Minimum required FCA (SMC and VMC) Cal commands

    SCPI and COM examples.

    Create Cal object

    None

    Begin Cal

    GUID:INITiate

    Set connector type for each port

    GUID:CONN:PORT:SEL

    Set Cal Kit for each port

    GUID:CKIT:PORT:SEL

    Returns the number of steps required by the Calibration

    GUID:STEPs?

    Returns the step description.

    GUID:DESC?

    Measure a standard

    GUID:ACQ

    Generate Error Terms

    GUID:SAVE

    Optional FCA (SMC and VMC) commands

    See SMC and VMC specific optional commands

    Set THRU method

    SENS:CORR:COLL:GUID:PATH:TMEThod

    Sets ECAL auto-orientation ON or OFF

    SENS:CORR:PREF:ECAL:ORI

    Sets ECAL port map when orientation is off.

    SENS:CORR:PREF:ECAL:PMAP

    Perform or Omit Isolation

    SENS:CORR:COLL:GUID:ISOL

    SMC Optional commands

    SMC network embed/deembed

    GUID:SMC:FSIM:NETW:MODE

    SMC filename

    GUID:SMC:FSIM:NETW:FIL

    Import existing Phase Ref Cal or Source Power Cal

    SENS:CORR:COLL:GUID:SMC:IMPort

    Use Thru or perform separate power cals

    SENS:CORR:COLL:GUID:SMC:PWRC:SEP

    Include Reverse SC12 sweep

    SENS:MIX:REVerse

    Include input/output match correction

    CALC:CORR:TYPE

    Use Nominal Incident Power

    SENS:MIX:INP:POW:USEN

    Enable LO Power Cal

    SENS:CORR:COLL:GUID:SMC:LO:PCAL

    Save to s2p and s2px file

    MMEM:STOR

     

     

     

    Gain Compression Setup

    Create a GCA Meas

    CALC:CUST:DEF

    Change a GCA Parameter

    CALC:CUST:MOD

    Sweep Type

    SENS:SWE:TYPE

    Number of frequency points

    SENS:GCS:SWE:FREQ:POIN

    Number of power points

    SENS:GCS:SWE:POW:POIN

    Maximum number of points

    None

    Total number of points

    None

    Acquisition mode

    SENS:GCS:AMOD

    Smart tolerance

    SENS:GCS:SMAR:TOL

    Smart Iterations

    SENS:GCS:SMAR:MIT

    Smart settling time

    SENS:GCS:SMAR:STIM

    Smart show iterations

    SENS:GCS:SMAR:SIT

    Read compression failures

    SENS:GCS:SFA?

    Write port map

    SENS:GCS:PMAP

    Read Port Map (Input)

    SENS:GCS:PMAP:INP

    Read Port Map (Output)

    SENS:GCS:PMAP:OUTP

    End of Sweep

    SENS:GCS:EOS

    Linear input power

    SENS:GCS:POW:LIN:INP:LEV

    Reverse Power

    SENS:GCS:POW:REV:LEV

    Start power

    SENS:GCS:POW:STAR:LEV

    Stop power

    SENS:GCS:POW:STOP:LEV

    Compression algorithm

    SENS:GCS:COMP:ALG

    Compression Level

    SENS:GCS:COMP:LEV

    Backoff Level

    SENS:GCS:COMP:BACK:LEV

    X Delta

    SENS:GCS:COMP:DELT:X

    Y Delta

    SENS:GCS:COMP:DELT:Y

    Saturation level

    SENS:GCS:COMP:SAT:LEV

    Interpolation

    SENS:GCS:COMP:INT

    Safe Sweep enable

    SENS:GCS:SAFE:ENAB

    Safe Sweep coarse

    SENS:GCS:SAFE:CPAD

    Safe Sweep fine

    SENS:GCS:SAFE:FPAD

    Safe Sweep threshold

    SENS:GCS:SAFE:FTHR

    Safe Sweep max power

    SENS:GCS:SAFE:MLIM

    Read GCA Data

    Read all GCA data

    CALC:GCData:DATA

    Read real GCA data

    CALC:GCData:REAL

    Read imaginary GCA data

    CALC:GCData:IMAG

    Read number of iterations

    CALC:GCD:ITER

    Gain Compression Analysis

    Enable a compression analysis trace

    CALC:GCM:ANAL:ENAB

    AnalysisEnable

    Set CW frequency

    CALC:GCM:ANAL:CWFR

    AnalysisCWFreq

    Set to discrete or interpolated CW frequencies

    CALC:GCM:ANAL:ISD

    AnalysisIsDiscreteFreq

    Sets X-axis display

    CALC:GCM:ANAL:XAX

    AnalysisXAxis

    GCA Cal

    Read about GCA Cal

    Gain Compression Cal

    GainCompressionCal

    Set power for source power cal

    SENS:CORR:GCS:POW

    PowerLevel

    Set connector type for power sensor.

    SENS:CORR:GCS:SENS:CONN

    PowerSensorConnectorType

    Set cal kit for power sensor connector.

    SENS:CORR:GCS:SENS:CKIT

    PowerSensorCalKitType

    Guided Cal commands

    Sens:Corr:Coll:Guided

    GuidedCalibration

     

     


    Last Modified:

    11-Sep-2013

    Added ECal Extrap

    14-Nov-2012

    Added IMD/IMS Leveling - removed two superseded

    9-Nov-2012

    Added SMC s2p save

    9-May-2012

    Added GC Iterations

    17-Apr-2012

    Added IMD Role

    10-Jan-2011

    Changed FCA commands (9.33)

    9-Sep-2010

    Added GCx (A.09.30)

    17-Mar-2010

    Added integ pulse

    9-Dec-2009

    Added Pulse

    24-Mar-2009

    Added Phase Swp (8.5) and IMDx

    25-Sep-2008

    Added IMD

    15-May-2008

    Added iTMSA

    11-Apr-2008

    Added GCA Power sensor

    6-Mar-2008

    Fixed Noise source temp

    23-Oct-2007

    Added all Apps