:LTESt Mask Limit Commands
Instrument:
N1010A
N1000A
DCA-M
Meas. mode:
Scope
Eye
Jitter
TDR
Flex Apps:
FlexDCA
FlexRT
Creating a Eye Mask Limit Test
The following example shows how to create a limit test on eye mask number 3 and run the test until 100 failures have occurred. After the test completes, results are reported:
- Waveform is saved to a file.
- Summary file is created.
- Monochrome screen image of the entire FlexDCA display is saved to a JPG file.
You can create a test for each active eye mask.
:ACQuire:SINGle :LTESt:MTESt:MRESult3:FAILures 100 :LTESt:MTESt:SWAVeform:CHAN1A:STATe DISK :LTESt:MTESt:SWAVeform:CHAN1A:FNAMe "C:\Users\kentb\Documents\Keysight\FlexDCA\Waveforms\Mask Waveform.wfmx" :LTESt:MTESt:SSUMmary:STATe ON :LTESt:MTESt:SSUMmary:FNAMe "C:\Users\kentb\Documents\Keysight\FlexDCA\Limit Summaries\Mask Test 1.sum" :LTESt:MTESt:SIMage:STATe ON :LTESt:MTESt:SIMage:MONochrome ON :LTESt:MTESt:SIMage:WINDow DISPlay :LTESt:MTESt:SIMage:FNAMe "C:\Users\kentb\Documents\Keysight\FlexDCA\Screen Images\Mask.jpg" :LTESt:MTESt:MRESult1:STATe ON :ACQuire:RUN *OPC?