CALL:FDDTest:SSCell

CALL:FDDTest:SSCell

Last updated: April 27, 2013

   
NOTE
The CALL:FDDTest:SSCell commands .

   

GPIB Command Conventions

CALL:FDDTest:SSCell:CHANnel:ADJacent

Function

Sets/queries the downlink UARFCN of the secondary serving cell.

Setting

Range: Adjacent Higher Carrier|Adjacent Lower Carrier

Query

Same as setting

*RST Setting

Adjacent Higher Carrier

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CHANnel:ADJacent HIGHer"
! Sets the downlink UARFCN of the secondary serving cell to Adjacent Higher Carrier.

CALL:FDDTest:SSCell:HSPDschannel:CCODe:CODE

Function

Sets/queries the channelization code of the first HS-PDSCH channel in FDD Test Mode. Code 0 is not allowed as it would collide with the CPICH and SCH/PCCPCH channels.

Setting

Range: 1 to 15

Query

Same as setting

*RST Setting

7

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSPDschannel:CCODe:CODE 1"
! Sets the FDD Test Mode Secondary Serving Cell First HS-PDSCH Channelization Code to 1.

CALL:FDDTest:SSCell:HSSCchannel[1]:CONFig:STATe

Function

Sets/queries the FDD Test Mode Secondary Serving Cell HSDPA/HSPA HS-SCCH 1 Channel Configuration state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel:CONFig:STATe OFF"

CALL:FDDTest:SSCell:HSSCchannel2:CONFig:STATe

Function

Sets/queries the FDD Test Mode Secondary Serving Cell HSDPA/HSPA HS-SCCH 2 Channel Configuration state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel2:CONFig:STATe OFF"

CALL:FDDTest:SSCell:HSSCchannel3:CONFig:STATe

Function

Sets/queries the FDD Test Mode Secondary Serving Cell HSDPA/HSPA HS-SCCH 3 Channel Configuration state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel3:CONFig:STATe OFF"

CALL:FDDTest:SSCell:HSSCchannel4:CONFig:STATe

Function

Sets/queries the FDD Test Mode Secondary Serving Cell HSDPA/HSPA HS-SCCH 4 Channel Configuration state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel4:CONFig:STATe OFF"

CALL:FDDTest:SSCell:OCNSource:CONFig:STATe:HSDPa

Function

Sets/queries the FDD Test Mode Secondary Serving Cell HSDPA/HSPA OCNS 1 to 6 Channel Configuration States.

Setting

Range: 1|On|0|Off

Query

Range: 0|1

*RST Setting

1 (On), 1 (On), 1 (On), 1 (On), 1 (On), 1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:OCNSource:CONFig:STATe:HSDPa 1,0,0,0,0,0"

CALL:FDDTest:SSCell:CPIChannel:LEVel:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell CPICH Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CPIChannel:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell CPICH Power Offset to -10dB. 

CALL:FDDTest:SSCell:CPIChannel:STATe:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell CPICH state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CPIChannel:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:CPIChannel[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell CPICH Level (see CALL:FDDTest:SSCell:CPIChannel:LEVel:HSDPa ) and (2) sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell CPICH state to on (see CALL:FDDTest:SSCell:CPIChannel:STATe:HSDPa ).

The query form of this command returns the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell CPICH Level.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CPIChannel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell CPICH Level to -10dB and turn its state to on. 

CALL:FDDTest:SSCell:CPIChannel:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell CPICH Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CPIChannel:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell CPICH Power Offset to -10dB. 

CALL:FDDTest:SSCell:CPIChannel[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell CPICH Level (see CALL:FDDTest:SSCell:CPIChannel:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell CPICH state to on (see CALL:FDDTest:SSCell:CPIChannel:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell CPICH Level.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CPIChannel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell CPICH Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:CPIChannel:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell CPICH state.

Setting

Range: 1|On0||Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CPIChannel:STATe:HSPA OFF"

CALL:FDDTest:SSCell:CCPChannel:PRIMary:LEVel:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell P-CCPCH/SCH Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-12 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CCPChannel:PRIMary:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell P-CCPCH/SCH Power Offset to -10dB. 

