File | Instrument | Response | Stimulus | Utility | Cal | Apps | Remote ONLY
|
Description |
SCPI |
|
---|---|---|
|
||
Create an FCA measurement |
|
|
Change an FCA measurement |
|
|
Sweep type |
|
|
Map DUT ports to PNA ports |
|
|
Read Input port map |
|
|
Read Output port map |
|
|
Avoid Spurs |
|
Optional FCA (SMC and VMC) commands |
|
Set THRU method |
|
Sets ECAL auto-orientation ON or OFF |
|
Sets ECAL port map when orientation is off. |
|
Perform or Omit Isolation |
SMC network embed/deembed |
|
SMC filename |
SENSe:CORRection:COLLect:GUIDed:SMC:FSIMulator:NETWork:FILename |
Import existing Phase Ref Cal or Source Power Cal |
|
Use Thru or perform separate power cals |
|
Include Reverse SC12 sweep |
|
Include input/output match correction |
|
Use Nominal Incident Power |
|
Enable LO Power Cal |
|
Save to s2p and s2px file |
|
Load Power Table (used with mmWave) |
Enable Phase |
|
Enable Absolute Phase |
|
Set normalize point |
|
Choose known delay or S2P |
|
Set known delay |
|
Set Cal Mixer Char S2P filename |
|
Use Phase Ref Cal Set |
Perform SMC Phase Reference Cal |
SCPI |
|
---|---|---|
Reset |
|
|
Start Freq |
|
|
Stop Freq |
|
|
Read channel number |
|
|
Read all Phase Reference IDs |
|
|
Set Phase Reference |
|
|
Set Source Attenuator |
|
|
Set Cal Set name |
None |
|
Perform Cal |
|
|
Use Phase Ref Cal Set |
|
Unknown Mixer calibration state |
|
Unknown mixer LO frequency |
|
Unknown mixer LO power |
|
Input power level to the unknown mixer |
|
Connector type and gender of your Cal Kit. |
|
Cal Kit to be used to perform the S-parameter Cal |
|
Set the ports to be calibrated. |
|
Reverse Port2 Coupler |
VMC network embed/deembed |
|
VMC filename |
SENSe:CORRection:COLLect:GUIDed:VMC:FSIMulator:NETWork:FILename |
Enable LO Power Cal |
SCPI examples. |
|
Recalculate |
|
Segment Calculate |
|
Query Count |
|
Add Segments |
|
Delete Segments |
|
Remove All Segments |
|
State |
|
Number Of Points |
|
IFBW |
|
Input Fixed Freq |
|
Input Start Freq |
|
Input Stop Freq |
|
Input Fixed/Swept |
|
Input Power |
|
Output Fixed Freq |
|
Output Start Freq |
|
Output Stop Freq |
|
Output Fixed/Swept |
|
Output (+/-) |
|
Output Power |
|
LO Fixed Freq |
|
LO Start Freq |
|
LO Stop Freq |
|
LO Fixed/Swept |
|
Input >LO |
|
LO Power |
|
IF (+/-) |
Embedded LO (used with FCA, NFX, GCX, MODX, and Swept IMDx) |
|
Embedded LO ON | OFF |
|
Select tuning point |
|
Set tuning mode |
|
Set broadband sweep span |
|
Set precise tuning tolerance |
|
Set precise tuning iterations |
|
LO delta frequency |
|
Resets tuning parameters |
|
Reset LO Delta frequency |
|
Resets the LO Frequency Delta and Tuning parameters to their default settings. |
|
Sets and returns the Noise Bandwidth for Broadband and Precise tuning sweeps. |
|
Embedded LO Diagnostics (Available with Swept IMDx using COM ONLY) |
|
Clear current diagnostic information |
|
Get result of the last tuning sweeps. |
|
Get number of tuning sweeps. |
|
Was a marker was used for a tuning sweep? |
|
Get the marker X-axis position. |
|
Get the marker annotation. |
|
Get the tuning sweep X axis annotation. |
|
Get the tuning sweep Y axis annotation. |
|
Get the Start sweep value. |
|
Get the Stop sweep value. |
|
Returns the tuning sweep parameter name. |
|
Returns the tuning sweep title. |
|
Returns the LO frequency delta from this tuning sweep |
Create a GCA Meas |
|
Change a GCA Parameter |
|
Sweep Type |
|
Number of frequency points |
|
Number of power points |
|
Maximum number of points |
None |
Total number of points |
None |
Acquisition mode |
|
Smart tolerance |
|
Smart Iterations |
|
Smart settling time |
|
Smart show iterations |
|
Read DC at compression point |
|
Read compression failures |
|
Write port map |
|
Read Port Map (Input) |
|
Read Port Map (Output) |
|
Remaps the source port to Port 1. |
|
End of Sweep |
|
Linear input power |
|
Reverse Power |
|
Start power |
|
Stop power |
|
Compression algorithm |
|
Compression Level |
|
Backoff Level |
|
X Delta |
|
Y Delta |
|
Saturation level |
|
Interpolation |
|
Set and read the desired phase to measure compression. |
|
Set and read compression format to be either magnitude, phase, or magnitude and phase. |
|
Safe Sweep enable |
|
Safe Sweep coarse |
|
Safe Sweep fine |
|
Safe Sweep threshold |
|
Safe Sweep max power |
|
Set and read the name of the external DC device. |
|
Set and read the maximum limit of the external DC device. |
|
Set and read the DC readings at the compression point in the last iteration of a smart sweep |
|
GCA/GCX Phase Commands |
|
Set and read the state of the mixer reference. |
|
Set and read the aperture to use when computing the linear input power. |
|
Set and read the state of the power smoothing. |
|
Set and read the power smoothing aperture in percent. |
