SYSTem:CONF:EDEVice:PULSe Commands


Configures and makes settings for an external Keysight 81110A Pulse Generator.

SYST:CONF:EDEVice:PULSe

     | CHAN

     | HAMP

     | LAMP

     | LIMP

     | MMODe

     | SIMP

Click on a keyword to view the command details.

See Also


SYSTem:CONFigure:EDEVice:PULSe:CHAN <name>,<value>

Applicable Models: All

(Read-Write) Sets and returns the output channel of the pulse generator.

Parameters

 

<name>

String - Name of the external pulse generator.

<value>

Pulse Generator output port. Choose from 1 or 2.

Examples

SYST:CONF:EDEV:PULS:CHAN "81110",1

system:configure:edevice:pulse:chan "myPG",2

Query Syntax

SYSTem:CONFigure:EDEVice:DC:PULSe:CHAN? <name>

Return Type

Numeric

Default

1


SYSTem:CONFigure:EDEVice:PULSe:HAMP <name>,<value>

Applicable Models: All

(Read-Write) Sets and returns the High amplitude (voltage) of the pulse generator.

Parameters

 

<name>

String - Name of the external pulse generator.

<value>

Pulse Generator high amplitude voltage.

Examples

SYST:CONF:EDEV:PULS:HAMP "81110",3

system:configure:edevice:pulse:HAMP "myPG",4

Query Syntax

SYSTem:CONFigure:EDEVice:DC:PULSe:HAMP? <name>

Return Type

Numeric

Default

5


SYSTem:CONFigure:EDEVice:PULSe:LAMP <name>,<value>

Applicable Models: All

(Read-Write) Pulse Generator low amplitude voltage.

Parameters

 

<name>

String - Name of the external pulse generator.

<value>

Pulse Generator low amplitude voltage.

Examples

SYST:CONF:EDEV:PULS:LAMP "81110",.2

system:configure:edevice:pulse:lamp "myPG",1

Query Syntax

SYSTem:CONFigure:EDEVice:DC:PULSe:LAMP? <name>

Return Type

Numeric

Default

0


SYSTem:CONFigure:EDEVice:PULSe:LIMP <name>,<value>

Applicable Models: All

(Read-Write) Sets and returns the load impedance of the pulse generator.

Parameters

 

<name>

String - Name of the external pulse generator.

<value>

Pulse generator load impedance.

Examples

SYST:CONF:EDEV:PULS:LIMP "81110",52

system:configure:edevice:pulse:limp "myPG",49

Query Syntax

SYSTem:CONFigure:EDEVice:DC:PULSe:LIMP? <name>

Return Type

Numeric

Default

50


SYSTem:CONFigure:EDEVice:PULSe:MMODe <name>,<bool>

Applicable Models: All

(Read-Write) Sets and returns the Master (On/Off) setting of the external pulse generator. The ON setting allows the external pulse generator to set the master clock frequency for the other pulse generators.

Parameters

 

<name>

String - Name of the external pulse generator.

<bool>

Master setting. Choose from:

ON or 1 - Use the external pulse generator becomes the master clock frequency.

OFF or 0 - Use the internal pulse generator as the master clock frequency.

Examples

SYST:CONF:EDEV:PULS:MMOD "81110",OFF

system:configure:edevice:pulse:mmode "myPG",1

Query Syntax

SYSTem:CONFigure:EDEVice:DC:PULSe:MMODe? <name>

Return Type

Boolean

Default

OFF or 0


SYSTem:CONFigure:EDEVice:PULSe:SIMP <name>,<value>

Applicable Models: All

(Read-Write) Sets and returns the source impedance of the pulse generator.

Parameters

 

<name>

String - Name of the external pulse generator.

<value>

Pulse generator source impedance.

Examples

SYST:CONF:EDEV:PULS:SIMP "81110",52

system:configure:edevice:pulse:simp "myPG",49

Query Syntax

SYSTem:CONFigure:EDEVice:DC:PULSe:SIMP? <name>

Return Type

Numeric

Default

50