Unguided | SmartCal(Guided) | ECAL | Guided Power Cal | Cal All | Save-Recall | Cal Sets | Cal Types | Prefer's |Correction | Port Ext | Fixturing | CPM | Delta Match | Cal Kits | Standards | Dyn. Uncertainty | Multiple Sensors | Source Pwr Cal | Power Sensors | Receiver Cal | Cal Data | CalPod | Custom Cal Window | AFR
Description |
SCPI See Also: Calibration commands for Apps |
COM |
---|---|---|
Launch Cal Wizard |
||
Set Cal Type |
||
Select a Cal Kit |
||
Get a Handle to the Active Cal Kit |
N/A |
|
Simultaneous 2-Port Calibration |
||
Acquisition Direction |
||
Measure a Standard |
||
Calculate Errors |
||
Do Isolation |
||
Perform and apply Response (Normalization) cal |
Initiate a Guided Cal |
||
List valid Connector Types for a Port |
||
List valid Cal Kits for a Connector type. |
||
Select a Connector Type |
||
Select a Cal Kit |
||
Set cal method for each port pair. |
||
Set Thru Method for each port pair. |
||
Set Thru Port Pairs |
||
Return Number of Steps in a Cal |
||
Return a Description of a Cal Step |
||
Measure a Cal Standard in a Guided Cal |
||
Save Cal |
Adapter settings for Unknown Thru or Adapter Removal |
||
Sets use of a THRU adapter |
None |
|
Set adapter delay |
None |
|
Set adapter description |
None |
|
Set port pairs for adapter |
None |
|
Clear the settings |
None |
|
Return number of adapters |
None |
Auto-Orient ECal |
||
Manual orient ECAL |
||
Read orientation |
||
Calculate Error Terms from a Guided Cal |
||
Computes the error correction terms, turns Correction ON, and saves the calibration to an existing, specified Cal Set |
None |
|
Save Cal to an existing Cal Set GUID |
|
|
Load Eterms during a cal |
|
|
Perform Isolation |
||
Increment Avg for Isolation |
||
Abort Guided cal |
None required. Destroy the GuidedCal object to terminate a cal. |
Use standard Source Power commands to make advanced settings. Use Power Sensor commands to configure the power sensor. |
||
Perform power cal |
||
Power sensor connector type |
||
Cal Kit for power cal |
||
Power Level for cal |
||
Perform match-correction |
||
Load Power Table |
SENS:CORR:COLL:GUID:PSEN:POWTable Used with SMC on mmWave systems. |
Used with SMC on mmWave systems. |
Perform Enhanced Response Cal |
||
Set guided Cal method |
||
Set guided Thru method |
Set preference to not prompt |
||
Read iteration step |
||
Read minimum iterations |
||
Reset iterations |
Specify Module and Characterization |
||
Do ECAL 1-Port |
||
Do ECAL 2-Port |
||
Get ECAL Module Info |
||
Get list of ECal Modules attached to PNA |
||
Get list of characterizations in ECal module |
||
Perform Module Orientation during calibration |
||
Maps ECAL Module to PNA Ports |
||
Reads ECal orientation |
||
Perform ECal Isolation |
||
Increment Avg for ECal Isolation |
Perform User ECal Characterization |
||
Manage PNA Disk Memory Characterizations |
||
Delete disk memory characterizations. |
None |
|
Saves a disk memory characterization to an archive file. |
None |
|
Imports the ECal characterization from the specified archive file. |
None |
|
Reads the user-characterization info from ECal module or PNA disk memory. |
None |
Confidence Check Parameter |
||
Confidence Check Acquire |
||
Confidence Check Done |
||
Sets the state of an ECAL module |
None |
|
Read ECal state data |
None |
|
Read number of ECal states for specified path |
None |
Select the channels to be calibrated. |
||
Set the IFBW |
||
Set the power level |
||
Set the power offset |
||
Set the receiver atten |
||
Set the source atten |
||
Set the User Calset Prefix |
||
Set Path Configuration |
||
Read unique Cal properties |
||
Read unique property values |
||
Set property name/value |
||
Read Cal channel |
N/A |
|
Get GuidedCal handle |
N/A |
|
For each channel, sets the ports to be calibrated. |
||
Returns a final list of ports to be calibrated. |