|
Read all GCA data |
|
Read real GCA data |
|
Read imaginary GCA data |
|
Read number of iterations |
Enable a compression analysis trace |
|
Set CW frequency |
|
Set to discrete or interpolated CW frequencies |
|
Sets X-axis display |
Read about GCA Cal |
Gain Compression Cal |
Set power for source power cal |
|
Set connector type for power sensor. |
|
Set cal kit for power sensor connector. |
|
Guided Cal commands |
Create Noise Figure meas |
CALCulate:CUSTom:DEFine |
Change Noise Figure meas |
CALCulate:CUSTom:MODify |
Sets the number of impedance states to use |
SENSe:NOISe:IMPedance:COUNt |
Select Noise Receiver |
SENSe:NOISe:RECeiver |
Noise averaging ON and OFF |
SENSe:NOISe:AVERage:STATe |
Set averaging of noise receiver. |
SENSe:NOISe:AVERage |
Set narrowband state |
SENSe:NOISe:NARRowband |
Set bandwidth of noise receiver. |
SENSe:NOISe:BWIDth |
Set gain state of noise receiver. |
SENSe:NOISe:GAIN |
Sets the port identifier of the ECal noise tuner that is connected to the PNA Source. |
SENSe:NOISe:TUNer:INPut |
Sets the port identifier of the ECal noise tuner that is connected to the DUT. |
SENSe:NOISe:TUNer:OUTPut |
Set and read a custom noise tuner file to be used instead of the one generated automatically based on the state. |
SENSe:NOISe:TUNer:FILE:NAME |
Sets the state of the custom noise tuner file. |
SENSe:NOISe:TUNer:FILE[:STATe] |
Set the excess noise source ON or OFF. |
|
Set mechanical switches |
SENSe:PATH:CONFig:ELEMent |
Write port mapping |
SENSe:NOISe:PMAP |
Read input port mapping |
SENSe:NOISe:PMAP:INPut? |
Read output port mapping |
SENSe:NOISe:PMAP:OUTPut? |
SCPI |
||
---|---|---|
Read noise parameter SNP data |
SENSe:NOISe:SNP? |
|
Write noise parameters to SNP file |
SENSe:NOISe:SNP:SAVE |
|
Set and read the state of the thru adapter de-embedding. |
Set ENR calibration data. |
PutENRData |
|
Read ENR calibration data. |
GetENRData |
|
Get/set ID of ENR table. |
ENRID |
|
Get/set serial number of noise source. |
ENRSN |
|
Load ENR table from file. |
LoadENRFile |
|
Save ENR table to file. |
SaveENRFile |
SCPI |
COM |
|
---|---|---|
CALCulate:CUSTom:DEFine |
|
|
CALCulate:CUSTom:MODify |
|
SENSe:DIQ:FREQuency:RANGe:ADD |
|
SENSe:DIQ:FREQuency:RANGe:DELete |
|
SCPI |
||
---|---|---|---|
Frequency |
SENSe:DIQ:FREQuency:RANGe:STARt |
|
|
SENSe:DIQ:FREQuency:RANGe:STOP |
|
||
SENSe:DIQ:FREQuency:RANGe:IFBW |
|
||
Coupling |
SENSe:DIQ:FREQuency:RANGe:COUPle:STATe |
|
|
SENSe:DIQ:FREQuency:RANGe:COUPle:ID |
|
||
SENSe:DIQ:FREQuency:RANGe:COUPle:OFFSet |
|
||
SENSe:DIQ:FREQuency:RANGe:COUPle:UCONvert |
|
||
SENSe:DIQ:FREQuency:RANGe:COUPle:MULTiplier |
|
||
SENSe:DIQ:FREQuency:RANGe:COUPle:DIvisor |
|
SCPI |
|||
---|---|---|---|
|
SENSe:DIQ:PORT:STATe |
|
|
SENSe:DIQ:PORT:RANGe |
|
||
SOURce:PHASe:EXTernal:CATalog? SOURce:PHASe:EXTernal:PORT |
|
||
Power |
SENSe:DIQ:PORT:POWer:SWEep |
|
|
SENSe:DIQ:PORT:POWer:STARt |
|
||
SENSe:DIQ:PORT:POWer:STOP |
|
||
SENSe:DIQ:PORT:POWer:ALC:MODE |
|
||
SENSe:DIQ:PORT:POWer:ATTenuation |
|
||
SENSe:DIQ:PORT:POWer:ATTenuation:AUTO |
|
||
Phase |
SENSe:DIQ:PORT:PHASe:STATe |
|
|
SENSe:DIQ:PORT:PHASe:SWEep |
|
||
SENSe:DIQ:PORT:PHASe:STARt |
|
||
SENSe:DIQ:PORT:PHASe:STOP |
|
||
SENSe:DIQ:PORT:PHASe:REFerence |
|
||
SENSe:DIQ:PORT:PHASe:PARameter |
|
||
SOURce:PHASe:CONTrol:TOLerance |
|
||
SOURce:PHASe:CONTrol:ITERation |
|
||
Match Correction |
SENSe:DIQ:PORT:MATCh:STATe |
|
|
SENSe:DIQ:PORT:MATCh:TRECeiver |
|
||
SENSe:DIQ:PORT:MATCh:RRECeiver |
|
||
SENSe:DIQ:PORT:MATCh:RANGe |
|
SCPI |
||
---|---|---|
SENSe:DIQ:PARameter:DEFine |
|
|
SENSe:DIQ:PARameter:DELete |
|
|
SENSe:DIQ: PARameter:CATalog? |
|
SCPI |
||
---|---|---|
CALCulate:X:AXIS:DOMain |
|
|
CALCulate:X:AXIS |
|
SOURce:PHASe:ITERation |
|
SOURce:PHASe:STARt |
|
SOURce:PHASe:STOP |
|
SOURce:PHASe[:FIXed] |
|
SENSe:SA:COHerence:VECTor:AVERage:VALue | |
|
|
(see VSA Setup commands) |
|
|
|
SENSe:SA:LO:FREQ:FORCe (obsolete) |
|
SENSe:SA:LO:FREQ:VALue (obsoliete) |
Sets and reads the bandwidth of the band density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:BW CALCulate:SA:MARKer:BDENsity:BW |
Returns the band density level in dBm/Hz from the band density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:DATA? CALCulate:SA:MARKer:BDENsity:DATA? |
Marker to SA |
|
Read Band Power |
|
Read/Set Band Power Span |
CALCulate:MEASure:SA:MARKer:BPOWer:SPAN |
Read/Set Band Power State |
CALCulate:MEASure:SA:MARKer:BPOWer:STATe |
Sets and reads the state of the band density noise marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:NOISe[:STATe] CALCulate:SA:MARKer:BDENsity:NOISe[:STATe] |
Sets and reads the bandwidth of the band power density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:POWer:BW CALCulate:SA:MARKer:BDENsity:POWer:BW |
