Control State to Off. |
Sets/queries the WCDMA Maximum DPCH Level setting. This parameter specifies the Maximum DPCH power that the average power of transmitted DPCH symbols over one time slot shall not exceed. |
|
-7 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:DPCHannel:LEVel:MAXimum -7" !Sets the Maximum DL Power to -7 dB. |
Sets/queries the HSDPA Maximum (F-)DPCH Level . This parameter specifies the Maximum DPCH power that the average power of transmitted DPCH symbols over one time slot shall not exceed. |
|
0 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:DPCHannel:LEVel:MAXimum:HSDPa 0" !Sets the Hsdpa Maximum (F-)DPCH Level to 0. |
Sets/queries the HSPA Maximum (F-)DPCH Level . This parameter specifies the Maximum DPCH power that the average power of transmitted DPCH symbols over one time slot should not exceed. |
|
same as setting | |
0 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:DPCHannel:LEVel:MAXimum:HSPA 0" !Sets the Hspa Maximum (F-)DPCH Level to 0. |
Sets/queries the Minimum (F-)DPCH Level setting. This parameter specifies the minimum DPCH power that the average power of transmitted DPCH symbols over one time slot should not go bellow. |
|
-18.0 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:DPCHannel:LEVel:MINimum -18" !Sets the Minimum (F-)DPCH Level to -18. |
Sets/queries the Target Quality on DTCH , which is sent to UE via the RadioBearerSetup message. |
|
Resolution: 0.01 | |
1 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:DTCHannel:TARGet 1" !Sets the BLER target value on DTCH to 1%. |
Sets/queries the Target Quality on DCCH State . |
|
0 (Off) | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:DCCHannel Off" !Sets the Target Quality on DCCH State to Off. |
Sets/queries the Target Quality on DCCH . |
|
same as setting | |
0.1 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:DCCHannel:TARGet 0.1" !Sets the Target Quality on DCCH. to 0.1%. |
Sets/queries the 0k and 12.2k RMC Data Rate. This parameter the information data rate on DL DTCH when CALL[:CELL]:CLPControl:DOWNlink:RMC012:STATe is set to On. |
|
KBPS12 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:RMC012:DRATe KBPS12" !Sets the 0k and 12.2k RMC Data Rate to 12.2k. |
This command perform to actions: 1) set the CALL[:CELL]:CLPControl:DOWNlink:RMC012:STATe to On and, 2) Set the CALL[:CELL]:CLPControl:DOWNlink:RMC012:DRATe | |
Range: KBPS12 | KBPS0 |
|
KBPS12 | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:RMC012 KBPS12" !Sets the 0k and 12.2k RMC state to On and set the data rate to 12.2k. |
This action starts the recording of Real-time Downlink Power Control Info Statistic immediately. See Start/Stop Recording DPCH Ec/Ior . | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:ECIor:RECord:STARt" !perform the recording of Realtime Downlink Power Conrol Info Statistic. |
This action stop the real-time Downlink Power Control Information statistic process. See Start/Stop Recording DPCH Ec/Ior . | |
OUTPUT 714;"CALL:CLPControl:DOWNlink:ECIor:RECord:STOP" !Stop the the realtime Downlink Power Control Infomation statistic process. |
Sets the uplink inner loop power control to decrease power in one step (see CALL[:CELL]:CLPControl:UPLink:STEPsize ). This function is only used when the UL CL power control is set to use alternating bits (see CALL[:CELL]:CLPControl:UPLink:MODE ). |
|
OUTPUT 714;"CALL:CELL:CLPCONTROL:UPLINK:IMMEDIATE:DOWN" |
Sets the uplink inner loop power control to increase power in one step (see CALL[:CELL]:CLPControl:UPLink:STEPsize ). This function is only used when the UL CL power control is set to use alternating bits (see CALL[:CELL]:CLPControl:UPLink:MODE ). |
|
OUTPUT 714;"CALL:CELL:CLPCONTROL:UPLINK:IMMEDIATE:UP" |
Sets/queries the UL CL Power Control Mode for Active Cell Operating Mode . |
|
OUTPUT 714;"CALL:CELL:CLPControl:UPLink:MODE ACTive" !Sets the uplink closed loop power control to active. |
Sets/queries UL CL Power Ctrl Algorithm . This setting can only be changed while the Cell Operating Mode is "Cell Off", or while the cell operating mode is "Active Cell" and the call status is IDLE. Attempting to change this setting while in any other mode will result in an error. |
|
OUTPUT 714;"CALL:CELL:CLPControl:UPLink:ALGorithm ALG1" ! Sets the uplink closed loop power control algorithm to 1. |
Sets/queries UL CL Power Ctrl Stepsize . This setting can only be changed while the Cell Operating Mode is "Cell Off", or while the cell operating mode is "Active Cell" and the call status is IDLE. Attempting to change this setting while in any other mode will result in an error.
This setting can only be changed when
CALL[:CELL]:CLPControl:UPLink:ALGorithm
is set to |
|
OUTPUT 714;"CALL:CLPControl:UPLink:STEPsize 2" ! Sets the uplink closed loop power control step size to 2 dB. |