||
Read generated Cal Sets |
||
Returns available ports for independent power calibration. |
||
Adds a power cal range for a specific port <n>. |
||
Resets all ranges for the given source port <n>. |
||
Queries how many ranges are included in the calibration for source port <n>. |
||
Sets and gets the number of points for range <m> for source port<n>. |
||
Sets and gets the start frequency for range <m> for source port<n>. |
||
Sets and gets the stop frequency for range <m> for source port<n>. |
Recall a Calibration |
||
Apply a Calibration to a measurement |
|
|
Save a Calibration |
||
Save or Recall an Error Term |
||
Read/ Write Cal Set data |
|
|
Apply an Error Term after Uploading |
|
|
Create a Cal Set |
||
Delete a Cal Set |
||
List Cal Sets |
||
List Cal Sets in PNA |
None |
|
Get Cal Set Information |
None |
|
List Cal Set Error Terms |
||
Return if a Cal Set exists |
||
|
|
|
Select a Cal Set by GUID |
||
Apply a Cal Set to a channel |
||
Copy a Cal Set |
||
Save a Cal Set |
||
Save Cal Sets |
None |
|
Automatically save to User Cal Set |
None |
|
Change the Description of a Cal Set |
||
Change the Name of a Cal Set |
||
Recall a Cal File |
||
Save 'in-memory' Cal Set to disk. |
None |
|
Create Cal Set with De-embeded fixture removed. |
||
Create Cal Set with Matching Network included. |
||
Adds stimulus data to a specific buffer. |
None |
|
Returns the stimulus values over which the specific error term was acquired. |
None |
|
Returns FOM stimulus values from a Calset. |
||
Returns the Cal Types from the calset. |
None |
|
Returns the properties of the calset. |
None |
|
Returns the numbers of the channels using the calset. |
None |
|
Unselect Cal Set |
Cal Set Items |
||
Returns names of the items in a cal set |
||
Remove name-value pair from cal set |
None |
|
Read the value of the Cal Set item. |
None |
|
Enumerate name-value pair items in the cal set. |
None |
Catalog ALL Cal Types for the PNA |
||
Catalog Cal Types in the Cal Set |
None |
|
Is a specific Cal Type contained in the Cal Set? |
None |
|
Set and return the measurement Cal Type |
||
Set port to measure QSOLT reflection standards. |
None |
None |
Turn Correction ON|OFF for a channel |
||
Turn Correction ON|OFF for a measurement |
||
Interpolation ON|OFF |
||
Returns the error correction state for the measurement |
Set default Cal Set Save behavior |
||
Sets behavior for simulated cal |
None |
|
External or internal trigger during cal |
||
Set ECal Auto-orient |
||
Set ECal Port Map |
||
Set default Cal Type |
None |
None |
Extensions ON|OFF |
||
Port 1 Extensions Value |
||
Port 2 Extensions Value |
||
Set Freq 1|2 |
||
Set Loss 1|2 |
||
Use 1|2 |
||
Set Loss at DC |
||
Relative Velocity |
||
Port Ext in distance |
||
Set distance units |
||
Set Media per port |
||
Set waveguide cutoff freq per port |
||
Set Velocity Factor per port |
||
Couple to system Velocity Factor |
||
Couple to system Media type |
Auto Port Extensions |
||
Measure OPEN or SHORT for Auto Port Ext. |
||
Sets the frequencies used for Auto Port Ext. calculation. |
||
Include loss correction in Auto Port Ext.? |
||
Include DC Offset in Auto Port Ext.? |
||
Enable specified port for Auto Port Ext.. |
||
Clears old port extension delay and loss data. |
||
Set user span start frequency for Auto Port Ext. |
||
Set user span stop frequency for Auto Port Ext. |
See also Ground Loop De-embedding/Embedding commands |
||
Turn fixturing ON and OFF |
||
Change order of operations |
None |
|
2and 4-port Extrapolate |
||
2-Port Fixturing |
||
Port matching ON and OFF |
||
Reverse ports |
||
Sets Port Matching circuit model. |
||
Sets Port Matching 'S2P' file name. |
||
Sets Capacitance 'C' value. |
||
Sets Conductance 'G' value. |
||
Sets Inductance 'L' value. |
||
Sets Resistance 'R' value. |
||
De-embed ON and OFF |
||
