Setup Commands - Phase Noise Measurement Class

Only the Main Setup commands corresponding to the Phase Noise measurement class are documented here. All other commands are identical to the Setup commands for the Standard measurement class and can be accessed by clicking here or by clicking on the softtabs on the graphic below.

Click here to view links to Setup commands for all Measurement Classes.

Main

Layout

System
Setup

Internal
Hardware

External
Hardware

Main Tab Commands

Softkey

Sub-item

SCPI

COM

Phase Noise Setup... Sweep Tab

 

Noise Type

SENSePN:NTYPe 

 

 

Sweep Type

SENSe:PN:SWEep:TYPE 

 

 

 

SENSe:PN:SEGMent:BWIDth[:RESolution]  

 

 

 

SENSe:PN:SEGMent:CORRelation:COUNt

 

 

 

SENSe:PN:SEGMent:COUNt?

 

 

 

SENSe:PN:SEGMent:FREQuency:STARt?

 

 

 

SENSe:PN:SEGMent:FREQuency:STOP?

 

 

Carrier Frequency

SENSe:PN:SWEep:CARRier:FREQuency

 

 

Search Once

None

 

 

Enable Search

SENSe:PN:ADJust:CONFigure:FREQuency:SEARch[:STATe]

 

 

Enable Pulse

SENSe:PN:PULSe[:STATe]

 

 

Pulse Setup.../Pulse Period/Frequency

SENSe:PN:PULSe:PERiod

 

 

Start Offset

SENSe:FREQuency:STARt

 

 

Stop Offset

SENSe:FREQuency:STOP

 

 

RBW Ratio

SENSe:PN:BWIDth[:RESolution]:RATio

 

 

XCORR Factor

SENSe:PN:CORRelation:COUNt 

 

 

Fast XCORR Mode

SENSe:PN:CORRelation:MODE 

 

 

X CORR Gain Indicator

SENSe:PN:XGINdicator[:STATe]

 

 

RF Path Tab

 

Always use Internal Reference

SENSe:PN:ROSCillator:SOURce:FIXed[:STATe]

 

 

RF 1/2 Input

:SENSe:PN:PORT

 

 

Auto Range

SENSe:PN:POWer:INPUt:LEVel:AUTO

 

 

Max Input Level

SENSe:PN:POWer:INPUt:LEVel:MAXimum

 

 

Enable Attenuator Setting

SENSe:PN:POWer:INPut:ATTenuation:AUTO

 

 

Attenuator

SENSe:PN:POWer:INPut:ATTenuation

 

 

External Mixer Setup

 

 

 

External Mixer State

None

 

 

LO Harmonic Number

None

 

 

RF > LO or RF < LO

None

 

 

LO1/2 Output Level Enable

None

 

 

LO1/2 Output Level Value

None

 

 

IF Gain IF1/2 In

None

 

 

Residual Noise

 

 

 

Number of DUT

None

 

 

Source Internal/External

None

 

 

Source 1/2 Out

None

 

 

RF 1/2 Input

None

 

 

Path Delay Compensation

 

 

 

Auto or Manual

SENSe:PN:PDELay:AUTO[:STATe]

 

 

Path Delay Value

SENSe:PN:PDELay[:VALue]

 

 

Measure Path Delay

None

 

 

Baseband

 

 

 

Input (Block Capacitor Selection)

SENSe:PN:BASeband:INPut:COUPling

 

 

Gain

SENSe:PN:BASeband:GAIN

 

 

Discharge DC Block C

SENSe:PN:BASeband:DISCharge

 

 

Source Tab (for Residual Noise)

 

State

SOURce:PN:POWer:MODE

 

 

Frequency

SENSe:PN:SOURce:FREQuency

 

 

Power

SENSe:PN:SOURce:POWer[:LEVel]

 

 

Resolution

SENSe:PN:SOURce:RESolution

 

 

Spurious Tab

 

Show Spurious Table

DISPlay:WINDow:TABLe:SPURious:ENABle

 

 

Table Sort Order

CALCulate:MEASure:PN:SPURious:SORT

 

 

Select Trace

CALCulate:MEASure:DEFine

 

 

Enable Spur Analysis

CALCulate:MEASure:PN:SPURious:ANALysis[:STATe]

 

 

Spur Sensibility

CALCulate:MEASure:PN:SPURious:SENSibility

 

 

Min. Spur Level

CALCulate:MEASure:PN:SPURious:THReshold:LEVel:MINimum

 

 

Omit Displayed Spur

CALCulate:MEASure:PN:SPURious:OMISsion[:STATe]

 

 

Threshold Table...

 

Start Freq

CALCulate:MEASure:PN:SPURious:THReshold:TABle:DATA

 

 

Lower Threshold

CALCulate:MEASure:PN:SPURious:THReshold:TABle:DATA

 

 

Upper Threshold

CALCulate:MEASure:PN:SPURious:THReshold:TABle:DATA

 

 

Add

CALCulate:MEASure:PN:SPURious:THReshold:TABle:DATA

 

 

Delete

None

 

 

Delete All

CALCulate:MEASure:PN:SPURious:THReshold:TABle:DELete

 

 

Save Table

None

 

 

Load Table

MMEMory:LOAD:PN:SPURious:THReshold

 

 

Omit User Specified Spur

CALCulate:MEASure:PN:SPURious:OSSPur[:STATe]

 

 

User Spur Table...

 

Spurious Freq

CALCulate:MEASure:PN:SPURious:OSSPur:DATA

 

 

Add

CALCulate:MEASure:PN:SPURious:OSSPur:DATA

 

 

Delete

None

 

 

Delete All

CALCulate:MEASure:PN:SPURious:OSSPur:DELete

 

 

Save Table

None

 

 

Load Table

MMEMory:LOAD:PN:SPURious:OSSPur

 

 

Integrated Noise Tab

 

Show Integrated Noise Table

DISPlay:WINDow:TABLe:INOise:ENABle

 

 

Weighting Filter Setup...

 

Frequency

None

 

 

Weighting Value

None

 

 

Add

None

 

 

Delete

None

 

 

Delete All

None

 

 

Save Table

None

 

 

Load Table

None

 

 

Select Trace

CALCulate:MEASure:DEFine

 

 

Range Specified in each CALC:MEAS:PN:INT:RANG[1-4]... command

 

 

Type CALCulate:MEASure:PN:INTegral:RANGe[1-4]:TYPE

 

 

Start CALCulate:MEASure:PN:INTegral:RANGe[1-4]:STARt

 

 

Stop CALCulate:MEASure:PN:INTegral:RANGe[1-4]:STOP

 

 

Weighting Filter CALCulate:MEASure:PN:INTegral:RANGe[1-4]:WEIGhting

 

 

Spot Noise Tab

 

Show Spot Noise Table DISPlay:WINDow:TABLe:SNOise:ENABle

 

 

Select Traces CALCulate:MEASure:DEFine

 

 

Define Spot Frequencies CALCulate:MEASure:PN:SNOise:USER[1-6]:X
CALCulate:MEASure:PN:SNOise:USER[1-6][:STATe]

 