File | Instrument | Response | Stimulus | Utility | Cal | Apps | Remote ONLY
Trace | Channel | Display-Window
Setup | Display-Sheet Setup | Display Setup | External
Devices | External Sources |
Source
Modulation |
PMAR | External DC Source | External
Pulse Generators | New
Measurement | Delete
Measurement | Manage
Meas | Balanced
Meas
Hardware: Interface
Control | External
Test Set | RF
/ IF Path Config |
DSP
(PNA-X)
Description |
SCPI |
COM |
---|---|---|
New Trace |
||
Select Trace |
||
Measure |
||
Trace Title |
||
Add Trace |
||
Delete Trace |
None |
|
Move Trace |
||
Hold Trace |
||
Set/get the number of traces of selected channel |
None |
|
Trace Maximize |
Add |
None |
|
Make Active |
None |
|
Read Channel Number |
||
Read UNUSED channel numbers |
None |
|
Read used channel numbers |
None |
|
Read number of Channels |
None |
|
Copy ONLY mechanical switches and attenuator settings. |
||
Delete a channel |
||
Set and return the group of channels |
None |
|
Set and return the Multi DUT parallel measurement state |
None |
|
Get the information if the parallel measurement is executed in the last sweep |
None |
|
Set up multiple channels for manual trigger |
None |
Select Window |
||
Window Title |
||
Add Window |
||
Delete Window |
None |
|
Move Window |
||
Window Layout |
||
Window Max |
||
Return Window Number(s) |
||
Read the window number of the selected trace |
||
Creates N windows |
None |
|
Feed specified measurement to specified window |
None |
|
Returns the next unused trace number |
None |
|
Set graph divisions |
None |
Select Sheet |
None |
|
Sheet Title |
None |
|
Add Sheet |
None |
|
Delete Sheet |
None |
|
Sheet Layout |
None |
|
Get list of window numbers which the sheet contains |
None |
|
Feed specified window to a sheet |
None |
|
Return active sheet number |
None |
|
Return list of visible sheets |
None |
Trace Status |
None |
|
Y-axis Labels |
None |
|
Show Marker Readout |
||
Large Readout |
||
Readouts Per Trace |
||
Sets the marker readouts to coupled (one combination annotation) or not coupled (one annotation per trace). |
None |
|
Shows the marker readouts only for active trace or for all traces. |
None |
|
Symbol - Triangle, Flag, and Line |
||
Decimal Places - Stimulus and Response |
||
Readout Position - X and Y |
||
Marker Colors |
||
N Trace: Markers |
||
N Trace: Memory Markers |
||
Reset Color |
None |
|
Save Theme |
||
Recall Theme |
||
Reset Theme |
||
Grid Lines - Solid | Dotted |
||
Y-axis Divisions - 2 to 30 |
||
Show Table - None, Marker, Limit, Ripple, and Segment |
||
Toolbar Softkey |
||
Toolbar Hardkey |
||
Toolbar Port Extensions |
||
Toolbar Transform |
||
Toolbar Marker |
||
Toolbar Cal Set Viewer |
None |
|
Active Entry Toolbar |
||
Toolbar Status Bar |
||
Status Bar |
||
Status Bar Clock |
None |
|
Default Colors |
||
Background Colors |
||
Active Background Color |
||
Grid Colors |
||
Active Labels, Grid Frame Colors |
||
Inactive Window Labels Colors |
||
Failed Trace Colors |
||
N Trace: Data and Limits Colors |
||
N Trace: Memory |
||
Display Update |
None |
Adds an external device to the system. |
||
Returns names of all configured devices |
||
Set driver for the external device. |
||
Set type of device. |
||
Configuration path for external device. |
||
Enable or disable communication with device. |
||
Enable/disable an SMU channel. |
||
Sets and returns the name of the External Device. |
None |
|
Activation state of the device. |
||
Time out value for external device. |
||
Remove a device |
||
Save configuration file |
||
Load configuration file |
||
Returns if specified device responds |
Set Dwell per Point |
||
Set Trigger Mode |
||
Set Trigger Port |
||
Set Modulation Control |
None |
Sets and reads the frequency of the arbitrary waveform generator. |
None |
|
Sets and reads the I data for I/Q modulation. |
None |
|
Sets and reads the Q data for I/Q modulation. |
None |
|
Set and read the modulation state. |
None |
|
Checks if pulse source exists. |
None |
|
Turns pulse modulation on and off with an external source. |
None |
|
Sets and reads the maximum number of iterations for an ACP modulation calibration. |
None |
|
Sets and reads the calibration plane for an ACP modulation calibration. |
None |
|
Sets and reads the calibration span for an ACP modulation calibration. |
