Get and Put Data:  Measurement | Cal | Power Cal | Custom
Other:
 GPIB Pass-through | VISA Pass-through | Capabilities | Status/Events | Rear-panel | FIFO and FastCW | Speed up Measurements!

Description

SCPI

COM

Get X-Axis values (variant)

SENS:X:VAL

Get X-axis Values

Get X-Axis values (typed)

N/A

Get X-Axis Values 2

Get X-axis for trace

Calc:X?

N/A

Get X-Axis values (Meas object)

N/A

Get XAxisValues

Get Measurement Data FROM the Analyzer

Get typed complex data from the specified location.

Returned in two arrays.

 

IArrayTrans.getComplex

Get typed NAComplex data from the specified location.

Returned in one array.

 

IArrayTrans.getNAComplex

Get typed data pairs from the specified location.

Returned in two arrays.

 

IArrayTrans.getPairedData

Get typed scalar data from the specified location.

Returned in one array.

 

IArrayTrans.getScalar

Get variant data from the specified location in a SPECIFIED FORMAT.

Returned in one array.

 

meas.GetDataByString

Get receiver data

Calc:RDATA?

All of the above

Specifies ASCII or REAL type for data transfers

Format:Data

N/A

Get complex or formatted data from the measurement or memory result buffer

Calc:Data

All of the above

Gets SnP data for the specified ports.

CALC:DATA:SNP:PORTs?

GetSnpDataWithSpecifiedPorts

Get ALL SnP data

Calc:Data:SnP

meas.GetSnPData

Put Measurement Data INTO the Analyzer

Put complex data into the specified location.

 

IArrayTrans.putComplex

Put typed NAComplex data into the specified location.

 

IArrayTrans.putNAComplex

Put scalar data into the measurement result location.

 

IArrayTrans.putScalar

Put complex Variant data into the specified location.

 

IArrayTrans.putDataComplex

Put complex or formatted data into the measurement or memory result buffer

Calc:Data

 

Get Calibration Data FROM the Analyzer

Get complex Error Term data

 

Get ErrorTermComplexByString

Get variant Error Term data

SENS:CORR:CSET:DATA

CSET:ETERm[:DATA]?

GetErrorTermByString

Get variant Error Term data by text filter

CSET:ETERm:CATalog?

Get ErrorTermList2

Get complex Standard data

 

GetStandardComplexByString

Get variant Standard data

 

GetStandardByString

Get variant Standard data by text filter

 

Get StandardList2

Put Calibration Data INTO the Analyzer

Put complex Error Term data

 

PutErrorTermComplexByString

Put variant Error Term data

SENS:CORR:CSET:DATA

CSET:ETERm[:DATA]

PutErrorTermByString

Put complex Standard data

 

PutStandardComplexByString

Put variant Standard  data

 

PutStandardByString

Power Calibration Data

Get variant cal data

SOUR:POW:CORR:DATA

Get SourcePowerCalDataEx

Get typed cal data

SOUR:POW:CORR:DATA

Get SourcePowerCalDataScalarEx

Put variant cal data

SOUR:POW:CORR:DATA

Put SourcePowerCalDataEx

Put typed cal data

SOUR:POW:CORR:DATA

Put SourcePowerCalDataScalarEx

Get and Put Custom Measurement Data

Get and Put Custom data

Calc:Data

IArrayTransfer2 Interface

 

Capabilities

Many queries regarding the capability of a specific PNA

SYST:CAPabilities

Capabilities Object

Read installed options

*Opt?

Options

 

Status Commands

Status Registers

GP-IB/Status

 

*OPC;*WAI

GP-IB/Common_Commands

 

 

Events

AllowAllEvents Method

 

app.AllowAllEvents

AllowEventCategory Method

 

app.AllowEventCategory

AllowEventMessage Method

 

app.AllowEventMessage

AllowEventSeverity Method

 

app.AllowEventSeverity

DisallowAllEvents Method

 

app.DisallowAllEvents

MessageText Method

 

app.MessageText

OnCalEvent

 

app.OnCalEvent

OnChannelEvent

 

app.OnChannelEvent

OnDisplayEvent

 

app.OnDisplayEvent

OnHardwareEvent

 

app.OnHardwareEvent

OnMeasurementEvent

 

app.OnMeasurementEvent

OnSCPIEvent

 

app.OnSCPIEvent

OnSystemEvent

 

app.OnSystemEvent

OnUserEvent

 

app.OnUserEvent

SetFailOnOverRange

 

app.SetFailOnOverRange

 

Rear Panel Connector Controls

Material Handler I/O Connector

GP-IB/Control

MaterialHandler IO

Auxiliary IO Connector

GP-IB/Control

Aux IO

External Test Set Connector

GP-IB/Control

External Test Set

 

FIFO Data Buffer (Requires Option 118 or 090)

FIFO ON|OFF

SYST:FIFO[:STATe]

State

Read number of data points

SYST:FIFO:DATA:COUNt?

DataCount

Read data

SYST:FIFO:DATA?

Data

Read data compact form

None

DataInCompactForm

Clear data

SYST:FIFO:DATA:CLEar

Clear

Returns a specific number of bytes to read

SYST:FIFO:DATA:BYTe?

DataAsBytes

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of bytes.

SYST:FIFO:DATA:BYTe:COUNt?

DataByteCount

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of 32-bit floating point (Float32) numbers.

 

DataAsFloat32

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of 16-bit integers.

 

DataAsInt16

Reads the FIFO buffer data as a Variant of a specified array size (SafeArray) of 32-bit integers.

 

DataAsInt32

 

Other N5264A Commands

FastCW

SENS:SWE:TYPE:FACW

FastCWPointCount

Enable Point Averaging

SENS:AVER:MODE

AverageMode

Enable Point Sweep

SENS:SWE:GEN:POINtsweep

PointSweepState

Set Trace Sweep

SENS:SWE:TRIG:MODE

Trigger Mode