Sets De-embedding circuit model. |
||
Sets De-embedding 'S2P' file name. |
||
Port Impedance ON and OFF |
||
Port Z Real |
||
Port Z Imag |
||
Port Z Real and Imag |
||
4-Port Network Embed/De-embed commands |
||
Specifies the PNA / DUT topology |
||
Specifies the 4-port touchstone file |
||
Embed|De-embed? |
||
Specify PNA port connections |
||
4-port remap |
||
Turn ON or OFF |
||
Differential Port Arbitrary Impedance |
||
Sets the impedance value |
||
Sets real part of impedance |
||
Sets imaginary part of impedance |
||
Turn ON or OFF |
||
Common Mode Port Arbitrary Impedance |
||
Sets the impedance value |
||
Sets real part of impedance |
||
Sets imaginary part of impedance |
||
Turn ON or OFF |
||
Differential Port Matching |
||
Sets type of circuit to embed. |
||
Specifies the 2-port touchstone file |
||
Sets Capacitance value |
||
Sets Conductance value |
||
Sets Inductance value |
||
Sets Resistance value |
||
Turns ON/OFF |
||
Power Compensation |
||
Compensate source power |
||
Remote ONLY |
||
Create Cal Set with De-embeded fixture removed. |
||
Create Cal Set with Matching network included. |
SCPI |
COM |
|
---|---|---|
Characterize a fixture |
||
Creates a single S2P file from two existing files. |
Initiate Cal |
||
Read ports that require Cal |
||
Apply a Cal |
Set a Cal Kit Active |
||
Clear all Cal Kits from PNA |
|
|
Get a Handle to the Active Cal Kit |
|
|
Save All Cal Kits after Modifying |
|
|
Load collection of Kits |
|
|
Load (Recall) All Cal Kits |
|
|
Import a specified kit. |
|
|
Restore Cal Kit Default |
|
|
Restore ALL Cal Kits Default |
|
|
Build a Hybrid Cal Kit |
|
|
Set the Name of a Cal Kit |
||
Set a description of a Cal Kit |
|
|
Get the amount of installed kits |
|
|
Set the Port Label of a Cal Kit |
|
|
Saves a Cal Kit to a file. |
None |
Modify TRL Cal Kit |
||
Set reference plane |
None |
|
Set impedance standard |
None |
|
Set LRL auto-characterization |
None |
Select a Cal Standard |
||
Delete a standard |
|
|
Change description of a standard |
|
|
Assign a Class to a Standard |
||
Set Standard Type |
||
Add connector family name |
|
|
Delete connector family name |
|
|
List connector family names used in a Cal Kit |
|
|
Replace connector family name. |
|
|
Assign connector family name to a standard |
|
|
Set Delay |
||
Set Loss |
||
Set Impedance |
||
Set Max Frequency |
||
Set Min Frequency |
||
Set Label |
||
Set Medium (coax | waveguide) |
||
Set Capacitance (C0 to C3) |
||
Set Inductance (L0 to L3) |
||
Set Arbitrary Impedance (TZReal, TZImag) |
Modify TRL Cal Kit |
||
Set reference plane |
None |
|
Set impedance standard |
None |
|
Set LRL auto-characterization |
None |
Setup Options |
||
Noise Characterization |
||
Clear noise data on specified port |
||
Clear noise data on all ports |
||
Copy noise from a port to all ports |
||
Start Noise char |
List cables |
||
Assign Cable to all ports |
||
Assign Cable to specified port |
||
Reset repeatability |
||
Start Cable char |
Load workspace |
||
Save workspace |
Enabling a Guided Calibration to include Uncertainties |
||
Checkbox on Guided Cal Select Ports page |
Apply to all traces |
None |
None |
Add Trace |
None |
None |
Save uncertainty data |
Enable multiple sensors |
||
Add sensors |
||
Assign power sensor name |
||
Remove sensors |
||
Read the number of configured sensors |
||
Set start freq |
||
Set stop freq |
||
Set connector type |
||
Set Cal Kit |
Copy Source Power cal to another channel |
||
GPIB Power Meter Address |
||
Set source power cal method |
||
Turn correction ON|OFF |
||
Applies correction values after completing a source power cal acquisition sweep. Optionally do reference receiver cal. |
||
Returns the currently-selected power sensor channel (A or B) for use at a specific frequency. |
N/A |
|
Set power level |
||
Set power offset |
||
