Step 3. Run the IV and CV Tests
To run the IV and CV test procedure:
-
Make sure that you have done all the preparation and configuration steps:
- Configure the measurement settings
-
Select the tests you want to run:
-
Install your Device Under Test (DUT) to the test chamber by using the correct B1505A or B1506A accessory. Refer to the B1505A or B1506A user guide for guidance on connecting your DUT to the test chamber.
-
Click the Start button () to start device characterization.
IV and CV device characterization plots appear on the B1506A or B1505A network analyzer screen, not on the host PC PD1000A display. The device characterization data is stored on the host PC in the output directory that you specify in the Settings > Global Settings menu.-
Click the Stop () button to stop a measurement while it is running.
- See Sample Plots for examples of the kind of output you can expect.
-
See Also:
Step 1. IV and CV Hardware Setup
Step 2. IV and CV Configure Tests and Test Settings
Additional IV and CV Test Information
Overview of the Power Device Model Generator (PEMG)