Sets and reads the state of the band power density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:POWer[:STATe] CALCulate:SA:MARKer:BDENsity:POWer[:STATe] |
Sets and reads the bandwidth of the band tone density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:TONE:BW CALCulate:SA:MARKer:BDENsity:TONE:BW |
Sets and reads the state of the band tone density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:TONE[:STATe] CALCulate:SA:MARKer:BDENsity:TONE[:STATe] |
Sets and reads the spacing of the band tone density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:TONE:TSPacing CALCulate:SA:MARKer:BDENsity:TONE:TSPacing |
Sets and reads the frequency span used by Power Density to normalize the power. |
CALCulate:MEASure:SA:MARKer:BDENsity:EQSPan CALCulate:SA:MARKer:BDENsity:EQSPan |
Read occupied bandwidth center frequency |
|
Set and read occupied bandwidth percentage of span |
|
Read the occupied bandwidth power. |
|
Read occupied bandwidth span |
|
Set occupied bandwidth state |
SOURce:MODulation[:STATe] |
|
SOURce:MODulation:LOAD |
|
SOURce:MODulation:AUTO:SA[:STATe] |
|
SOURce:MODulation:AUTO:IMMediate |
|
SOURce:MODulation:AUTO:NPR[:STATe] |
|
SOURce:MODulation:AUTO:NPR:GBANd |
|
SOURce:MODulation:AUTO:ACPR[:STATe] |
|
SOURce:MODulation:AUTO:ACPR:GBANd |
|
SOURce:MODulation:CORRection[:STATe] |
|
Zooms in on signal within a SA sweep. |
Mixer Setup commandsUsed for FCA, Swept IMDx, IMx Spectrum, NFx, and GCx applications. See the Mixer / Converter Setup topic |
|
Create or Change a Custom (Application) Measurement |
|
Create a custom measurement |
CALCulate:CUSTom:DEFine |
Change a custom measurement |
CALCulate:CUSTom:MODify |
Return handle to a converter object |
None |
Mixer Bottom Buttons and X-Axis display |
|
Load a mixer setup |
|
Save a mixer setup |
|
Apply mixer settings |
|
Discard Changes |
|
X-axis display |
Calculate Input and Output frequencies |
|
Input to swept or fixed |
|
Input start frequency |
|
Input stop frequency |
|
Input power level |
|
Input fixed frequency |
|
Set LO |
|
LO freq fixed or swept |
|
LO fixed frequency |
|
LO start frequency |
|
LO stop frequency |
|
Input Greater / Less that LO |
|
Set IF |
|
Sideband (high or low) |
|
IF start frequency |
|
IF stop frequency |
|
Set Output |
|
Sideband (high or low) |
|
Output start frequency |
|
Output stop frequency |
|
Output to swept or fixed |
|
Output fixed frequency |
LO power |
|
LO power start |
|
LO power stop |
|
Source Attenuator |
|
Receiver Attenuator |
SENSe:POWer:ATTenuator |
Leveling Mode |
|
Number of LOs (1 or 2) |
|
Recall a previously-configured external source. |
|
Assign a source to mixer input or LO. |
|
Read all assigned roles |
|
Read the source assigned to a role. |
|
Input Numerator Frac.Mult |
|
Input Denominator Frac.Mult |
|
LO Numerator Frac. Mult. |
|
LO Denominator Frac.Mult |
Setup and execution of TDR measurement Commands |
|
Sets the type of parameter and format allocation for each trace. |
|
Sets the DUT topology. |
|
Sets the emphasis post1 level. |
|
Sets the emphasis post2 level. |
|
Sets the emphasis pre1 level. |
|
Turns the emphasis function state ON or OFF. |
|
Sets the equalization CTLE DC gain parameter. |
|
Sets the equalization CTLE Pole1 parameter. |
|
Sets the equalization CTLE Pole2 parameter. |
|
Sets the equalization CTLE zero parameter. |
|
Sets the filename of the equalization equation user file. |
|
Turns the equalization function state ON or OFF. |
|
Sets the equalization type. |
|
Executes the calculation for the simulated eye diagram for the active trace. |
|
Sets the bits' power of 2 for a PRBS pattern. |
|
Sets the bit pattern type for the simulated eye function. |
|
Sets the bit rate in bits/sec for the simulated eye function. |
|
Sets the display limit value. |
|
Sets the periodic jitter frequency. |
|
Sets the periodic jitter magnitude in rms. |
|
Sets the random jitter magnitude in rms |
|
Turns the jitter function state with simulated eye ON or OFF. |
|
Sets the jitter function type for the simulated eye function. |
|
Sets the voltage level for bit "1" for the simulated eye function. |
|
Sets the rise time value for the simulated eye function. |
|
Sets the rise time threshold for the simulated eye. |
|
Sets the voltage level for bit "0" for the simulated eye function. |
|
Returns the mask test result. |
|
Turns the mask test function state with simulated eye ON or OFF. |
|
Returns the results of the eye measurement. |
|
Turns the overlay ON or OFF. |
|
Sets the rise time threshold level for the results of eye measurement. |
|
Turns the Eye/Mask window ON or OFF. |
|
Sets active marker number. |
|
Returns the delta time result value. |
|
Sets delta time reference position. |
|
Turns the delta time marker in the marker search ON or OFF. |
