Last updated: January 16, 2009
This section is only applicable to the lab application or feature-licensed test application.
Queries the fast device tune measurement results. Results are returned in the following order:
|
|
|
|
Test Application Revision: A.09 and above, with the required feature license |
|
OUTPUT 714;"FETCh:CFDTune:ALL?" !Returns integrity, number of frequency steps, number of power steps, !Number of MS Tx Power steps measured, followed by a comma-separated list of !400 MS Tx Power results. |
Queries the measurement integrity indicator for the fast device tune measurement. Zero indicates a normal measurement. See Integrity Indicator for information about non-zero integrity results. |
|
Range: See Integrity Indicator |
|
Test Application Revision: A.09 and above, with the required feature license |
|
OUTPUT 714;"FETCh:CFDTune:INTegrity?" !Queries the inegrity indicator for the fast device tune results. |