Click here to view links to Setup commands for all Measurement Classes.
Main Tab Commands | ||
Softkey | Sub-item | SCPI |
Sweep Setup... |
Sweep Type | |
Linear Frequency | SENSe:SWEep:TYPE | |
Log Frequency | SENSe:SWEep:TYPE | |
Power Sweep | SENSe:SWEep:TYPE | |
CW Time | SENSe:SWEep:TYPE | |
Segment Sweep | SENSe:SWEep:TYPE | |
Phase Sweep | SENSe:SWEep:TYPE | |
Sweep Properties | ||
Start | SENSe:FREQuency:STARt | |
Stop | SENSe:FREQuency:STOP | |
Power | SOURce:POWer[:LEVel][:IMMediate][:AMPLitude] | |
Points | SENSe:SWEep:POINts | |
IF Bandwidth | SENSe:BWIDth[:RESolution] | |
Start Power | SOURce:POWer:STARt | |
Stop Power | SOURce:POWer:STOP | |
CW Freq | SENSe:FREQuency[:CW] | |
Segment Table | ||
X-axis Point Spacing | SENSe:SEGMent:X:SPACing | |
Allow arbitrary Segments | SENSe:SEGMent:ARBitrary | |
Display Center/Span Freq | SENSe:SEGMent:FREQuency:CENTer SENSe:SEGMent:FREQuency:SPAN |
|
Timing | ||
Sweep Time | SENSe:SWEep:TIME | |
Dwell Time | SENSe:SWEep:DWELl | |
Sweep Delay | SENSe:SWEep:DWELl:SDELay | |
Auto Sweep Time | SENSe:SWEep:TIME:AUTO | |
Fast Sweep - Reduce settling time | SENSe:SWEep:SPEed | |
Sweep Mode | SENSe:SWEep:GENeration | |
Sweep Sequence | SENSe:SWEep:GENeration:POINtsweep | |
Meas Class... |
CALCulate:MEASure:DEFine | |
Quick Start... | S-Param | CALCulate:MEASure:PARameter |
Balanced | CALCulate:MEASure:PARameter | |
Other | CALCulate:MEASure:PARameter | |
Layout Tab Commands | ||
Softkey | Sub-item | SCPI |
New Trace | DISPlay:WINDow:TRACe[:STATe] | |
New Channel | None | |
New Window | DISPlay:WINDow[:STATe] | |
New Sheet | DISPlay:SHEet:STATe | |
Delete | TrN | DISPlay:WINDow:TRACe:DELete |
ChN | SYSTem:CHANnels:DELete | |
WinN | DISPlay:WINDow[:STATe] | |
Select | TrN | DISPlay:WINDow:TRACe:SELect |
ChN | None | |
WinN | DISPlay:WINDow:TRACe:SELect | |
Measure... | S-Parameter | CALCulate:MEASure:PARameter |
Balanced | CALCulate:MEASure:PARameter | |
Receivers | CALCulate:MEASure:PARameter | |
Meas Class... | CALCulate:MEASure:DEFine | |
Internal Hardware Tab Commands | ||
Softkey | Sub-item | SCPI |
Interface Control... |
Enable Interface Control |
|
Channel |
None |
|
Channel Control Label |
None |
|
Before Sweep Start |
||
Enable Control |
None |
|
Handler I/O Control |
||
Test Set I/O Control (addr. data) |
||
Dwell After Command |
None |
|
Aux I/O Output Voltage |
||
After Sweep End |
||
Enable Control |
None |
|
Handler I/O Control |
||
Test Set I/O Control (addr. data) |
||
Dwell After Command |
None |
|
Aux I/O Output Voltage |
||
Reset All |
||
Save |
None |
|
Recall |
||
Softkey |
Sub-item |
SCPI |
External Device... |
New |
|
Remove |
||
Name |
||
Device Type |
||
Driver |
||
Active - Show in UI |
||
DC Meter |
||
Timeout |
None |
|
Dwell Before Sweep |
||
Dwell After Point Set |
||
Type |
||
Receiver Correction On |
||
Offset |
||
Scaling |
||
|
||
ID Query |
||
Error Query |
||
Enable I/O |
||
Disable I/O |
||
Before Sweep |
||
After Sweep |
||
Abort Sweep |
||
Point Set Commands |
||
DC Source |
||
Timeout |
None |
|
Dwell Before Sweep |
||
Dwell After Point Set |
||
Type |
||
|
||
|
||
|
||
ID Query |
||
Error Query |
||
Enable I/O |
||
Disable I/O |
||
Read Max Using |
||
Define Max As |
||
Read Min Using |
||
Define Min As |
||
Before Sweep |
||
After Sweep |
||
Abort Sweep |
||
Point Set Commands |
||
Power Meter |
||
Sensor A/B |
None |
|
Tolerance |
||
Max Number of Readings |
||
Use Loss Table |
||
Edit Table |
SOURce:POWer:CORRection:COLLect:TABLe:POINts? |
|
Pulse Generator |
||
Time out |
||
Master Mode |
||
Output |
||
High |
||
Low |
||
Source Imp |
||
Load Imp |
||
SMU |
||
Setup |
|
|
Chan N |
||
Trigger Mode |
||
SMU Trigger In |
|
|
SMU Trigger Out |
|
|
Source/Voltage Meter/Current Meter |
|
|
SMU Chan |
||
Source type |
||
Timeout |
||
Dwell Before Sweep |
||
Dwell After Point Set |
||
Current Limit |
||
Voltage Limit |
||
Source Correction On |
||
Offset |
||
Scaling |
||
Receiver Correction On |
||
Offset |
||
Scaling |
||
|
||
|
||
Source |
||
Timeout |
||
Dwell Per Point |
||
Enable Modulation Control |
||
Trigger Mode |
||
Trigger Port |
||
Edit Commands |
|
|
Operation complete (*OPC) |
None |
|
Preset |
None |
|
Set CW Frequency |
None |
|
Set CW Sweep Mode |
None |
|
Set Power |
None |
|
Set Power State |
None |
|
Power Meter Setup... |
Interface |
None |
Sensors |
||
Tolerance |
||
Max Number of Readings |
||
Use Loss Table |
||
Edit Table |
||
Select ID |
||
Test Set |
||
Enable Test Set Control |
None |
|
Show Test Set Properties |
None |
|
Port Control |
||
Control Lines |
||
Line X |
None |
|
DC Source |
||
(E5092A only) |