|
Sets the target trace number for the delta time function. |
|
Sets the trace format. |
|
Sets the measurement parameter. |
|
Sets state for the peeling function. |
|
Sets state for the smoothing function. |
|
Sets the impulse width value for the transform function. |
|
Sets rise time value for the transform function. |
|
Sets the rise time threshold level for the results of eye measurement. |
|
Sets the stimulus type for the transform function. |
|
Returns the rise time result value for marker search. |
|
Displays the rise time marker. |
|
Sets the rise time threshold for the rise time in the marker search function. |
|
Display TDR Commands |
|
Turns the continuous auto-scale mode for the eye y-axis ON or OFF. |
|
Sets the value of the y-axis scale per division for eye diagram. |
|
Sets the value of the eye diagram y-axis reference line. |
|
Sets the value of the eye diagram y-axis reference position. |
|
Changes the background color of the screen. |
|
Sets the display to off, data type, memory type, or data and memory type. |
|
Executes x-axis auto scaling. |
|
Sets the value of the x-axis scale per division. |
|
Sets the value of the x-axis reference line. |
|
Executes y-axis auto scaling. |
|
Sets the x-axis reference position for the time domain measurement. |
|
Selects the view point for waveform analysis either before or after the DUT. |
|
Sets or gets the minimize state. |
|
Memory TDR Commands |
|
Loads the specified user bit pattern file. |
|
Loads eye-mask file. |
|
Stores the user bit pattern file. |
|
Stores the eye-mask file. |
|
Correction TDR Commands |
|
Executes load measurement. |
|
Executes open measurement. |
|
Saves the result of the Loss Compensation sequence. |
|
Executes a thru measurement. |
|
Executes fixture compensation after ECAL. |
|
Executes full calibration using the ECal module. |
|
Sets the dielectric constant value. |
|
Executes deskew (auto port extension). |
|
Sets the standard for auto port extension. |
|
Sets the reference impedance value. |
|
Bandwidth, DUT information, avoid spurious function, and sweep TDR Commands |
|
Sets the IF bandwidth value. |
|
Executes auto DUT length setting. |
|
Sets the DUT length value. |
|
Executes avoid spurious. |
|
Queries the avoid spurious state. |
|
Sets the value of input bit rate for avoid spurious. |
|
Queries the Hot TDR mode status. |
|
Sets the TDR averaging trigger state on/off. |
|
Sets trigger mode. |
|
Executes single trigger. |
|
Enables/disables the Reduce IF BW at Low Frequencies feature in segments with IFBW arbitrary. |
|
Source Power Level TDR Command |
|
Sets the source power level. |
|
Preset TDR Command |
|
Executes a TDR preset. |
Sets and returns the noise bandwidth. |
SENSe:SA:BANDwidth:NOISe |
|
Enable or disable setting the noise bandwidth to its maximum possible value. |
SENSe:SA:BANDwidth:NOISe:AUTO |
|
Selects between a narrow and wide IF filter anti-aliasing path. |
SENSe:DISTortion:ADC:FILTer:TYPE |
|
This command launches the Receiver IF Cal. |
SENSe<cnum>:DISTortion:CORRection:COLLect:IF:ACQuire [SYNChronous | ASYNchronous] |
|
Identifies the normalization used for the EVM measurements. |
SENSe:DISTortion:EVM:NORMalize |
|
Sets and returns the frequency span window used for modeling the DUT's gain and distortion. |
SENSe:DISTortion:MEASure:CORRelation:APERture |
|
Enable or disable automatic calculation of the frequency span window used for modeling the DUT's gain and distortion. |
SENSe:DISTortion:MEASure:CORRelation:APERture:AUTO[:STATe] |
|
Sets and returns the integration bandwidth (IBW) of the lower ACP measurement. |
SENSe:DISTortion:MEASure:BAND:ACP:LOWer:IBW |
|
Sets and returns the lower ACP measurement offset. |
SENSe:DISTortion:MEASure:BAND:ACP:LOWer:OFFSet |
|
Sets and returns the integration bandwidth (IBW) of the upper ACP measurement. |
SENSe:DISTortion:MEASure:BAND:ACP:UPPer:IBW |
|
Sets and returns the upper ACP measurement offset. |
SENSe:DISTortion:MEASure:BAND:ACP:UPPer:OFFSet |
|
Adds a new distortion measurement band. |
SENSe:DISTortion:MEASure:BAND:ADD |
|
Automatically fills in the measurement settings for all bands from the currently active modulation file loaded in the source. |
SENSe:DISTortion:MEASure:BAND:AUTofill |
|
Sets and returns the carrier (Signal) integration bandwidth (IBW) for the distortion measurement. |
SENSe:DISTortion:MEASure:BAND:CARRier:IBW |
|
Sets and returns the carrier offset (Signal). |
SENSe:DISTortion:MEASure:BAND:CARRier:OFFSet |
|
Queries the total number of distortion measurement bands. |
SENSe:DISTortion:MEASure:BAND:COUNt? |
|
Deletes the specified distortion measurement band. |
SENSe:DISTortion:MEASure:BAND:DELete |
|
Deletes all existing bands and adds a single default band back into the Measurement Band Table. |
