Main Tab Commands
Softkey Sub-item SCPI

COM

Smart Cal...

   

 

Other Cals

Cal All...  

 

Correction

   

 

Src Power Correct ON/OFF SOURce:POWer:CORRection[:STATe]

SourcePowerCorrection

Interpolation ON/OFF SENSe:CORRection:INTerpolate[:STATe]

InterpolateCorrection

Properties...   None

Properties

Cal Sets & Cal Kits Tab Commands
Softkey Sub-item SCPI

COM

Cal Set...

  CSET

 

Cal Set Viewer ON/OFF DISPlay:TOOL:CSET[:STATe]

None

Cal Kit...

 

 

 

ECal

 

 

 

Cal Pod...    

 

Fixtures Tab Commands
Softkey Sub-item SCPI

COM

Apply Fixtures ON/OFF CALCulate:FSIMulator:STATe

FixturingState

Power Comp... Port N

CALC:FSIM:SEND:POW:PORT:COMP

EnablePowerCompensation

Fixture Setup

Change order of operations

CALCulate:FSIMulator:SENDed:OORDer

None

2 and 4-port Extrapolate

CALCulate:FSIMulator:SNP:EXTRapolate

EnableSnPDataExtrapolation

2-Port Fixturing

Port matching ON and OFF

CALCulate:FSIMulator:SENDed:PMCircuit:STATe

PortMatchingState

Reverse ports

CALCulate:FSIMulator:SENDed:DEEM:PORT<n>:SNP:REVerse

Reverse2PortAdapter

Sets Port Matching circuit model

CALCulate:FSIMulator:SENDed:PMCircuit:PORT:TYPE

PortMatchingCktModel

Sets Port Matching 'S2P' file name

CALCulate:FSIMulator:SENDed:PMCircuit:PORT:USER:FILename

strPortMatch_S2PFile

Sets Capacitance 'C' value

CALCulate:FSIMulator:SENDed:PMCircuit:PORT:PARameters:C

PortMatching_C

Sets Conductance 'G' value

CALCulate:FSIMulator:SENDed:PMCircuit:PORT:PARameters:G

PortMatching_G

Sets Inductance 'L' value

CALCulate:FSIMulator:SENDed:PMCircuit:PORT:PARameters:L

PortMatching_L

Sets Resistance 'R' value

CALCulate:FSIMulator:SENDed:PMCircuit:PORT:PARameters:R

PortMatching_R

De-embed ON and OFF

CALCulate:FSIMulator:SENDed:DEEMbed:STATe

Port2PdeembedState

Sets De-embedding circuit model

CALCulate:FSIMulator:SENDed:DEEMbed:PORT

Port2PdeembedCktModel

Sets De-embedding 'S2P' file name

CALCulate:FSIMulator:SENDed:DEEM:PORT:USER:FILename

strPort2Pdeembed_S2PFile

Port Impedance ON and OFF

CALCulate:FSIMulator:SENDed:ZCONversion:STATe

PortArbzState

Port Z Real

CALCulate:FSIMulator:SENDed:ZCONversion:PORT:REAL

PortArbzReal

Port Z Imag

CALCulate:FSIMulator:SENDed:ZCONversion:PORT:IMAG

PortArbzImag

Port Z Real and Imag

CALCulate:FSIMulator:SENDed:ZCONversion:PORT:Z0

PortArbzZ0

Remote ONLY

Create Cal Set with De-embeded fixture removed

CSET:FIXTure:DEEMbed

Deembed

Create Cal Set with Matching network included

CSET:FIXTure:EMBed

Embed