CALL:FDDTest:SSCell:CCPChannel:PRIMary:STATe:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell P-CCPCH/SCH state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1(On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CCPChannel:PRIMary:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:CCPChannel:PRIMary[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell P-CCPCH/SCH Level (see CALL:FDDTest:SSCell:CCPChannel:PRIMary:LEVel:HSDPa ) and (2) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell P-CCPCH/SCH state to on (see CALL:FDDTest:SSCell:CCPChannel:PRIMary:STATe:HSDPa ).

The query form of this command returns the UTRA FDD Test(HSDPA) Secondary Serving Cell P-CCPCH/SCH Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-12 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CCPChannel:PRIMary:HSDPa -10"
! Sets the UTRA FDD Test(HSDPA) Secondary Serving Cell P-CCPCH/SCH Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:CCPChannel:PRIMary:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell P-CCPCH/SCH Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-12 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CCPChannel:PRIMary:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell P-CCPCH/SCH Power Offset to -10dB. 

CALL:FDDTest:SSCell:CCPChannel:PRIMary:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell P-CCPCH/SCH state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CCPChannel:PRIMary:STATe:HSPA OFF"

CALL:FDDTest:SSCell:CCPChannel:PRIMary[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell P-CCPCH/SCH Level (see CALL:FDDTest:SSCell:CCPChannel:PRIMary:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell P-CCPCH/SCH state to on (see CALL:FDDTest:SSCell:CCPChannel:PRIMary:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell P-CCPCH/SCH Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-12 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:CCPChannel:PRIMary:HSPA -10"
! Sets the UTRA FDD Test(HSPA) Secondary Serving Cell P-CCPCH/SCH Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:PICHannel:LEVel:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell PICH Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:PICHannel:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell PICH Power Offset to -10dB. 

CALL:FDDTest:SSCell:PICHannel:STATe:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell PICH state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:PICHannel:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:PICHannel[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell PICH Level (see CALL:FDDTest:SSCell:PICHannel:LEVel:HSDPa ) and (2) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell PICH state to on (see CALL:FDDTest:SSCell:PICHannel:STATe:HSDPa ).

The query form of this command returns the UTRA FDD Test(HSDPA) Secondary Serving Cell PICH Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:PICHannel:HSDPa -10"
! Sets the UTRA FDD Test(HSDPA) Secondary Serving Cell PICH Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:PICHannel:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell PICH Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:PICHannel:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell PICH Power Offset to -10dB. 

CALL:FDDTest:SSCell:PICHannel:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell PICH state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:PICHannel:STATe:HSPA OFF"

CALL:FDDTest:SSCell:PICHannel[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell PICH Level (see CALL:FDDTest:SSCell:PICHannel:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell PICH state to on (see CALL:FDDTest:SSCell:PICHannel:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell PICH Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:PICHannel:HSPA -10"
! Sets the UTRA FDD Test(HSPA) Secondary Serving Cell PICH Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSPDschannel:LEVel:HSDPa

Function

Sets/queries the FDD Test Mode(HSDPA) Secondary Serving Cell HS-PDSCH Power Offset.

This parameter controls the total amount of power in all HS-PDSCHs of the carrier 2 in FDD Test Mode while HSDPA is active. The power will be equally split between all the active carrier 2 HS-PDSCHs during a sub-frame.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-3 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSPDschannel:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-PDSCH Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSPDschannel:STATe:HSDPa

Function

Sets/queries the FDD Test Mode(HSDPA) Secondary Serving Cell HS-PDSCH state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSPDschannel:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:HSPDschannel[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the FDD Test(HSDPA) Secondary Serving Cell HS-PDSCH Level (see CALL:FDDTest:SSCell:HSPDschannel:LEVel:HSDPa ) and (2) sets the FDD Test(HSDPA) Secondary Serving Cell HS-PDSCH state to on (see CALL:FDDTest:SSCell:HSPDschannel:STATe:HSDPa ).

The query form of this command returns the FDD Test(HSDPA) Secondary Serving Cell HS-PDSCH Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-3 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSPDschannel:HSDPa -10"
! Sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-PDSCH Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSPDschannel:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-PDSCH Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-3 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSPDschannel:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-PDSCH Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSPDschannel:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-PDSCH state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSPDschannel:STATe:HSPA OFF"

CALL:FDDTest:SSCell:HSPDschannel[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-PDSCH Level (see CALL:FDDTest:SSCell:HSPDschannel:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-PDSCH state to on (see CALL:FDDTest:SSCell:HSPDschannel:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell HS-PDSCH Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-3 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSPDschannel:HSPA -10"
! Sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-PDSCH Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel1:LEVel:HSDPa

Function

Sets/queries the FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 1 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel1:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 1 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel1:STATe:HSDPa

Function

Sets/queries the FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 1 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel1:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:HSSCchannel1[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 1 Level (see CALL:FDDTest:SSCell:HSSCchannel1:LEVel:HSDPa ) and (2) sets the FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 1 state to on (see CALL:FDDTest:SSCell:HSSCchannel1:STATe:HSDPa ).

