File  |  Instrument  |  Response  |  Stimulus  |  Utility  |  Cal  |  Apps  |  Remote ONLY


 

Get and Put Data:  Measurement | Cal | Power Cal | Custom | Power Range
Other:
 GPIB Pass-through | VISA Pass-through | Capabilities | Status/Events | Rear-panel | FIFO and FastCW | Speed up Measurements! | Ground Loop

Description

SCPI

Get X-Axis values (variant)

CALCulate:MEASure:X:VALues?

Get X-Axis values (typed)

None

Set/get X-axis for trace

CALCulate:MEASure:X:AXIS

Set/get the X-Axis domain

CALCulate:MEASure:X:AXIS:DOMain

Get X-Axis values (Meas object)

None

Get Measurement Data FROM the Analyzer

Get typed complex data from the specified location.

Returned in two arrays.

None

Get typed NAComplex data from the specified location.

Returned in one array.

None

Get typed data pairs from the specified location.

Returned in two arrays.

None

Get typed scalar data from the specified location.

Returned in one array.

None

Get variant data from the specified location in a SPECIFIED FORMAT.

Returned in one array.

None

Get receiver data

CALCulate:MEASure:RDATA?

Specifies ASCII or REAL type for data transfers

Format:Data

Get complex or formatted data from the measurement or memory result buffer

CALCulate:MEASure:DATA

Get the formatted data array of multiple traces of the selected channel.

CALCulate:DATA:MFData

Get the corrected data array of multiple traces of the selected channel.

CALCulate:DATA:MSData

Gets SnP data for the specified ports.

CALCulate:DATA:SNP:PORTs?

Get ALL SnP data

CALCulate:DATA:SNP:PORTs?

Put Measurement Data INTO the Analyzer

Put complex data into the specified location.

None

Put typed NAComplex data into the specified location.

None

Put scalar data into the measurement result location.

None

Put complex Variant data into the specified location.

None

Put complex or formatted data into the measurement or memory result buffer

CALCulate:MEASure:DATA

Get Calibration Data FROM the Analyzer

Get complex Error Term data

None

Get variant Error Term data

SENSe:CORRection:CSET:DATA

CSET:ETERm[:DATA]?

Get variant Error Term data by text filter

CSET:ETERm:CATalog?

Get complex Standard data

None

Get variant Standard data

None

Get variant Standard data by text filter

None

Put Calibration Data INTO the Analyzer

Put complex Error Term data

None

Put variant Error Term data

SENSe:CORRection:CSET:DATA

CSET:ETERm[:DATA]

Put complex Standard data

None

Put variant Standard  data

None

Power Calibration Data

Get variant cal data

SOURce:POWer:CORRection:DATA

Get typed cal data

SOURce:POWer:CORRection:DATA

Put variant cal data

SOURce:POWer:CORRection:DATA

Put typed cal data

SOURce:POWer:CORRection:DATA

Get and Put Custom Measurement Data

Get and Put Custom data

CALCulate:MEASure:DATA

 

Capabilities

Many queries regarding the capability of a specific PNA

SYSTem:CAPabilities

PXIe module queries

SYSTem:CAPability:HARDware:MODule

Read installed options

*Opt?

 

Power Range

Set/get list of discrete frequencies corresponding to powers

SYSTem:CAPability:HARDware:POWer:DISCrete:FREQuency:LIST

Get a single max leveled power value

SYSTem:CAPability:HARDware:POWer:DISCrete:MAXimum?

Get an array of max leveled power values

SYSTem:CAPability:HARDware:POWer:DISCrete:MAXimum:LIST?

Get a single minimum leveled power value

SYSTem:CAPability:HARDware:POWer:DISCrete:MINimum?

Get an array of minimum leveled power values

SYSTem:CAPability:HARDware:POWer:DISCrete:MINimum:LIST?

Set/get name of the value for the given path element name

SYSTem:CAPability:HARDware:POWer:PATH:CONFig:ELEMent[:STATe]

Get all RF path element names

SYSTem:CAPability:HARDware:POWer:PATH:CONFig:ELEMent:CATalog?

