CALL:MS:POWer

CALL:MS:POWer

Last updated: January 15, 2009

GPIB Command Conventions

CALL:MS:POWer:TARGet[: AMPLitude]?

Function

Sets/queries the expected power level from the UE (mobile station). See UE Target Power .

Query

Range: -61 dBm to +28 dBm

Resolution: 1 dB

*RST Setting

-5 dBm

Requirements

Test or Lab Application Revision: A.01 and above

Programming Example

 
OUTPUT 714;"CALL:MS:POWER:TARGET:AMPLITUDE -20"