The query form of this command returns the FDD Test(HSDPA) Secondary Serving Cell HS-SCCH Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel:HSDPa -10"
! Sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 1 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel1:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 1 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel1:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 1 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel1:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 1 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel1:STATe:HSPA OFF"

CALL:FDDTest:SSCell:HSSCchannel1[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 1 Level (see CALL:FDDTest:SSCell:HSSCchannel1:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 1 state to on (see CALL:FDDTest:SSCell:HSSCchannel1:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 1 Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-10 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel:HSPA -10"
! Sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 1 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel2:LEVel:HSDPa

Function

Sets/queries the FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 2 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel2:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 2 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel2:STATe:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 2 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel2:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:HSSCchannel2[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 2 Level (see CALL:FDDTest:SSCell:HSSCchannel2:LEVel:HSDPa ) and (2) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 2 state to on (see CALL:FDDTest:SSCell:HSSCchannel2:STATe:HSDPa ).

The query form of this command returns the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 2 Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel2:HSDPa -10"
! Sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 2 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel2:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 2 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel2:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 2 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel2:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 2 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel2:STATe:HSPA OFF"

CALL:FDDTest:SSCell:HSSCchannel2[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 2 Level (see CALL:FDDTest:SSCell:HSSCchannel2:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 2 state to on (see CALL:FDDTest:SSCell:HSSCchannel2:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 2 Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel2:HSPA -10"
! Sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 2 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel3:LEVel:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 3 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel3:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 3 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel3:STATe:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 3 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel3:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:HSSCchannel3[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 3 Level (see CALL:FDDTest:SSCell:HSSCchannel3:LEVel:HSDPa ) and (2) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 3 state to on (see CALL:FDDTest:SSCell:HSSCchannel3:STATe:HSDPa ).

The query form of this command returns the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 3 Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel3:HSDPa -10"
! Sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 3 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel3:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 3 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel3:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 3 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel3:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 3 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel3:STATe:HSPA OFF"

CALL:FDDTest:SSCell:HSSCchannel3[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 3 Level (see CALL:FDDTest:SSCell:HSSCchannel3:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 3 state to on (see CALL:FDDTest:SSCell:HSSCchannel3:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 3 Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel3:HSPA -10"
! Sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 3 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel4:LEVel:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 4 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel4:LEVel:HSDPa -10"
! Sets the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 4 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel4:STATe:HSDPa

Function

Sets/queries the UTRA FDD Test Mode(HSDPA) Secondary Serving Cell HS-SCCH 4 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel4:STATe:HSDPa OFF"

CALL:FDDTest:SSCell:HSSCchannel4[:SLEVel]:HSDPa

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 4 Level (see CALL:FDDTest:SSCell:HSSCchannel4:LEVel:HSDPa ) and (2) sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 4 state to on (see CALL:FDDTest:SSCell:HSSCchannel4:STATe:HSDPa ).

The query form of this command returns the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 4 Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel4:HSDPa -10"
! Sets the UTRA FDD Test(HSDPA) Secondary Serving Cell HS-SCCH 4 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:HSSCchannel4:LEVel:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 4 Power Offset.

Setting

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel4:LEVel:HSPA -10"
! Sets the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 4 Power Offset to -10dB. 

CALL:FDDTest:SSCell:HSSCchannel4:STATe:HSPA

Function

Sets/queries the UTRA FDD Test Mode(HSPA) Secondary Serving Cell HS-SCCH 4 state.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

1 (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel4:STATe:HSPA OFF"

CALL:FDDTest:SSCell:HSSCchannel4[:SLEVel]:HSPA

Function

The setting form of this command performs two functions: (1) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 4 Level (see CALL:FDDTest:SSCell:HSSCchannel4:LEVel:HSPA ) and (2) sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 4 state to on (see CALL:FDDTest:SSCell:HSSCchannel4:STATe:HSPA ).

The query form of this command returns the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 4 Level.

