Power Commands - Standard Measurement Class

Click here to view links to Power commands for all Measurement Classes.

Main

Port Power

Leveling
& Offsets

Attenuators

Main Tab Commands
Softkey Sub-item SCPI

COM

Power Level   SOURce:POWer[:LEVel][:IMMediate][:AMPLitude] DISPlay:GUI:POWer:SPIN:RESolution

TestPortPower

PowerSpinResolution

RF Power ON/OFF OUTPut[:STATe]

SourcePortMode

Start Power   SOURce:POWer:PORT:STARt

StartPower

Stop Power   SOURce:POWer:PORT:STOP

StopPower

Power and Attenuators... Power ON (All Channels) None

None

Port Powers Coupled SOURce:POWer:COUPle

CouplePorts

Name SOURce:POWer:MODE

SourcePortMode

State SOURce:POWer:MODE

SourcePortMode

Port Power SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]

TestPortPower

Start Power SOURce:POWer:PORT:STARt

StartPower

Stop Power SOURce:POWer:PORT:STOP

StopPower

Leveling Mode SOURce:POWer:ALC[:MODE]

ALCLevelingMode

Channel Power Slope SOURce:POWer[:LEVel]:SLOPe:STATe SOURce:POWer[:LEVel]:SLOPe

PowerSlopeState

PowerSlope

Offsets and Limits...
    Power Limit - State SYSTem:POWer:LIMit:STATe

State

    Power Limit - Limit SYSTem:POWer:LIMit

Limit

    Source Power SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]

TestPortPower

    Power Offset SOURce:POWer:ALC[:MODE]:RECeiver:OFFSet

PowerOffset

    Port Power SOURce:POWer:PORT:STARt SOURce:POWer:PORT:STOP

StartPower

StopPower

Receiver Leveling... (VNAs with Pre-Sweep Mode, Point Mode, and Prior Sweep Mode)

    Controlled Source

SOURce:POWer:ALC[:MODE]:RECeiver:REFerence

ReferenceReceiver

    Enable Leveling

SOURce:POWer:ALC[:MODE]:RECeiver

State

    Leveling Receiver

SOURce:POWer:ALC[:MODE]:RECeiver:REFerence

ReferenceReceiver

    Leveling Type

SOURce:POWer:ALC[:MODE]:RECeiver:ACQuisition:MODE

None

    Max Power

SOURce:POWer:ALC[:MODE]:RECeiver:SAFE:MAX

PowerMax

    Min Power

SOURce:POWer:ALC[:MODE]:RECeiver:SAFE:MIN

PowerMin

    Enable Safe Mode Leveling Using Max Step Size

SOURce:POWer:ALC[:MODE]:RECeiver:SAFE

SafeMode

        Max step size

SOURce:POWer:ALC[:MODE]:RECeiver:SAFE:STEP

PowerStep

    Update Source Power Calibration with Leveling Data

SOURce:POWer:ALC[:MODE]:RECeiver:LSPC

LastLevelingAsSPC

    Source ALC Hardware

SOURce:POWer:ALC[:MODE]

ALCLevelingMode

    Leveling Tolerance

SOURce:POWer:ALC[:MODE]:RECeiver:TOLerance

Tolerance

    Leveling Max Iterations

SOURce:POWer:ALC[:MODE]:RECeiver:ITERation:VALue

SOURce:POWer:ALC[:MODE]:RECeiver:ITERation:ENABle

IterationNumber

None

    Leveling Receiver Frequency

SOURce:POWer:ALC[:MODE]:RECeiver:FTYPe

FrequencyType

    Leveling IFBW

SOURce:POWer:ALC[:MODE]:RECeiver:FAST

SOURce:POWer:ALC[:MODE]:RECeiver:IFBW

LevelingIFBW

Path Configuration... SENSe:PATH:CONFig:ELEMent[:STATe]

Element

Port Power Tab Commands
Softkey Sub-item SCPI

COM

Select Port 1

None

None

Port 2

None

None

Port 3

None

None

Port 4

None

None

Port 1 Src2

None

None

Source3

None

None

Power Level   SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]

TestPortPower

Start Power   SOURce:POWer:PORT:STARt

StartPower

Stop Power   SOURce:POWer:PORT:STOP

StopPower

Source State AUTO SOURce:POWer:MODE

SourcePortMode

ON SOURce:POWer:MODE

SourcePortMode

OFF SOURce:POWer:MODE

SourcePortMode

Coupling ON SOURce:POWer:COUPle

CouplePorts

OFF SOURce:POWer:COUPle

CouplePorts

Leveling & Offsets Tab Commands
Softkey Sub-item SCPI

COM

Select Port 1

None

None

Port 2

None

None

Port 3

None

None

Port 4

None

None

Port 1 Src2

None

None

Source3

None

None

Slope ON/OFF SOURce:POWer[:LEVel]:SLOPe:STATe

PowerSlopeState

Power Slope SOURce:POWer[:LEVel]:SLOPe

PowerSlope

Offset   SOURce:POWer:CORRection:OFFSet:MAGNitude

PowerOffset

Limit ON/OFF SYSTem:POWer:LIMit:STATe

State

Power Limit SYSTem:POWer:LIMit

Limit

Offsets and Limits... Limit Source Pwr - State SYSTem:POWer:LIMit:STATe

State

Limit Source Pwr- Limit Always SYSTem:POWer:LIMit

Limit

Banded Power- Read Band Count  SYSTem:POWer:LIMit:BANDed:COMPuted:BAND:COUNt? None
Banded Power- Read start frequency SYSTem:POWer:LIMit:BANDed:COMPuted:BAND:FREQuency:STARt?  None
Banded Power- Read stop frequency SYSTem:POWer:LIMit:BANDed:COMPuted:BAND:FREQuency:STOP?  None
Banded Power- Read the power limit value 

SYSTem:POWer:LIMit:BANDed:COMPuted:BAND<bandnum>:VALue?

SYSTem:POWer:LIMit:BANDed:COMPuted:BAND:VALue? <frequency>

None
Banded Power- band definations  SYSTem:POWer:LIMit:BANDed:CONFigure  None
Banded Power- Reset SYSTem:POWer:LIMit:BANDed:RESet  None
Banded Power - State SYSTem:POWer:LIMit:BANDed:STATe  None
Limit Source Pwr - Limit During Cal SYSTem:POWer:LIMit:CALibration None
Source Power SOURce:POWer[:LEVel][:IMMediate][:AMPLitude]

TestPortPower

Power Offset SOURce:POWer:ALC[:MODE]:RECeiver:OFFSet

PowerOffset

Port Power SOURce:POWer:PORT:STARt SOURce:POWer:PORT:STOP

StartPower

StopPower

ALC Hardware

Internal

SOURce:POWer:ALC[:MODE]

ALCLevelingMode

Open Loop

SOURce:POWer:ALC[:MODE]

ALCLevelingMode

Receiver Leveling...

 

 

 

Attenuators Tab Commands
Softkey Sub-item SCPI

COM

Source Port 1

  SOURce:POWer1:ATTenuation

Attenuator

Source Port 2

  SOURce:POWer2:ATTenuation

Attenuator

Source Port 3

  SOURce:POWer3:ATTenuation

Attenuator

Source Port 4

  SOURce:POWer4:ATTenuation

Attenuator

Receiver A

  SENSe:POWer:ATTenuation

ReceiverAttenuator

Receiver B

  SENSe:POWer:ATTenuation

ReceiverAttenuator

Receiver C

  SENSe:POWer:ATTenuation

ReceiverAttenuator

Receiver D

  SENSe:POWer:ATTenuation

ReceiverAttenuator