SENSe:DISTortion:MEASure:BAND:INITialize |
|
Assigns a name to the specified distortion measurement band. |
SENSe:DISTortion:MEASure:BAND:NAME |
|
Sets and returns the notch integration bandwidth (IBW) for an NPR Notch modulation measurement. |
SENSe:DISTortion:MEASure:BAND:NOTCh:IBW |
|
Sets and returns the notch offset for an NPR Notch modulation measurement. |
SENSe:DISTortion:MEASure:BAND:NOTCh:OFFSet |
|
Set and read the modulation distortion type. |
SENSe:DISTortion:MEASure:BAND:TYPE |
|
Sets the measurement filter to either None (default) or RRC (root-raised-cosine filter) |
SENSe:DISTortion:MEASure:FILTer |
|
Sets and returns the Alpha factor of the measurement filter. |
SENSe:DISTortion:MEASure:FILTer:ALPHa |
|
Sets and returns the Symbol Rate of the filter. |
SENSe:DISTortion:MEASure:FILTer:SRATe |
|
Enables or disables using the symbol rate from the file. |
SENSe:DISTortion:MEASure:FILTer:SRATe:AUTO[:STATe] |
|
Sets and returns the distortion modulation source name. |
SENSe:DISTortion:MODulate:SOURce |
|
Sets and returns the VNA port number connected to the DUT input. |
SENSe:DISTortion:PATH:DUT:INPut |
|
Sets and returns the nominal DUT gain. |
SENSe:DISTortion:PATH:DUT:NOMinal:GAIN |
|
Sets and returns the nominal DUT noise figure. |
SENSe:DISTortion:PATH:DUT:NOMinal:NF |
|
Include or exclude the NF nominal value. |
SENSe:DISTortion:PATH:DUT:NOMinal:NF:INCLude |
None |
Sets and returns the VNA port number connected to the DUT output. |
SENSe:DISTortion:PATH:DUT:OUTPut |
|
Enables or disables the external modulated source to pass through the attenuator of the specified PNA source |
SENSe:DISTortion:PATH:SOURce:ATTenuation:INCLude |
|
Sets and returns the nominal gain of an external source amplifier. |
SENSe:DISTortion:PATH:SOURce:NOMinal:AMPLifier |
|
Enables or disables receiver timing auto generation from the source pulse timing. |
SENSe:DISTortion:PULSe:RECeiver:AUTO |
|
Sets and returns the carrier center frequency. |
SENSe:DISTortion:SWEep:CARRier:FREQuency |
|
Selects between a ramp type power sweep or a list of power values to define a power sweep. |
SENSe:DISTortion:SWEep:POWer:CARRier:LEVel:TYPE |
|
Adds a new row to the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:ADD |
|
Deletes the specified row from the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:DELete |
|
Sets and returns the power level used for the specified row in the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:LEVel |
|
Specifies the file path to recall a previous power sweep list file. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:LOAD |
|
Sets and returns the noise bandwidth setting used for the specified row in the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:NBW |
|
Selects the noise bandwidth mode in the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:NBW:MODE |
|
Sets and returns the number of power points to measure for the power sweep list measurement. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:POINts |
|
Sets and returns the receiver attenuation for the specified row in the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:RECeiver:ATTenuation |
|
Selects the receiver attenuation mode in the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:RECeiver:ATTenuation:MODE |
|
Specifies the file path to save a power sweep list file. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:SAVE |
|
Sets and returns the source attenuation for the specified row in the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:SOURce:ATTenuation |
|
Selects the source attenuation mode in the power sweep list table. |
SENSe:DISTortion:SWEep:POWer:CARRier:LIST:SOURce:ATTenuation:MODE |
|
Sets and returns the starting power level for the power sweep ramp measurement. |
SENSe:DISTortion:SWEep:POWer:CARRier:RAMP:LEVel:STARt |
|
Sets and returns the stop power level for the power sweep ramp measurement. |
SENSe:DISTortion:SWEep:POWer:CARRier:RAMP:LEVel:STOP |
|
Enable or disable increasing noise bandwidth at high powers automatically for faster measurements. |
SENSe:DISTortion:SWEep:POWer:CARRier:RAMP:NBW:AUTO |
|
Sets and returns the number of power points to measure for the power sweep ramp measurement. |
SENSe:DISTortion:SWEep:POWer:CARRier:RAMP:POINts |
|
Enable or disable the re-use of the previous linear S-parameter measurements if available and skip sweep. |
SENSe:DISTortion:SWEep:SPARam:REUSe |
|
Enable or disable noise sweep used for the distortion test. |
SENSe:DISTortion:SWEep:NOISe |
|
Enables or disables S-parameter sweep. |
SENSe:DISTortion:SWEep:SPARam[:STATe] |
|
Sets and returns the power level used to measure the DUT gain when operating in its linear region. |
SENSe:DISTortion:SWEep:POWer:SPARam:LEVel |
|
Sets and returns the IF bandwidth for the linear S21 sweep. |