Set settling tolerance |
||
Set max readings for settling |
||
Set accuracy tolerance |
||
Set max readings for accuracy |
||
Turn ON|OFF display of readings |
||
Acquire receiver-only readings |
||
Initiates a source power cal acquisition. |
||
Aborts a source power cal acquisition sweep that is currently in progress. |
||
Launches the Power Meter Settings dialog on the PNA. |
None |
|
Frequency checking (ON|OFF) |
||
Check test port power |
None |
|
Calibrate the source at multiple power levels. |
None |
None |
See commands to configure a Power Meter as Receiver (PMAR) See commands to configure multiple power sensors for guided Power Cal |
||
Specifies the type of power sensor to be used |
||
Specifies the location of the power sensor to be used. |
||
Returns the ID string of connected USB power meters / sensors. |
||
Pwr meter Max Readings for settling |
||
Pwr meter settling tolerance |
||
Minimum Frequency |
||
Maximum Frequency |
||
Power meter channel |
|
|
Set sensor cal factor |
||
Set table type |
|
|
Read/Write cal data |
||
Use Loss table? |
||
Cal Factor Table |
||
Read number of segments in table |
||
Segment number |
|
|
Add segment |
|
|
Cal factor of the segment |
||
Frequency of the segment |
||
Power Loss Table |
||
Read number of segments in table |
||
Segment number |
|
|
Add segment |
|
|
Frequency |
||
Loss value |
||
Set offset from test port power |
||
Set cal method to receiver cal |
||
Take measurement |
N/A |
|
Turn receiver cal ON | OFF |
||
Do interpolation |
Command used to send other commands as arguments |
None |
|
Start the CalPod software |
None |
|
Assign Calpod serial number to a port. |
None |
|
Unassign Calpod serial number from a port. |
None |
|
Initialize the selected channel |
None |
|
Initialize ALL channels |
None |
|
Recorrect the selected channel |
None |
|
Recorrect ALL channels |
None |
|
Show refresh dialog |
None |
|
Hide refresh dialog |
None |
|
Sets impedance state |
None |
|
Read Calpod temperature |
None |
Turn ON | OFF Custom Cal window. |
||
Show NO Custom Cal windows. |
||
Specify channel to sweep before Cal acquisition. |
||
Sweep NO channel before Cal acquisition. |
||
Preview sweep before remote Cal acquisition. |
Retrieve Cal Data from the PNA |
||
Put Cal Data in the PNA |
Selects whether the fixture is band limited or not. |
None |
|
Selects whether to use DUT correction or not when the characterization fixture is not equal to the DUT measurement fixture. |
None |
|
Selects Fixture Length A not equal to B correction. |
None |
|
Selects Fixture Match A not equal to B correction. |
None |
|
Describes the fixture inputs (single ended or differential). |
None |
|
Selects the number of fixtures to be characterized. |
None |
|
Refreshes preview data. |
None |
|
Reads the impedance profile of the calculated fixture model. |
None |
|
Reads the impedance profile of the calculated fixture model at a specified position. |
None |
|
Chooses the calibration reference Z0 after fixture removal. |
None |
|
Restores the default AFR settings. |
None |
|
Specifies the file paths of saved fixture data. |
None |
|
Assigns the ports for saved fixture data in several formats. |
None |
|
Sets the file type to save fixture data. |
None |
|
Selects all OPEN standards. |
None |
|
Selects all SHORT standards. |
None |
|
Reads the impedance profile of the measured standard. |
None |
|
Reads the impedance of the measured standard at a specified position. |
None |
|
Sets the fixture length for the selected fixture (for 1X AFR only). |
None |
|
Sets the gate position for the selected fixture. |
None |
|
Sets the impedance for the selected term. |
None |
|
Sets the impedance method. |
None |
|
Loads the calibration standards data from a file. |
None |
|
Specifies fixture thru settings. |
None |
|
Chooses the calibration standards. |
None |