Selected Pulses (Pulse)
Menu Path:
Specifies the time sample portion associated with the current acquisition detected signal pulses made available for viewing within the synchronized Amplitude, Phase, and FM Frequency Modulation versus time trace results.
- Select All Pulses
- All valid pulse detections, limited to Maximum Pulse Count if enabled, are reported within synchronized Amplitude, Phase, and FM versus time trace results
- Select Subset
- Only a selected range of valid pulse detections are reported within synchronized Amplitude, Phase, and FM versus time trace results, as determined by user specified Starting Pulse and Number of Pulses parameters.
- Starting Pulse
- Selects the first detected pulse index to include within the synchronized time trace results .
- Number of Pulses
- Selects the number of valid detected pulses to include within the synchronized time trace results .
- Starting Pulse
- Only a selected range of valid pulse detections are reported within synchronized Amplitude, Phase, and FM versus time trace results, as determined by user specified Starting Pulse and Number of Pulses parameters.
- Sub-Part Selection
- You can choose to limit the displayed time sample portion within the synchronized Amplitude, Phase, and FM versus time trace results to the following selected pulse range sub-part samples.
- Entire Pulse: Displays time trace results for the entire pulse Rise /Top /Fall time samples. Trace highlighting includes Rise / Top / Fall, plus Ripple Analysis samples.
- On Part: Displays time trace results for On part time samples only. Trace highlighting is limited to On part samples only.
- Top Part: Displays time trace results for Top part time samples only. Trace highlighting limited to Top part samples only.
- Frequency / Phase Analysis: Displays time trace results for user specified Frequency / Phase Analysis Width time samples only. Trace highlighting is limited to Frequency / Phase Analysis Width samples only.
- Ripple Analysis: Displays time trace results for the specified Ripple Analysis Width time samples only. Trace highlighting is limited to Ripple Analysis Width samples only.
- Pulse-to-Pulse Analysis: Displays time trace results for user specified Pulse-to-Pulse Analysis time samples only. Trace highlighting limited to Pulse-to-Pulse Analysis samples only.
- Rising Edge: Displays time trace results for Rising Edge analysis time samples only, as determined from the specified Lower (%) and Upper (%) Rising Time Thresholds. Trace highlighting is limited to Rising Edge analysis samples only.
- Falling Edge: Displays time trace results for Falling Edge analysis time samples only, as determined from the specified Lower (%) and Upper (%) Falling Time Thresholds. Trace highlighting is limited to Falling Edge analysis samples only.
- You can choose to limit the displayed time sample portion within the synchronized Amplitude, Phase, and FM versus time trace results to the following selected pulse range sub-part samples.
- Default Settings:
- Default selection (Selected Pulses): Select All Pulses
- Default value (Starting Pulse): 1
- Default value (Number of Pulses): 1
- Default selection (Sub-Part Selection): Entire Pulse
See Also
Include Extra Data Before and After