SENSe:DISTortion:SWEep:SPARam:BWIDth |
|
Sets and returns the step size for the linear S21 sweep. |
SENSe:DISTortion:SWEep:SPARam:STEP |
|
Selects between a chirp signal from the external signal generator or an internal CW signal in the VNA for measuring S-parameters. |
SENSe:DISTortion:SWEep:SPARam:TYPE |
|
Sets and returns the power level used for the distortion test at either the input or output of the DUT. |
SENSe:DISTortion:SWEep:POWer:CARRier:LEVel |
|
Set and read where to apply power to the DUT (input or output). |
SENSe:DISTortion:SWEep:POWer:CARRier:LEVel:PORT |
|
Keeps RF power ON at the End of Sweep. |
SENSe:DISTortion:SWEep:RETRace:POWer |
|
Sets and returns the delay in seconds before the test signal to allow the RF source to settle. |
SENSe:DISTortion:SWEep:DWELl |
|
Selects between a fixed or power sweep type of sweep. |
SENSe:DISTortion:SWEep:TYPE |
|
Specifies the file path to save a modulation distortion table file. |
SENSe:DISTortion:TABLe:DISPlay:SAVE |
|
Sort distortion table by band or power. |
SENSe:DISTortion:TABLe:DISPlay:SORT |
|
LO Feedthru Monitor Commands |
||
Return the last monitor result of LO feedthru monitor. |
|
|
Return the last monitor value of LO feedthru monitor. |
|
|
Set and read the target receiver for LO Feedthru monitor. |
|
|
Set and read the LO feedthru monitoring state. |
|
|
Set and read the threshold level for warning. |
|
|
Set and read the monitoring method for LO feedthru monitor. |
|
|
Calibrate Source Modulation Commands |
|
|
Set and read the ACP modulation calibration state. |
SOURce:MODulation:CORRection:COLLection:ACP:ENABle |
|
Sets and reads the maximum number of iterations for the lower ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:LOWer:ITERations |
|
Sets and reads the receiver for the lower ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:LOWer:RECeiver |
|
Sets and reads the calibration span for a lower ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:LOWer:SPAN |
|
Sets and reads the desired ACP calibration tolerance for the lower ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:LOWer:TOLerance |
|
Enables or disables the upper ACP (ACPUp) modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:UPPer:ENABle |
|
Sets and reads the maximum number of iterations for the upper ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:UPPer:ITERations |
|
Sets and reads the receiver for the upper ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:UPPer:RECeiver |
|
Sets and reads the calibration span for an upper ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:UPPer:SPAN |
|
Sets and reads the desired ACP calibration tolerance for the upper ACP modulation calibration. |
SOURce:MODulation:CORRection:COLLection:ACP:UPPer:TOLerance |
|
Setsand reads the ACP lower frequency delta from the edge of the carrier to the beginning of the Cal Span. |
SOURce:MODulation:CORRection:COLLection:ACP:LOWer:GBANd |
|
Sets and reads the ACP upper frequency delta from the edge of the carrier to the beginning of the calibration span. |
SOURce:MODulation:CORRection:COLLection:ACP:UPPer:GBANd |
|
Enable or disable the distortion calibration state. |
SOURce:MODulation:CORRection:COLLection:DISTortion:ENABle |
|
Sets and reads the maximum number of iterations used by the calibration routine. |
SOURce:MODulation:CORRection:COLLection:DISTortion:ITERations |
|
Sets and reads the receiver for distortion calibration. |
SOURce:MODulation:CORRection:COLLection:DISTortion:RECeiver |
|
Sets and reads the calibration span for a distortion calibration. |
SOURce:MODulation:CORRection:COLLection:DISTortion:SPAN |
|
Sets and reads the desired distortion calibration tolerance. |
SOURce:MODulation:CORRection:COLLection:DISTortion:TOLerance |
|
Enable or disable the equalization calibration state. |
SOURce:MODulation:CORRection:COLLection:EQUalization:ENABle |
|
Sets and reads the maximum number of iterations used by the calibration routine. |
SOURce:MODulation:CORRection:COLLection:EQUalization:ITERations |
|
Sets and reads the receiver for equalization calibration. |
SOURce:MODulation:CORRection:COLLection:EQUalization:RECeiver |
|
Sets and reads the calibration span for a equalization calibration. |
SOURce:MODulation:CORRection:COLLection:EQUalization:SPAN |
|
Sets and reads the desired equalization calibration tolerance. |
SOURce:MODulation:CORRection:COLLection:EQUalization:TOLerance |
|
Returns a list of the calibrations stored in the .mdx file. |
SOURce:MODulation:FILE:CORRection:CATalog? |
|
Deletes any of the calibration files stored in the .mdx file. |
SOURce:MODulation:FILE:CORRection:DELete? |
|
Returns the frequency of the specified source modulation calibration file. |
SOURce:MODulation:FILE:CORRection:FREQuency? |
