Click here to view links to Setup commands for all Measurement Classes.
| Main Tab Commands | ||
| Softkey | Sub-item | SCPI |
| Sweep Setup... |
Sweep Type | |
| Linear Frequency | SENSe:SWEep:TYPE | |
| Log Frequency | SENSe:SWEep:TYPE | |
| Power Sweep | SENSe:SWEep:TYPE | |
| CW Time | SENSe:SWEep:TYPE | |
| Segment Sweep | SENSe:SWEep:TYPE | |
| Phase Sweep | SENSe:SWEep:TYPE | |
| Sweep Properties | ||
| Start | SENSe:FREQuency:STARt | |
| Stop | SENSe:FREQuency:STOP | |
| Power | SOURce:POWer[:LEVel][:IMMediate][:AMPLitude] | |
| Points | SENSe:SWEep:POINts | |
| IF Bandwidth | SENSe:BWIDth[:RESolution] | |
| Start Power | SOURce:POWer:STARt | |
| Stop Power | SOURce:POWer:STOP | |
| CW Freq | SENSe:FREQuency[:CW] | |
| Segment Table | ||
| X-axis Point Spacing | SENSe:SEGMent:X:SPACing | |
| Allow arbitrary Segments | SENSe:SEGMent:ARBitrary | |
| Display Center/Span Freq | SENSe:SEGMent:FREQuency:CENTer SENSe:SEGMent:FREQuency:SPAN |
|
| Timing | ||
| Sweep Time | SENSe:SWEep:TIME | |
| Dwell Time | SENSe:SWEep:DWELl | |
| Sweep Delay | SENSe:SWEep:DWELl:SDELay | |
| Auto Sweep Time | SENSe:SWEep:TIME:AUTO | |
| Fast Sweep - Reduce settling time | SENSe:SWEep:SPEed | |
| Sweep Mode | SENSe:SWEep:GENeration | |
| Sweep Sequence | SENSe:SWEep:GENeration:POINtsweep | |
|
Meas Class... |
CALCulate:MEASure:DEFine | |
| Quick Start... | S-Param | CALCulate:MEASure:PARameter |
| Balanced | CALCulate:MEASure:PARameter | |
| Other | CALCulate:MEASure:PARameter | |
| Layout Tab Commands | ||
| Softkey | Sub-item | SCPI |
| New Trace | DISPlay:WINDow:TRACe[:STATe] | |
| New Channel | None | |
| New Window | DISPlay:WINDow[:STATe] | |
| New Sheet | DISPlay:SHEet:STATe | |
| Delete | TrN | DISPlay:WINDow:TRACe:DELete |
| ChN | SYSTem:CHANnels:DELete | |
| WinN | DISPlay:WINDow[:STATe] | |
| Select | TrN | DISPlay:WINDow:TRACe:SELect |
| ChN | None | |
| WinN | DISPlay:WINDow:TRACe:SELect | |
| Measure... | S-Parameter | CALCulate:MEASure:PARameter |
| Balanced | CALCulate:MEASure:PARameter | |
| Receivers | CALCulate:MEASure:PARameter | |
| Meas Class... | CALCulate:MEASure:DEFine | |
| Internal Hardware Tab Commands | ||
| Softkey | Sub-item | SCPI |
|
Interface Control... |
Enable Interface Control |
|
|
Channel |
None |
|
|
Channel Control Label |
None |
|
|
Before Sweep Start |
||
|
Enable Control |
None |
|
|
Handler I/O Control |
||
|
Test Set I/O Control (addr. data) |
||
|
Dwell After Command |
None |
|
|
Aux I/O Output Voltage |
||
|
After Sweep End |
||
|
Enable Control |
None |
|
|
Handler I/O Control |
||
|
Test Set I/O Control (addr. data) |
||
|
Dwell After Command |
None |
|
|
Aux I/O Output Voltage |
||
|
Reset All |
||
|
Save |
None |
|
|
Recall |
||
|
Softkey |
Sub-item |
SCPI |
|
External Device... |
New |
|
|
Remove |
||
|
Name |
||
|
Device Type |
||
|
Driver |
||
|
Active - Show in UI |
||
|
DC Meter |
||
|
Timeout |
None |
|
|
Dwell Before Sweep |
||
|
Dwell After Point Set |
||
|
Type |
||
|
Receiver Correction On |
||
|
Offset |
||
|
Scaling |
||
|
|
||
|
ID Query |
||
|
Error Query |
||
|
Enable I/O |
||
|
Disable I/O |
||
|
Before Sweep |
||
|
After Sweep |
||
|
Abort Sweep |
||
|
Point Set Commands |
||
|
DC Source |
||
|
Timeout |
None |
|
|
Dwell Before Sweep |
||
|
Dwell After Point Set |
||
|
Type |
||
|
|
||
|
|
||
|
|
||
|
ID Query |
||
|
Error Query |
||
|
Enable I/O |
||
|
Disable I/O |
||
|
Read Max Using |
||
|
Define Max As |
||
|
Read Min Using |
||
|
Define Min As |
||
|
Before Sweep |
||
|
After Sweep |
||
|
Abort Sweep |
||
|
Point Set Commands |
||
|
Power Meter |
||
|
Sensor A/B |
None |
|
|
Tolerance |
||
|
Max Number of Readings |
||
|
Use Loss Table |
||
|
Edit Table |
SOURce:POWer:CORRection:COLLect:TABLe:POINts? |
|
|
Pulse Generator |
||
|
Time out |
||
|
Master Mode |
||
|
Output |
||
|
High |
||
|
Low |
||
|
Source Imp |
||
|
Load Imp |
||
|
SMU |
||
|
Setup |
|
|
|
Chan N |
||
|
Trigger Mode |
||
|
SMU Trigger In |
|
|
|
SMU Trigger Out |
|
|
|
Source/Voltage Meter/Current Meter |
|
|
|
SMU Chan |
||
|
Source type |
||
|
Timeout |
||
|
Dwell Before Sweep |
||
|
Dwell After Point Set |
||
|
Current Limit |
||
|
Voltage Limit |
||
|
Source Correction On |
||
|
Offset |
||
|
Scaling |
||
|
Receiver Correction On |
||
|
Offset |
||
|
Scaling |
||
|
|
||
|
|
||
|
Source |
||
|
Timeout |
||
|
Dwell Per Point |
||
|
Enable Modulation Control |
||
|
Trigger Mode |
||
|
Trigger Port |
||
|
Edit Commands |
|
|
|
Operation complete (*OPC) |
None |
|
|
Preset |
None |
|
|
Set CW Frequency |
None |
|
|
Set CW Sweep Mode |
None |
|
|
Set Power |
None |
|
|
Set Power State |
None |
|
|
Power Meter Setup... |
Interface |
None |
|
Sensors |
||
|
Tolerance |
||
|
Max Number of Readings |
||
|
Use Loss Table |
||
|
Edit Table |
||
|
Select ID |
||
|
Test Set |
||
|
Enable Test Set Control |
None |
|
|
Show Test Set Properties |
None |
|
|
Port Control |
||
|
Control Lines |
||
|
Line X |
None |
|
|
DC Source |
||
|
(E5092A only) |
||