None |
|
Set and read the ACP modulation calibration state. |
None |
|
Sets and reads the desired ACP calibration tolerance for the ACP modulation calibration. |
None |
|
Sets the Notch location. |
None |
|
Returns a message indicating if the calibration was successful or not. |
None |
|
Sets and reads the maximum number of iterations for a flatness modulation calibration. |
None |
|
Sets and reads the calibration plane for flatness modulation calibration. |
None |
|
Sets and reads the calibration span for a flatness modulation calibration. |
None |
|
Set and read the flatness modulation calibration state. |
None |
|
Sets and reads the desired flatness calibration tolerance for the flatness modulation calibration. |
None |
|
Sets and reads the maximum number of iterations to provide the deepest notch. |
None |
|
Sets and reads the calibration plane for an notch modulation calibration. |
None |
|
Sets and reads the calibration span for a notch modulation calibration. |
None |
|
Set and read the notch modulation calibration state. |
None |
|
Sets and reads the desired notch calibration tolerance for the notch modulation calibration. |
None |
|
Sets and reads the maximum number of iterations for a power modulation calibration. |
None |
|
Sets and reads the calibration plane for a power modulation calibration. |
None |
|
Sets and reads the calibration span for a power modulation calibration. |
None |
|
Set and read the power modulation calibration state. |
None |
|
Sets and reads the desired power calibration tolerance for the power modulation calibration. |
None |
|
Set and read the modulation correction state. |
None |
|
Returns a list of modulation files (*.mdx). |
None |
|
Loads the specified modulation file. |
None |
|
Saves the specified modulation file. |
None |
|
Enables fast calibration. |
None |
Power Meter As Receiver (PMAR) Config See commands to configure and specify a Non- PMAR Power Sensor |
||
Enable use of internal cal factors |
||
Enable min and max freqs |
||
Set Max freq |
||
Set Min freq |
||
Set max number of PM readings |
||
Set tolerance level |
||
Select sensor |
||
Set Cal Factor data |
||
Set Cal Factor frequencies |
||
Set Power loss data |
||
Set Power loss frequencies |
||
Enable Power loss data |
||
Set reference cal factor |
||
Set Zero method |
None |
|
Perform Cal |
None |
|
Returns a list of available power meters that have power uncertainty. |
||
Sets and returns a custom model uncertainty file containing all of the power meter uncertainty properties. |
||
Returns a list of available power meters that have power uncertainty. |
||
Returns the power level for best accuracy. |
||
Returns the power meter reading uncertainty. |
|
|
|
---|---|---|
Correction ON/OFF |
||
Offset correction value. |
||
Scale correction value. |
||
DC Type (Units). |
||
Dwell Before/After Point |
||
Dwell Before Sweep value |
||
Set and return the maximum output current value of the external DC Source |
||
Set and return the maximum output voltage value of the external DC Source |
||
Set and return the DC Meter/DC Source Abort Sweep command |
||
Set and return the DC Meter/DC Source After Sweep command |
||
Set and return the DC Meter/DC Source Before Sweep command |
||
Set and return the DC Meter/DC Source Error Query command |
||
Set and return the DC Meter/DC Source Disable I/O command |
||
Set and return the DC Meter/DC Source ID Query command |
||
Set and return the DC Meter/DC Source Enable I/O command |
||
Set and return the DC Source maximum output |
||
Set and return the DC Source maximum output state |
||
Set and return the DC Source minimum output |
||
Set and return the DC Source minimum output state |
||
Set and return the Point Read commands and Point Set commands |
|
|
|
---|---|---|
PG Names catalog |
||
Read the integer of the name |
Not applicable |
|
Set output channel |
||
Set output Hi amplitude (volts) |
||
Set output Low amplitude (volts) |
||
Set load impedance |
||
Set source impedance |
||
Master Mode |
||
Optional Name/ID argument added to some Pulse gen commands. |
Create S-Parameter Meas. |
||
Create Measurement |
||
Add Measurement |
None |
|
List Measurements |
None |
|
Delete a measurement |
||
Delete ALL measurements |
None |
|
Get a handle to a Trace |
