The following are new or modified programming commands for the PLTS 2025 Update 1.0 release. See What's New.
Reset all settings for data integrity check. |
|
Set or get the tolerance for reciprocity or causality. |
|
Turn on or off data integrity enforcement for the specified type. |
|
Get or set the output file type of data integrity enforcement. |
|
Get the result of data integrity check. |
|
Apply data integrity enforcement. |
Connect PLTS to the hardware by VISA Address. |
The following are new or modified programming commands for the PLTS 2024 Update 1.0 release. See What's New.
Applies advanced algorithm to fixture impedance mismatching cases for better results. |
The following are new or modified programming commands for the PLTS 2024 release. See What's New.
Modified command to include FDUT. |
|
Reads the calculated length of specified fixture. |
|
Reads the calculated impedance of specified fixture. |
|
Turns on or off the option "Automatically iterate when Calibration Reference Z0 is set to System Z0 or custom value." |
|
Save the current AFR settings to an .xml file. |
|
Load AFR settings from an .xml file. |
The following are new or modified programming commands for the PLTS 2023 release. See What's New.
Initializes the multi-channel configuration. |
|
Sets or gets the name of multi-channel configuration. |
|
Sets the port count in the multi-channel eye configuration. |
|
Sets the description of the DUT configuration in multi-channel eye simulation. |
|
Sets the differential port mapping of the DUT configuration in multi-channel eye simulation. |
|
Sets the single-ended port mapping of the DUT configuration in multi-channel eye simulation. |
|
Sets the state of RX. |
|
Sets the port number of RX. |
|
Sets whether the RX port is single-ended or not. |
|
Sets the state of TX. |
|
Sets the length of the digital pattern of TX. |
|
Sets the pattern loop count of TX. |
|
Sets the bit pattern name. |
|
Sets the rise time of TX in ps. |
|
Sets the high level of the single-ended amplitude. |
|
Sets the low level of the single-ended amplitude. |
|
Sets the oversampling factor. |
|
Sets symbol rate of TX bit pattern in Gbps. |
|
Sets the port number of TX. |
|
Sets whether the TX port is single-ended or not. |
|
Sets or gets the multi-channel type. |
|
Adds a new crosstalk component. |
|
Sets whether the settings of XTalk channel is copied from XT channel. |
|
Sets the length of the digital pattern of XT. |
|
Sets the digital pattern name of the crosstalk component. |
|
Sets the phase relative to TX in degree. |
|
Sets the rise time of XT in ps. |
|
Sets the high level of the single-ended amplitude. |
|
Sets the low level of the single-ended amplitude. |
|
Sets the oversampling factor. |
|
Sets symbol rate of XTalk bit pattern. |
|
Sets the port number of XT. |
|
Sets whether the XT port is single-ended or not. |
Plot Commands |
|
Draws an enhanced eye plot in the specified view. |
The following are new or modified programming commands for the PLTS 2022 release. See What's New.
Sets or gets the DUT Gate Coefficient. |
|
Sets or gets the description of the AFR DUT Gate Domain (single-ended or differential). |
|
Turns ON or OFF the Fitting Thru after AFR DUT Gate. |
|
Turns ON or OFF the AFR DUT Gate. |
|
Turns ON or OFF the AFR DUT Gate Only Reflection option. |
|
Gets the AFR Version. |
Plot Commands |
|
(Added the query option.) Sets or gets the plot scale with x and y range. |
|
(Added the query option.) Sets the y-axis scale of a plot. |
|
(Added the query option.) Sets the y-axis scale of a plot. |
Gets the calset catalog in the connected instrument. |
|
Gets the date of the specified calset. |
|
Gets the time of the specified calset. |
Sets or gets the user preference to calculate and show the one-way time/distance for reflection parameters. |
The following are new or modified programming commands for the PLTS 2021 release. See What's New.
Turns ON of OFF AFR mode conversion. |
|
Resets AFR configuration. |
|
Gets or sets the manual start time in AFR configuration. |
|
Gets or sets the manual stop time in AFR configuration. |
|
Sets or gets the manual window coefficient type in AFR configuration. |
|
Turns ON or OFF the manual window coefficient of AFR. |
|
Applies or will undo AFR correction for the selected file. |
|
Selects the number of fixtures to be characterized. |
|
Sets "System Z0" to Calibration Reference Z0. |
|
Specifies whether thrus are used in case of multi-port fixtures. |
|
Selects the Auto impedance method and measures the fixture impedances. |
|
Loads the calibration standards data from a file. |
|
Measures calibration standard. |
|
Chooses the calibration standards. |
Adds a port group for the Fext. |
|
Clears the Fext port group. |
|
Sets or gets the Channel Operating Margin Configuration file. |
|
Adds a port group for the Next. |
|
Clears the Next port group. |
|
Sets or gets the Channel Operating Margin Thru ports. |
|
Sets or gets the Channel Operating Margin Standard Version. |
|
Runs the Channel Operating Margin. |
Saves the eye measurement data of all plots in a view to a .txt file. |
|
Saves the limit test results of all plots in a view to a .txt file. |
|
This command refreshes all traces in a plot. |
|
Resets the scale of all plots in the same view. |
|
Sets the x-axis scale of a plot. |
|
Sets the y-axis scale of a plot. |
|
Gets the index of the active trace in a plot. |
|
This command sets the display type of the X axis to linear or logarithmic. |
|
This command sets the display type of the Y axis to linear or logarithmic. |
|
Resets the scale of all plots in the same view. |
|
Saves the time-domain measurement data of all plots in a view to a .txt file. |
Resets balanced port impedance settings. |
|
Apply or undo balanced port impedance conversion. |
|
Sets or gets the imaginary part of the common-mode port impedance. |
|
Sets or gets the real part of the common-mode port impedance. |
|
Sets or gets the imaginary part of the differential port impedance. |
|
Sets or gets the real part of the differential port impedance. |
|
Sets or gets the rotation distance. |
Sets the user preference for step rise time options. |
Sets or gets the time domain DC point extrapolation method. |
|
Sets or gets the DC input resistance of a reflection parameter. |
|
Sets or gets the DC input value of a reflection parameter. |
|
Sets or gets the time domain filter mode for exponential window. |
|
Sets or gets the time domain window mode. |
The following are new or modified programming commands for the PLTS 2020 release. See What's New.
