Meas Commands - Gain Compression Converters Measurement Class

Click here to view links to Meas commands for all Measurement Classes.

Compression

S-Param

Power

Auxiliary

Meas
Setup

Compression Tab Commands
Softkey Sub-item SCPI

COM

CompIn21 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompOut21 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

DeltaGain21 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompGain21 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompS11 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

Ref21 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

Other... SC21 Linear Gain CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

S11 Linear Input Match CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

SC12 Linear Reverse Isolation CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

S22 Linear Output Match CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

AI1 Linear AI1 CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

AI2 Linear AI2 CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompIn21 Incident Power at Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompOut21 Output Power at Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

DeltaGain21 Gain Deviation at Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompGain21 Gain at Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompS11 Input Match at Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

RefS21 Reference Gain for Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompAI1 AI1 at Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompAI2 AI2 at Compression CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

IPwr Input pwr at DUT-IN @ IN freq CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

OPwr Out pwr at DUT-OUT @ OUT freq CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

RevIPwr Input pwr at DUT-OUT @ OUT freq CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

RevOPwr Out pwr at DUT-IN @ IN freq CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

S-Param Tab Commands
Softkey Sub-item SCPI

COM

S11 On/Off CALCulate:MEASure:PARameter

CreateS-Parameter

SC21 On/Off CALCulate:MEASure:PARameter

CreateS-Parameter

SC12 On/Off CALCulate:MEASure:PARameter

CreateS-Parameter

S22 On/Off CALCulate:MEASure:PARameter

CreateS-Parameter

Other...    

 

Meas Class...   CALCulate:MEASure:DEFine

CreateCustomMeasurementEx

Power Tab Commands
IPwr On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

OPwr On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

RevIPwr On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

RevOPwr On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

Other...    

 

Auxiliary Tab Commands
Softkey Sub-item SCPI

COM

AuxIn1 Source Port 1 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

AuxIn2 Source Port 1 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompAI1 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

CompAI2 On/Off CALCulate:MEASure:PARameter

CreateCustomMeasurementEx

Other...    

 

Meas Setup Tab Commands
Softkey Sub-item SCPI

COM

Conversions

   

 

Correction Channel Correction On SENSe:CORRection[:STATe]

ErrorCorrection

Channel Correction Off

SENSe:CORRection[:STATe]

ErrorCorrection

Cal Set...

 

 

Smart Cal...

 

 

Trace Hold

   

 

Equation Editor...

   

 

Memory...

 

 

 

Time Domain...

 

 

 

Pulse Setup...