None |
|
Select a Measurement Parameter |
||
Read Channel Number |
||
Read Channel Numbers in use |
None |
|
Read Number of Measurements |
None |
|
Read Measurement Parameter |
None |
|
Set / Read Measurement Name |
||
Read Active Measurement Number |
||
Change Parameter |
||
Returns the Measurement Class name |
||
Read the window number of the selected trace |
None |
|
Read the trace number of the selected trace |
None |
|
Maximize (Isolate) trace |
||
Move a trace to another window |
||
Trace Hold |
||
Trace Hold Clear |
||
Deletes the trace associated with the specified measurement number |
None |
|
Create a new trace in the specified window |
None |
|
Turn the memory trace ON or OFF for the specified measurement |
None |
|
Move a trace associated with measurement number to the specified window |
None |
|
Activate the specified measurement to be selected |
None |
|
Turn trace display associated with the specified measurement ON or OFF |
None |
|
Set or return the title for the specified measurement |
None |
|
Turn the measurement title ON or OFF |
None |
|
Autoscale the specified trace in the specified measurement |
None |
|
Set the Y axis Scale Per Division value of the specified trace associated with the specified measurement |
None |
|
Set the Y axis Reference Level of the specified trace associated with the specified measurement |
None |
|
Set the Reference Position of the specified trace associated with the specified measurement |
None |
|
|
|
Configure Topology |
||
Configure Balanced Measurement |
||
Maps the physical VNA ports to a device of balanced and single-ended logical ports for multi-port systems with greater than 4 ports |
Interface Control ON|OFF |
||
Recall Interface Control file |
Returns a list of currently supported test sets. |
||
Load config file and Restart VNA. |
||
Loads a test set configuration file. (and SCPI only - sets ID value). |
||
Returns the test set model |
||
Returns the test set ID number. |
None |
|
Returns the number of input ports |
None |
|
Switches an input to one of the valid outputs (E5091A only). |
None |
|
Returns the total number of ports on the test set. |
||
Sets and returns the address for the external test set at the specified ID. |
None |
|
Turns ON/OFF the port mapping and control line output. |
||
Sets and returns the port mappings for ALL ports. |
||
Sets and returns the mapping for a single port. |
||
Returns the label on a given channel. |
||
Turns ON/OFF status bar display of test set properties. |
||
Sets the control lines. |
||
Returns the selections available for a given logical port. |
||
Reads a Cal Set for the Test Set model. |
||
Reads a Cal Set for the Port Mapping. |
||
All Sense Multiplexer commands |
||
All Control Multiplexer commands (E5092A only) |
None |
Catalog configuration names |
||
Load a configuration |
||
Store a configuration |
||
Delete a configuration |
||
Read the name of a configuration |
||
Write descriptive text |
||
Catalog all elements |
||
Catalog all settings |
||
Set element |
||
Set value for an element |
||
Read name of current element |
||
RF Path configuration elements / values |
Sets ADC capture mode: auto or manual |
||
Sets and returns method for specifying the way the IF Frequency is determined. |
||
Sets and returns the IF frequency. |
||
Returns the Maximum allowed IFFrequency |
||
Returns the Minimum allowed IFFrequency |
||
Returns errors with manual digital filter settings |
||
Sets digital filter mode. |
||
Sets Stage1Coefficients |
||
Sets Stage1 NCO frequency |
||
Returns the maximum value of any single stage1coefficient. |
||
Returns the maximum number of Stage1 coefficients |
||
Returns the minimum number of Stage1 coefficients |
||
Sets Stage2Coefficients |
||
Returns the maximum value of any single stage2coefficient. |
||
Returns the maximum number of Stage2 coefficients |
||
Returns the minimum number of Stage2 coefficients |
||
Sets and returns stage3 filter type |
||
Returns the names of supported types of Stage3 filters. |
||
Sets and returns the parameter value of the current filter type. |
||
Returns maximum parameter value for the current filter type. |
||
Returns minimum parameter value for the current filter type. |
||
Returns the names of parameters for the current filter type. |