Query

Range:-20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1dB

Query

Same as setting

*RST Setting

-15 dB (On)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSSCchannel4:HSPA -10"
! Sets the UTRA FDD Test(HSPA) Secondary Serving Cell HS-SCCH 4 Level to -10 dB and turns its state on.

CALL:FDDTest:SSCell:OCNSource:POFFset:HSDPa

Function

Sets/queries the FDD Test Mode Secondary Serving Cell HSDPA/HSPA orthogonal channel noise simulator (OCNS) 1 to 6 Power Offsets.

Setting

Range: -20 to 0 dB

Resolution: 0.01 dB

Increment: 0.1 dB

Query

Same as setting

*RST Setting

0 dB

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:OCNSource:POFFset:HSDPa 0,0,0,0,0,0"

CALL:FDDTest:SSCell:HRNTi

Function

Sets/queries the primary H-RNTI of the secondary serving cell.

If you attempt to set this parameter to a value that is same as any FDD Test Mode HS-SCCH Alternate H-RNTI, the attempt will be rejected and the test set will post a error message.

Setting

Range: 0 to 0xFFFF.

Query

Same as setting

*RST Setting

0xAAAA

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HRNTi `AAAA'"
! Sets the primary H-RNTI of the secondary serving cell to AAAA.

CALL:FDDTest:SSCell:HSDSchannel:UDEFined:MACEHS:TBSTable:ALIGnment

Function

Sets/queries the FDD Test Mode Secondary Serving Cell MAC-ehs HS-DSCH TB size table when FDD Test User Def Secondary Cell 64QAM State is "Off".

Setting

Range: BIT | OCTet

Query

Same as setting

*RST Setting

OCTet

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSDSchannel:UDEFined:MACEHS:TBSTable:ALIGnment BIT"
! Sets the FDD Test Mode Secondary Serving Cell MAC-ehs HS-DSCH TB size table to Bit-aligned.

CALL:FDDTest:SSCell:HSDSchannel:UDEFined:QAM64:STATe

Function

Sets/queries whether the 64QAM encoding format should be used for the secondary serving cell HS-SCCH.

Setting

Range: 1|On|0|Off

Query

Same as setting

*RST Setting

0 (Off)

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSDSchannel:UDEFined:QAM64:STATe ON"
! Returns the FDD Test Mode Secondary Serving Cell 64QAM configured to on.

CALL:FDDTest:SSCell:HSDSchannel:UDEFined:ITTI[:INTerval]

Function

Sets/queries the absolute inter-TTI interval between transmitting blocks to the UE on the secondary serving cell HS-PDSCH.

Setting

Range: 1 to 8

Query

Same as setting

*RST Setting

3

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSDSchannel:UDEFined:ITTI 2"
! Sets the FDD Test Mode Secondary Serving Cell Inter-TTI Interval to 2.

CALL:FDDTest:SSCell:HSDSchannel:UDEFined:MODulation[:TYPE]

Function

Sets/queries the modulation type of the currently active HS-PDSCH channels on the secondary serving cell and is used to determine the actual transport block size.

Setting

Range: QPSK | QAM16 | QAM64

Query

Same as setting

*RST Setting

QPSK

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSDSchannel:UDEFined:MODulation QPSK"
! Sets the FDD Test Mode Secondary Serving Cell Modulation Type to QPSK.

CALL:FDDTest:SSCell:HSDSchannel:UDEFined:TBSize:INDex

Function

Sets/queries the transport block size index of the secondary serving cell and determine the actual transport block size.

Setting

Range: 0 to 62

Query

Same as setting

*RST Setting

62

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSDSchannel:UDEFined:TBSize:INDex 62"
! Sets the FDD Test Mode Secondary Serving Cell Transport Block Size Index to 10.

CALL:FDDTest:SSCell:HSDSchannel:UDEFined:HSPDschannel:COUNt

Function

Sets/queries how many HS-PDSCHs are active on the secondary serving cell.

Setting

Range: 1 to 15

Query

Same as setting

*RST Setting

5

Requirements

Test Application Revision: A.19.00 and above, with the required feature license.
Lab Application Revision: H.01.00 and above.

Programming Example

 
OUTPUT 714;"CALL:FDDTest:SSCell:HSDSchannel:UDEFined:HSPDschannel:COUNt 1"
! Sets FDD Test Mode Secondary Serving Cell Number of HS-PDSCHs to 1.