Pulse Generator Mode Commands (Option 357)


In this topic:

See Also

- USB PM Mode Commands

- Commands that are Common to All Modes

- Status Registers


Data

Description

Command

Set/query the data format for data transfer

:FORMat:BORDer

Set/query the data format that data is read (binary or ASCii)

:FORMat[:DATA]

Antenna

Description

Command

Sets the antenna orientation

SYSTem:ANTenna:USB:AXIS (SUPERSEDED) is not recommended and has a new recommended behavior:

SYSTem:ANTenna:EMF:AXIS

Import antenna correction factors from USB antenna.

SYSTem:ANTenna:USB:IMPort (SUPERSEDED) is not recommended and has a new recommended behavior:

SYSTem:ANTenna:EMF:IMPort

Import antenna correction factors CSV file for EMF antenna type FSH3D

SYSTem:ANTenna:EMF:IMPort:FILe

Sets antenna type

SYSTem:ANTenna:USB:TYPe (SUPERSEDED) is not recommended and has a new recommended behavior:

SYSTem:ANTenna:EMF:TYPe

Alignments (InstAlign)

Description

Command

Enables Instalign, before the next sweep

[:SENSe]:ALIGnment:AMPLitude:NOW

Align all state (coupled to all individual alignments)

[:SENSe]:ALIGnment:ALL[:STATe]

Align now (coupled to all individual alignments)

[:SENSe]:ALIGnment:AMPLitude:NOW

InstAlign state

[:SENSe]:ALIGnment:AMPLitude[:STATe]

Instrument

Description

Command

Query a file catalog

INSTrument:CATalog?

Enables front panel key press control

INSTrument:GTL

Disables front panel key press control (Lockout)

INSTrument:GTR

Sets the remote lockout message

INSTrument:RLOCkout:DISable

Sets the current mode

INSTrument[:SELect]

Frequency

Description

Command

Set/query frequency mode

SOURce:FREQuency:MODE

Set/query CW frequency

SOURce:FREQuency[:CW]

Average

Description

Command

Number of averages

[:SENSe]:AVERage:COUNt

Set/query the averaging state

[:SENSe]:AVERage[:ENABle]

 

Display

Description

Command

Set/query display brightness

DISPlay:BRIGhtness

Set/query system date format

DISPlay:DATE:FMT

Enables/disables the FieldFox display

DISPlay:ENABle

Set/query keywords for creating filenames

DISPlay:KEYWord[:DATA]

Reset filename keywords to their default values

DISPlay:KEYWord:DEFault

Set/query display mode 

DISPlay:SCREen:GEOMetry

Set/query the formatting of the system time

DISPlay:TIME:FMT

Set/query the FieldFox display data title

DISPlay:TITLe:DATA

Set/query the display title state

DISPlay:TITLe[:STATe]

Calibration

Description

Command

Clear the calibration

[:SENSe]:CORRection:CLEar

Initiate and save the calibration

[:SENSe]:CORRection:COLLect

Cancel calibration

[:SENSe]:CORRection:COLLect:CANCel

Load calibration file

[:SENSe]:CORRection:LOAD

Query calibration status

STATus:QUEStionable:CALibration:CONDition?

Enable calibration status

STATus:QUEStionable:CALibration:ENABle

Query Questionable Calibration Event register

STATus:QUEStionable:CALibration[:EVENt]?

Questionable Calibration Event Register when the bit has a negative transition

STATus:QUEStionable:CALibration:NTRansition

Questionable Calibration Event Register when the bit has a positive transition

STATus:QUEStionable:CALibration:PTRansition

Pulse Generator CW Modulation - ok

Description

Command

Set/query AM depth

SOURce:AM:INTernal[1]|2|:DEPth

Set/query AM rate

SOURce:AM:INTernal[1]|2|:RATe

Select Amplitude Modulation type

SOURce:AM:SELect

Enable/Disable RF source state

SOURce:ENABle[:STATe]

Set/query FM deviation

SOURce:FM:INTernal[1]|2|3|4|:DEViation

Enable/disable frequency tone

SOURce:FM:INTernal[1]|2|3|4|:ENABLe

Set/query FM rate

SOURce:FM:INTernal[1]|2|3|4|:RATe

Set/query FM time interval

SOURce:FM:INTernal[1]|2|3|4|:TIMe[1]|2|[:INTerval]

Select Frequency Modulation type

SOURce:FM:SELect

Set/query frequency mode

SOURce:FREQuency:MODE

Set/query the source power on port 1e

SOURce:POWer[:PORT1|PORT]

Read the measured power port 2

SOURce:POWer:PORT2?

Set/query AM modulation depth for selected pulse N

SOURce:PULM:INTernal[1]|2|3|4|:AM:DEPTh

Set/query AM width for selected pulse N

SOURce:PULM:INTernal[1]|2|3|4|:AM:WIDTh

Export the current built-in pulse item definition to the
user sequence table

SOURce:PULM:INTernal[1]|2|3|4|:EXPort

Set/query FM deviation for selected pulse N

SOURce:PULM:INTernal[1]|2|3|4|:FM[:DEViation]

Set/query pulse rep frequency for selected pulse N. PRF is the reciprocal of PRI

SOURce:PULM:INTernal[1]|2|3|4|:PRF

Set/query pulse rep interval for selected pulse N. PRI is the reciprocal of PRF

SOURce:PULM:INTernal[1]|2|3|4|:PRI

Set/query pulse width on time (between the rising and falling edges) of a single pulse

SOURce:PULM:INTernal[1]|2|3|4|:PWIDth

Set trigger delay value

SOURce:PULM:INTernal[1]|2|3|4|:TRIGger:DELay

Query pulse type

SOURce:PULM:INTernal[1]|2|3|4|:TYPE?

Select pulse type

SOURce:PULM:SELect

Last Modified:

10jun2024

Added new topic (A.13.10)