Sets the type of PAM4 eye measurement. |
|
Gets the PAM4 eye measurement result. |
Specifies whether the port impedances are normalized in saving AFR fixture files. |
Select parameters to export when the export file is a text file. |
|
Specifies whether the existing port configuration is used in the export. |
Sets the plot display format. |
|
Maximizes the specified plot or restores it to the original state. |
|
Saves the trace data of all traces in the plot to a .csv file. |
Loads a DUT configuration file to set the port map of the file to import. |
|
Saves the DUT configuration in the import to a .dcf file. |
Loads a DUT configuration file to set port mapping in the measurement. |
|
Saves the DUT configuration in the measurement to a .dcf file. |
The following are new or modified programming commands for the PLTS 2018 release. See What's New.
Adds a new annotation to the specified plot. |
|
Deletes an annotation from the specified plot. |
|
Sets or gets the relative position of annotation to the left of the plot canvas. |
|
Sets or gets the relative position of annotation to the top of the plot canvas. |
Initializes the delay measurement settings. |
|
Gets the maximum limit value of the delay measurement. |
|
Gets the minimum limit value of the delay measurement. |
|
Sets the reference type for the delay measurement. |
|
Sets the reference value for delay measurement. |
|
Sets the trace name for the delay measurement. |
|
Sets the type of delay measurement. |
DUT Configuration Commands - Configures a DUT file. |
|
Gets the number of ports of the DUT file. |
|
Gets the port map description of the DUT file. |
|
Gets the differential port map of the DUT file. |
|
Gets the single-ended port map of the DUT file. |
Embedding Commands - Embed fixture file on specified port. |
|
Sets or gets the fixture file to embed on the specified port. |
|
Sets initialize embedding. |
|
Reverse the embedding file on the left. |
|
Reverse the embedding file on the right. |
|
Turns embedding on or off. |
Excess Reactance Measurement Commands - Enable/disable and get excess reactance. |
|
Gets the measured excess reactance value of the specified trace. |
|
Turns on or off the measurement of excess reactance of the specified trace. |
Enables/disables exporting smoothed data. |
|
Specifies the data domain to export. |
|
Specifies the data format to export. |
|
Sets or gets the name of the user-defined equation to export. |
|
Sets or gets port mapping description. |
|
Sets or gets differential port mapping string. |
|
Loads a DUT configuration file to set the port map of the file to export. |
|
Exports the DUT configuration to a .dcf file. |
|
Sets or gets single-ended port mapping string. |
|
Selects data to export. |
|
Specifies the file type. |
File Merge Commands - Merge data files to make one Touchstone, Text, or Citifile. |
|
Merges two data files with different frequency ranges to create one Touchstone, Text, or Citifile. |
|
Sets the data format for the merged output file. |
|
Reset the file merge settings. |
|
Sets the data range for merged output file. |
|
Sets the number of frequency points for the merged output file. |
|
Sets the start frequency for the merged output file. |
|
Sets the stop frequency for the merged output file. |
|
Sets the file type for the merged output file. |
Impedance Commands - Various commands for setting impedance. |
|
Turns on or off the correcting impedance profile feature. |
|
Sets or gets common mode impedance. |
|
Enables or disables arbitrary mixed mode impedance conversion. |
|
Sets or gets differential impedance. |
Legend Commands - Adds legends to traces on specified plot. |
|
Adds legends for all traces on the specified plot. |
|
Deletes legends on the specified plot. |
|
Sets or gets the legend on the plot for the specified file. |
|
Sets or gets the legend type for the specified plot. |
|
Add legend for the specified trace to the plot. |
|
Delete legend for the specified trace on the plot. |
Initializes the rise time measurement settings. |
|
Gets the rise time limit value. |
|
Sets the trace name for the rise time measurement. |
|
Sets the type of rise time measurement. |
Sets or gets the highest extracted frequency in MHz for RLCG view. |
|
Sets or gets the physical length in m for RLCG view. |
Template and Report Commands - Import and export templates, catalog available templates, remove a specific template and create a report. |
|
Saves the template view with a new name. |
Velocity Factor Commands - Commands for setting velocity factor. |
|
Set or get the velocity factor. |