Set/get port number for power data

SYSTem:CAPability:HARDware:POWer:PORT

Set/get type of power range data to be returned

SYSTem:CAPability:HARDware:POWer:TYPE

Get minimum of all max leveled power values

SYSTem:CAPability:HARDware:POWer:RANGe:MAXimum?

Get maximum of all minimum power values

SYSTem:CAPability:HARDware:POWer:RANGe:MINimum?

Set/get lower bound of the frequency range

SYSTem:CAPability:HARDware:POWer:RANGe:FREQuency:STARt

Set/get upper bound of the frequency range

SYSTem:CAPability:HARDware:POWer:RANGe:FREQuency:STOP

Reset all Power Range properties to default values

SYSTem:CAPability:HARDware:POWer:RESet

 

Status Commands

Status Registers

GP-IB/Status

*OPC;*WAI

GP-IB/Common_Commands

 

Events

AllowAllEvents Method

None

AllowEventCategory Method

None

AllowEventMessage Method

None

AllowEventSeverity Method

None

DisallowAllEvents Method

None

MessageText Method

None

OnCalEvent

None

OnChannelEvent

None

OnDisplayEvent

None

OnHardwareEvent

None

OnMeasurementEvent

None

OnSCPIEvent

None

OnSystemEvent

None

OnUserEvent

None

SetFailOnOverRange

None

 

Rear Panel Connector Controls

Material Handler I/O Connector

GP-IB/Control

Auxiliary IO Connector

GP-IB/Control

External Test Set Connector

GP-IB/Control

 

FIFO Data Buffer (N5264A Only)

FIFO ON|OFF

SYSTem:FIFO[:STATe]

Read number of data points

SYSTem:FIFO:DATA:COUNt?

Read data

SYSTem:FIFO:DATA?

Read data compact form

None

Clear data

SYSTem:FIFO:DATA:CLEar

Returns a specific number of bytes to read

SYST:FIFO:DATA:BYTe?

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of bytes.

SYST:FIFO:DATA:BYTe:COUNt?

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of 32-bit floating point (Float32) numbers.

 

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of 16-bit integers.

 

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of 32-bit integers.

 

 

Other N5264A Commands

FastCW

SENSe:SWEep:TYPE:FACW

Enable Point Averaging

SENSe:AVERage:MODE

Enable Point Sweep

SENSe:SWEep:GENeration:POINtsweep

Set Trace Sweep

SENSe:SWEep:TRIGger:MODE

 

Ground Loop De-embedding/Embedding commands

De-embedding

 

Sets and returns the Capacitance value

CALCulate:FSIMulator:GLOop:DEEMbed:PARameters:C

Sets and returns the Inductance value

CALCulate:FSIMulator:GLOop:DEEMbed:PARameters:L

Sets and returns the Resistance value

CALCulate:FSIMulator:GLOop:DEEMbed:PARameters:R

Turns ON or OFF De-embedding

CALCulate:FSIMulator:GLOop:DEEMbed:STATe

Specifies the circuit model type

CALCulate:FSIMulator:GLOop:DEEMbed:TYPE

Specifies the filename of the s1p file to load

CALCulate:FSIMulator:GLOop:DEEMbed:USER:FILename

Embedding

 

Sets and returns the Capacitance value

CALCulate:FSIMulator:GLOop:EMBed:PARameters:C

Sets and returns the Inductance value

CALCulate:FSIMulator:GLOop:EMBed:PARameters:L

Sets and returns the Resistance value

CALCulate:FSIMulator:GLOop:EMBed:PARameters:R

Turns ON or OFF Embedding

CALCulate:FSIMulator:GLOop:EMBed:STATe

Specifies the circuit model type

CALCulate:FSIMulator:GLOop:EMBed:TYPE

Specifies the filename of the s1p file to load

CALCulate:FSIMulator:GLOop:EMBed:USER:FILename