|
Returns the power level of the specified source modulation calibration file. |
SOURce:MODulation:FILE:CORRection:POWer? |
|
Append source modulation calibration files stored in the .mdx file. |
SOURce:MODulation:CORRection:COLLection:APPend |
|
Sets and reads a fixed frequency. |
SOURce:MODulation:CORRection:COLLection:FREQuency[:FIXed] |
|
Sets and reads the number of frequency measurement points. |
SOURce:MODulation:CORRection:COLLection:FREQuency:POINts |
|
Sets and reads the start frequency to use for a swept frequency source modulation calibration. |
SOURce:MODulation:CORRection:COLLection:FREQuency:STARt |
|
Sets and reads the stop frequency to use for a swept frequency calibration. |
SOURce:MODulation:CORRection:COLLection:FREQuency:STOP |
|
Sets and reads the calibration frequency type to fixed or swept. |
SOURce:MODulation:CORRection:COLLection:FREQuency:TYPE |
|
Enable or disable the LO feedthru calibration state. |
SOURce:MODulation:CORRection:COLLection:LO:FTHRu:ENABle |
|
Sets and reads the maximum number of iterations used by the calibration routine. |
SOURce:MODulation:CORRection:COLLection:LO:FTHRu:ITERations |
|
Sets and reads the receiver for LO feedthru modulation calibration. |
SOURce:MODulation:CORRection:COLLection:LO:FTHRu:RECeiver |
|
Sets and reads the calibration span for a LO feedthru modulation calibration. |
SOURce:MODulation:CORRection:COLLection:LO:FTHRu:SPAN |
|
Sets and reads the desired LO feedthru modulation calibration tolerance. |
SOURce:MODulation:CORRection:COLLection:LO:FTHRu:TOLerance |
|
Sets and reads a fixed power level. |
SOURce:MODulation:CORRection:COLLection:POWer[:FIXed] |
|
Sets and reads the number of power measurement points. |
SOURce:MODulation:CORRection:COLLection:POWer:POINts |
|
Sets and reads the start power level to use for a swept calibration. |
SOURce:MODulation:CORRection:COLLection:POWer:STARt |
|
Sets and reads the stop power level to use for a swept calibration. |
SOURce:MODulation:CORRection:COLLection:POWer:STOP |
|
Sets and reads the calibration power type to fixed or swept. |
SOURce:MODulation:CORRection:COLLection:POWer:TYPE |
|
Create/Edit Modulation File |
||
Sets and reads the source sample rate. |
SOURce:MODulation:FILE:INITialize |
|
Specifies the file path to recall a previous modulation file. |
SOURce:MODulation:FILE:LOAD |
|
Sets and reads the source sample rate. |
SOURce:MODulation:FILE:SAVE |
|
Sets and reads the Carrier offset value. |
SOURce:MODulation:FILE:SIGNal:CARRier:OFFSet |
|
Sets and reads the number of compact modulation files to create. |
SOURce:MODulation:FILE:SIGNal:COMPact:FILE:NUMBer |
|
Sets and reads the compact modulation file selection. |
SOURce:MODulation:FILE:SIGNal:COMPact:FILE:NUMBer:SELect |
|
Specifies the file path to recall a previous modulation file from which to create a compact signal. |
SOURce:MODulation:FILE:SIGNal:COMPact:OFILe |
|
Returns the peak-to-average value of the original signal. |
SOURce:MODulation:FILE:SIGNal:COMPact:PAVG? |
|
Returns the peak-to-average value of the signal created from the original signal. |
SOURce:MODulation:FILE:SIGNal:COMPact:PAVG:CALCulated? |
|
Sets and reads the Peak-to-Avg priority for Compact signals. |
SOURce:MODulation:FILE:SIGNal:COMPact:PAVG:PRIority |
|
Allows setup of multiple carriers when defining a multicarrier signal. |
SOURce:MODulation:FILE:SIGNal:COMPact:SUBCarrier:NUMBer |
|
Sets and reads the offset of the selected subcarrier. |
SOURce:MODulation:FILE:SIGNal:COMPact:SUBCarrier:OFFSet |
|
Sets and reads the span of the selected subcarrier. |
SOURce:MODulation:FILE:SIGNal:COMPact:SUBCarrier:SPAN |
|
Sets and reads where to start the compact signal within the original signal. |
SOURce:MODulation:FILE:SIGNal:COMPact:TIME:STARt |
|
Returns the calculated start time of the signal created from the original signal. |
SOURce:MODulation:FILE:SIGNal:COMPact:TIME:STARt:CALCulated? |
|
Sets and reads the start time priority for Compact signals. |
SOURce:MODulation:FILE:SIGNal:COMPact:TIME:STARt:PRIority |
|
Sets and reads the DAC scale as a percentage of full scale. |
SOURce:MODulation:FILE:SIGNal:DAC:SCALing |
|
Sets the NPR notch location type for the selected NPR Notch modulation type. |
SOURce:MODulation:FILE:SIGNal:NPR:NOTCh:LOCation |
|
Sets and reads the number of NPR notches for NPR Notch modulation type. |
SOURce:MODulation:FILE:SIGNal:NPR:NOTCh:NUMBer |
|
Sets and reads the NPR notch offset frequency of the selected notch. |
SOURce:MODulation:FILE:SIGNal:NPR:NOTCh:OFFSet |
|
Sets and reads the span of the selected notch. |
SOURce:MODulation:FILE:SIGNal:NPR:NOTCh:SPAN |
|
Enables or disables signal optimization settings. |
SOURce:MODulation:FILE:SIGNal:OPTimize:ENABle |
|
Sets and reads the number of decimal digits limit for calculated frequencies. |
SOURce:MODulation:FILE:SIGNal:OPTimize:FREQuency:LIMit:DDIGits |
|
Enables or disables the number of decimal digits limit for calculated frequencies. |
SOURce:MODulation:FILE:SIGNal:OPTimize:FREQuency:LIMit:ENABle |
|
Sets and reads the frequency tolerance value (in percent). |
SOURce:MODulation:FILE:SIGNal:OPTimize:FREQuency:TOLerance |
|
Sets and reads the number of test signal harmonics you want to be protected against. |
SOURce:MODulation:FILE:SIGNal:OPTimize:HREJect |
|
Sets and reads the maximum distance between each tone. |
SOURce:MODulation:FILE:SIGNal:OPTimize:MAX:TONE:SPacing |
|
Sets and reads the minimum number of tones. |
SOURce:MODulation:FILE:SIGNal:OPTimize:MIN:TONE:NUMBer |
|
Sets and reads theminimum waveform period. |
SOURce:MODulation:FILE:SIGNal:OPTimize:MIN:WAVeform:PERiod |
|
Enables or disables the rejection of Nyquist frequencies. |
SOURce:MODulation:FILE:SIGNal:OPTimize:NYQReject:ENABle |
|
Sets the optimize signal type. |
SOURce:MODulation:FILE:SIGNal:OPTimize:TYPE |
|
Returns the calculated peak-to-average value. |
SOURce:MODulation:FILE:SIGNal:PAVG:CALCulated? |
|
Sets and reads the phase when Fixed phase is the Phase Type. |
SOURce:MODulation:FILE:SIGNal:PHASe:FIXed |
|
Sets and reads the phase seed when Random phase is the Phase Type. |
SOURce:MODulation:FILE:SIGNal:PHASe:RANDom:SEED |
|
Sets the phase type. |
SOURce:MODulation:FILE:SIGNal:PHASe:TYPE |
|
Sets and reads the signal span. |
SOURce:MODulation:FILE:SIGNal:SPAN |
|
Returns the calculated signal span. |
SOURce:MODulation:FILE:SIGNal:SPAN:CALCulated? |
|
Sets and reads the signal span priority. |
SOURce:MODulation:FILE:SIGNal:SPAN:PRIority |
|
Sets and reads the source sample rate. |
SOURce:MODulation:FILE:SIGNal:SRATe |
|
Returns the calculated sampling rate of the signal created from the original signal. |
SOURce:MODulation:FILE:SIGNal:SRATe:CALCulated? |
|
Set and read the auto sample rate. |
SOURce:MODulation:FILE:SIGNal:SRATe:AUTO |
|
Sets and reads the number of tones. |
SOURce:MODulation:FILE:SIGNal:TONE:NUMBer |
|
Returns the calculated number of tones. |
SOURce:MODulation:FILE:SIGNal:TONE:NUMBer:CALCulated? |
|
Sets and reads the tone number priority. |
SOURce:MODulation:FILE:SIGNal:TONE:NUMBer:PRIority |
|
Sets and reads the tone spacing. |
SOURce:MODulation:FILE:SIGNal:TONE:SPACing |
|
Returns the calculated spacing between the tones. |
SOURce:MODulation:FILE:SIGNal:TONE:SPACing:CALCulated? |
|
Sets and reads the tone spacing priority. |
SOURce:MODulation:FILE:SIGNal:TONE:SPACing:PRIority |
|
Returns the number of tones. |
SOURce:MODulation:FILE:TONE:NUMBer? |
|
Returns the tone frequency in Hz relative to the carrier. |
SOURce:MODulation:FILE:TONE:FREQuency? |
|
Sets and reads the power in dBm of the specified tone number. |
SOURce:MODulation:FILE:TONE:POWer |
|
Sets and reads the phase in degrees of the specified tone number. |
SOURce:MODulation:FILE:TONE:PHASe |
|
Set specified tone state to on or off. |
SOURce:MODulation:FILE:TONE[:STATe] |
|
Set all tone states to on or off. |
SOURce:MODulation:FILE:TONE:ALL[:STATe] |
|
Saves the specified multitone file. |
SOURce:MODulation:FILE:TONE:SAVE |
|
Loads the specified multitone file. |
SOURce:MODulation:FILE:TONE:LOAD |
|
Sets the modulation type. |
SOURce:MODulation:FILE:TYPE |
|
Distortion Table Commands |
||
Returns the currently displayed Distortion Table parameters. |
SENSe:DISTortion:TABLe:DISPlay:CATalog? |
|
Deletes the specified parameter from the Distortion Table. |
SENSe:DISTortion:TABLe:DISPlay:DELete |
|
Adds the specified parameter to the Distortion Table. |
SENSe:DISTortion:TABLe:DISPlay:FEED |
|
Returns a list of existing band names from the Measurement Band Table. |
SENSe:DISTortion:TABLe:CATalog? |
|
Returns a list of data parameter names corresponding to the currently specified Measurement Type. |
SENSe:DISTortion:TABLe:DATA:CATalog? |
|
Returns a list of data values from the Distortion Table for the specified band and parameter name. |
SENSe:DISTortion:TABLe:DATA:VALue? |
|
|
|
|
Modulation Distortion Marker Commands |
||
Set and read the SA marker function type. |
|
|
Sets and reads the integration bandwidth marker. |
|
|
Sets and reads the ACPR density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:ACPR[:STATe] CALCulate:SA:MARKer:BDENsity:ACPR[:STATe] |
|
Sets and reads the NPR density marker. |
CALCulate:MEASure:SA:MARKer:BDENsity:NPR[:STATe] CALCulate:SA:MARKer:BDENsity:NPR[:STATe] |
|
Executes the search ACPR density marker. |
|
|
Executes the search NPR density marker. |
|
|
|
|
|
Measurement Data |
||
Retrieves trace data (Y data) from the modulation distortion measurement. |
|
|
Retrieves frequency tone data from the modulation distortion measurement. |
|